SWShilie Weng

Shilie Weng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shilie Weng has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Conjugate Heat Transfer and Thermal Stress Analysis of Film-Cooled Superalloy With Thermal Barrier Coating

    by Xiaohu Chen, Jiao Li, Yun Long, Yuzhang Wang, Shilie Weng, Savas Yavuzkurt

    A conjugate heat transfer study is carried out to obtain temperature and thermal stress field of a film-cooled superalloy with multi-layer thermal barrier coatings (TBCs). The aim is to understand the effects of the blowing ratio and ceramic top coating (TC) thickness on temperature and thermal stress which have an influence on component reliability and life. Results reveal that

  • Open Access

    Building a Modern Energy System in the Yangtze River Delta

    by Shilie Weng, Zhen Huang, Lijun Yu, Xiaomin Xie, Ting You, Tingting Zhang


  • Reliability Assessment Based on Multisource Information Fusion Method for High Pressure Natural Gas Compressors

    by Dengji Zhou, Tingting Wei, Dawen Huang, Maozong Liang, Huisheng Zhang, Shilie Weng, Ping Jiang

    Compressor units used for long-distance transportation natural gas pipeline pressurization have high-pressure and high-risk characteristics. Hence, the scientific reliability assessment is important for high-pressure compressor units, to evaluate the reliability standard, find the performance deficiency, and provide references for operation and maintenance. The classical reliability assessment method is not suitable for the complex and high-reliability equipment, like high-pressure compressor units and pipelines. The reliability assessment of the high-reliability equipment is faced with the challenge of the multisource information. A reliability assessment method based on the multisource information fusion is proposed in this work. The fusion resources consist of design information, component test information, and trial operation information. The reliability of high-pressure compressor units can be assessed by fusing the characteristic parameters, from component-based assessment, function-based assessment, quality evaluation, and life model, by D–S evidence theory. A case study is conducted to verify the proposed reliability assessment method in a 20 MW-class high-pressure compressor. There are four information resources in the case, i.e., component test data, design information, operation data, and simulation data. The compressor reliability is assessed as 99.32%, validated by the statistical assessment result based on long-term shutdown reports. This application points out the existing weakness in the high-pressure compressor units and indicates the directions for improving the design, analysis, operation, and failure prevention technologies. It reveals that the reliability assessment based on multisource information can provide a guarantee for the operation and maintenance of high-pressure compressor units. Meanwhile, the proposed method has good expansibility, which may be used in more fields.


  • Modeling and Operational Optimization Based on Energy Hubs for Complex Energy Networks With Distributed Energy Resources

    by Shixi Ma, Dengji Zhou, Huisheng Zhang, Shilie Weng, Tiemin Shao

    Energy hubs is an integrated system which is capable of transporting, transforming, and storing several types of energy. A number of hubs can be combined as a network and achieve higher efficiency by exchanging information and energy with each other. A decision-making framework for optimal integration of independent small-scale distributed energy systems and traditional large scale combined heating and power (CHP) plants is presented, and an energy supply system with renewable energy resources in Shanghai is cited as a case study. A performance simulation model of this energy network is proposed based on energy hub concept and energy flow between its elements. Furthermore, a novel optimization method named Whales optimization algorithