Eric C. Hoover
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eric C. Hoover has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
David A. Eddins
Department of Communication Sciences and Disorders, University of South Florida, Tampa
3 shared publications- Frederick J. Gallun
Oregon Hearing Research Center, Oregon Health & Science University, Portland
3 shared publications - Aaron R. Seitz
Department of Psychology, Northeastern University, Boston, MA
1 shared publication Ann C. Eddins
Department of Communication Sciences and Disorders, University of South Florida, 4202 East Fowler Avenue, PCD 1017, Tampa, Florida 32620, USA
1 shared publication- Anna C. Diedesch
Commun. Sci. & Disord., Western Washington Univ., Commun. Sci. & Disord., 516 High St., MS 9171, Bellingham, WA 98225
1 shared publication - Anna Diedesch
Commun. Sci. and Disord., Western Washington Univ., Bellingham, WA
1 shared publication
Latest Publications
- Open Access
- 19 June 2019
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 62 (6) , 2018-2034
A Comparison of Behavioral Methods for Indexing the Auditory Processing of Temporal Fine Structure Cues
Purpose Growing evidence supports the inclusion of perceptual tests that quantify the processing of temporal fine structure (TFS) in clinical hearing assessment. Many tasks have been used to evaluate TFS in the laboratory that vary greatly in the stimuli used and whether the judgments require monaural or binaural comparisons of TFS. The purpose of this study was to compare laboratory measures of TFS for inclusion in a battery of suprathreshold auditory tests. A subset of available TFS tasks were selected on the basis of potential clinical utility and were evaluated using metrics that focus on characteristics important for clinical use. Method TFS measures were implemented in replication of studies that demonstrated clinical utility. Monaural, diotic, and dichotic measures were evaluated in 11 young listeners with normal hearing. Measures included frequency modulation (FM) tasks, harmonic frequency shift detection, interaural phase difference (TFS–low frequency), interaural time difference (ITD), monaural ...
- 19 June 2019
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 62 (6) , 2018-2034
Open AccessA Comparison of Behavioral Methods for Indexing the Auditory Processing of Temporal Fine Structure Cues
Purpose Growing evidence supports the inclusion of perceptual tests that quantify the processing of temporal fine structure (TFS) in clinical hearing assessment. Many tasks have been used to evaluate TFS in the laboratory that vary greatly in the stimuli used and whether the judgments require monaural or binaural comparisons of TFS. The purpose of this study was to compare laboratory measures of TFS for inclusion in a battery of suprathreshold auditory tests. A subset of available TFS tasks were selected on the basis of potential clinical utility and were evaluated using metrics that focus on characteristics important for clinical use. Method TFS measures were implemented in replication of studies that demonstrated clinical utility. Monaural, diotic, and dichotic measures were evaluated in 11 young listeners with normal hearing. Measures included frequency modulation (FM) tasks, harmonic frequency shift detection, interaural phase difference (TFS–low frequency), interaural time difference (ITD), monaural ...
- Open Access
- 1 January 2018
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 33 (1) , 050002
Development and validation of Portable Automated Rapid Testing (PART) measures for auditory research
The current state of consumer-grade electronics means that researchers, clinicians, students, and members of the general public across the globe can create high-quality auditory stimuli using tablet computers, built-in sound hardware, and calibrated consumer-grade headphones. Our laboratories have created a free application that supports this work: PART (Portable Automated Rapid Testing). PART has implemented a range of psychoacoustical tasks including: spatial release from speech-on-speech masking, binaural sensitivity, gap discrimination, temporal modulation, spectral modulation, and spectrotemporal modulation (STM). Here, data from the spatial release and STM tasks are presented. Data were collected across the globe on tablet computers using applications available for free download, built-in sound hardware, and calibrated consumer-grade headphones. Spatial release results were as good or better than those obtained with standard laboratory methods. Spectrotemporal modulation thresholds were obtained rapidly and, for younger normal hearing listeners, were also as good or better than those in the literature. For older hearing impaired listeners, rapid testing resulted in similar thresholds to those reported in the literature. Listeners at five different testing sites produced very similar STM thresholds, despite a variety of testing conditions and calibration routines. Download Spatial Release, PART, and Listen: An Auditory Training Experience for free at https://bgc.ucr.edu/games/.
- 1 January 2018
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 33 (1) , 050002
Open AccessDevelopment and validation of Portable Automated Rapid Testing (PART) measures for auditory research
The current state of consumer-grade electronics means that researchers, clinicians, students, and members of the general public across the globe can create high-quality auditory stimuli using tablet computers, built-in sound hardware, and calibrated consumer-grade headphones. Our laboratories have created a free application that supports this work: PART (Portable Automated Rapid Testing). PART has implemented a range of psychoacoustical tasks including: spatial release from speech-on-speech masking, binaural sensitivity, gap discrimination, temporal modulation, spectral modulation, and spectrotemporal modulation (STM). Here, data from the spatial release and STM tasks are presented. Data were collected across the globe on tablet computers using applications available for free download, built-in sound hardware, and calibrated consumer-grade headphones. Spatial release results were as good or better than those obtained with standard laboratory methods. Spectrotemporal modulation thresholds were obtained rapidly and, for younger normal hearing listeners, were also as good or better than those in the literature. For older hearing impaired listeners, rapid testing resulted in similar thresholds to those reported in the literature. Listeners at five different testing sites produced very similar STM thresholds, despite a variety of testing conditions and calibration routines. Download Spatial Release, PART, and Listen: An Auditory Training Experience for free at https://bgc.ucr.edu/games/.
- 1 January 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (1) , 306-309
Distribution of spectral modulation transfer functions in a young, normal-hearing population
Spectral modulation transfer functions (SMTFs) were measured in 49 young (18–35 years of age) normal-hearing listeners. Noise carriers spanned six octaves from 200 to 12 800 Hz. Sinusoidal (on a log-amplitude scale) spectral modulation with random starting phase was superimposed on the carrier at spectral modulation frequencies of 0.25, 0.5, 1.0, 2.0, 4.0, and 8.0 cycles/octave. Modulation detection thresholds (in dB) yielded SMTFs that were bandpass in nature, consistent with previous investigations reporting data for only a few subjects. Thresholds were notably consistent across subjects despite minimal practice. Population statistics are reported that may serve as reference data for future studies.
- 1 January 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (1) , 306-309
Distribution of spectral modulation transfer functions in a young, normal-hearing population
Spectral modulation transfer functions (SMTFs) were measured in 49 young (18–35 years of age) normal-hearing listeners. Noise carriers spanned six octaves from 200 to 12 800 Hz. Sinusoidal (on a log-amplitude scale) spectral modulation with random starting phase was superimposed on the carrier at spectral modulation frequencies of 0.25, 0.5, 1.0, 2.0, 4.0, and 8.0 cycles/octave. Modulation detection thresholds (in dB) yielded SMTFs that were bandpass in nature, consistent with previous investigations reporting data for only a few subjects. Thresholds were notably consistent across subjects despite minimal practice. Population statistics are reported that may serve as reference data for future studies.
- 1 October 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 142 (4_Suppleme) , 2676-2677
Comparison of scoring methods for spatial release from masking for speech based on analysis of psychometric function slope
The ability to benefit from the spatial separation of talkers in a multi-talker environment is critical to speech communication. A headphone-based test of spatial release from masking for speech (SR2) has been shown to be sensitive to differences between young, healthy listeners and listeners with various auditory deficits. Existing studies relied on a simplistic method to score SR2, comparing the number of correct responses in conditions of collocated and spatially-separated background talkers. Psychometric functions were fit to trial data compiled across multiple studies in order to evaluate if an alternative scoring method could improve diagnostic power. We hypothesized that differences in informational masking between collocated and spatially separated conditions would result in a difference in condition-specific slope estimates, thus leading to a relationship between scoring method and diagnostic power. Results showed a small but significant difference in slope between conditions, consistent with expectations, but the difference between scoring methods was not clinically significant. This information will be used to guide the development of a portable, rapid implementation of SR2 for clinical and research applications. [Funding provided by NIH R01 DC015051.]
- 1 October 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 142 (4_Suppleme) , 2676-2677
Comparison of scoring methods for spatial release from masking for speech based on analysis of psychometric function slope
The ability to benefit from the spatial separation of talkers in a multi-talker environment is critical to speech communication. A headphone-based test of spatial release from masking for speech (SR2) has been shown to be sensitive to differences between young, healthy listeners and listeners with various auditory deficits. Existing studies relied on a simplistic method to score SR2, comparing the number of correct responses in conditions of collocated and spatially-separated background talkers. Psychometric functions were fit to trial data compiled across multiple studies in order to evaluate if an alternative scoring method could improve diagnostic power. We hypothesized that differences in informational masking between collocated and spatially separated conditions would result in a difference in condition-specific slope estimates, thus leading to a relationship between scoring method and diagnostic power. Results showed a small but significant difference in slope between conditions, consistent with expectations, but the difference between scoring methods was not clinically significant. This information will be used to guide the development of a portable, rapid implementation of SR2 for clinical and research applications. [Funding provided by NIH R01 DC015051.]
- 1 April 2017
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 28 (4) , 325-339
Auditory and Cognitive Factors Associated with Speech-in-Noise Complaints following Mild Traumatic Brain Injury
Background:Auditory complaints following mild traumatic brain injury (MTBI) are common, but few studies have addressed the role of auditory temporal processing in speech recognition complaints.Purpose:In this study, deficits understanding speech in a background of speech noise following MTBI were evaluated with the goal of comparing the relative contributions of auditory and nonauditory factors.Research Design:A matched-groups design was used in which a group of listeners with a history of MTBI were compared to a group matched in age and pure-tone thresholds, as well as a control group of young listeners with normal hearing (YNH).Study Sample:Of the 33 listeners who participated in the study, 13 were included in the MTBI group (mean age = 46.7 yr), 11 in the Matched group (mean age = 49 yr), and 9 in the YNH group (mean age = 20.8 yr).Data Collection and Analysis:Speech-in-noise deficits were evaluated using subjective measures as well as monaural word (Words-in-Noise test) and sentence (Quick Speech-in-Noise test) tasks, and a binaural spatial release task. Performance on these measures was compared to psychophysical tasks that evaluate monaural and binaural temporal fine-structure tasks and spectral resolution. Cognitive measures of attention, processing speed, and working memory were evaluated as possible causes of differences between MTBI and Matched groups that might contribute to speech-in-noise perception deficits.Results:A high proportion of listeners in the MTBI group reported difficulty understanding speech in noise (84%) compared to the Matched group (9.1%), and listeners who reported difficulty were more likely to have abnormal results on objective measures of speech in noise. No significant group differences were found between the MTBI and Matched listeners on any of the measures reported, but the number of abnormal tests differed across groups. Regression analysis revealed that a combination of auditory and auditory processing factors contributed to monaural speech-in-noise scores, but the benefit of spatial separation was related to a combination of working memory and peripheral auditory factors across all listeners in the study.Conclusions:The results of this study are consistent with previous findings that a subset of listeners with MTBI has objective auditory deficits. Speech-in-noise performance was related to a combination of auditory and nonauditory factors, confirming the important role of audiology in MTBI rehabilitation. Further research is needed to evaluate the prevalence and causal relationship of auditory deficits following MTBI.
- 1 April 2017
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 28 (4) , 325-339
Auditory and Cognitive Factors Associated with Speech-in-Noise Complaints following Mild Traumatic Brain Injury
Background:Auditory complaints following mild traumatic brain injury (MTBI) are common, but few studies have addressed the role of auditory temporal processing in speech recognition complaints.Purpose:In this study, deficits understanding speech in a background of speech noise following MTBI were evaluated with the goal of comparing the relative contributions of auditory and nonauditory factors.Research Design:A matched-groups design was used in which a group of listeners with a history of MTBI were compared to a group matched in age and pure-tone thresholds, as well as a control group of young listeners with normal hearing (YNH).Study Sample:Of the 33 listeners who participated in the study, 13 were included in the MTBI group (mean age = 46.7 yr), 11 in the Matched group (mean age = 49 yr), and 9 in the YNH group (mean age = 20.8 yr).Data Collection and Analysis:Speech-in-noise deficits were evaluated using subjective measures as well as monaural word (Words-in-Noise test) and sentence (Quick Speech-in-Noise test) tasks, and a binaural spatial release task. Performance on these measures was compared to psychophysical tasks that evaluate monaural and binaural temporal fine-structure tasks and spectral resolution. Cognitive measures of attention, processing speed, and working memory were evaluated as possible causes of differences between MTBI and Matched groups that might contribute to speech-in-noise perception deficits.Results:A high proportion of listeners in the MTBI group reported difficulty understanding speech in noise (84%) compared to the Matched group (9.1%), and listeners who reported difficulty were more likely to have abnormal results on objective measures of speech in noise. No significant group differences were found between the MTBI and Matched listeners on any of the measures reported, but the number of abnormal tests differed across groups. Regression analysis revealed that a combination of auditory and auditory processing factors contributed to monaural speech-in-noise scores, but the benefit of spatial separation was related to a combination of working memory and peripheral auditory factors across all listeners in the study.Conclusions:The results of this study are consistent with previous findings that a subset of listeners with MTBI has objective auditory deficits. Speech-in-noise performance was related to a combination of auditory and nonauditory factors, confirming the important role of audiology in MTBI rehabilitation. Further research is needed to evaluate the prevalence and causal relationship of auditory deficits following MTBI.
- 1 June 2015
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 26 (6) , 540-546
Comparison of Clinical and Traditional Gap Detection Tests
Background:Temporal resolution is important for speech recognition and may contribute to variability in speech recognition among patients. Clinical tests of temporal resolution are available, but it is not clear how closely results of those tests correspond to results of traditional temporal resolution tests.Purpose:The purpose of this study was to compare the Gaps-in-Noise (GIN) test to a traditional measure of gap detection.Study Sample:This study included older adults with hearing loss and younger adults with normal hearing.Data Collection and Analysis:Participants completed one practice and two test blocks of each gap detection test, and a measure of speech-in-noise recognition. Individual data were correlated to examine the relationship between the tests.Results:The GIN and traditional gap detection were significantly, but not highly correlated. The traditional gap detection test contributed to variance in speech recognition in noise, while the GIN did not.Conclusions:The brevity and ease of implementing the GIN in the clinic make it a viable test of temporal resolution. However, it differs from traditional measures in implementation, and as a result relies on different cognitive factors. The GIN thresholds should be interpreted carefully and not presumed to represent an approximation of traditional gap detection thresholds.
- 1 June 2015
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 26 (6) , 540-546
Comparison of Clinical and Traditional Gap Detection Tests
Background:Temporal resolution is important for speech recognition and may contribute to variability in speech recognition among patients. Clinical tests of temporal resolution are available, but it is not clear how closely results of those tests correspond to results of traditional temporal resolution tests.Purpose:The purpose of this study was to compare the Gaps-in-Noise (GIN) test to a traditional measure of gap detection.Study Sample:This study included older adults with hearing loss and younger adults with normal hearing.Data Collection and Analysis:Participants completed one practice and two test blocks of each gap detection test, and a measure of speech-in-noise recognition. Individual data were correlated to examine the relationship between the tests.Results:The GIN and traditional gap detection were significantly, but not highly correlated. The traditional gap detection test contributed to variance in speech recognition in noise, while the GIN did not.Conclusions:The brevity and ease of implementing the GIN in the clinic make it a viable test of temporal resolution. However, it differs from traditional measures in implementation, and as a result relies on different cognitive factors. The GIN thresholds should be interpreted carefully and not presumed to represent an approximation of traditional gap detection thresholds.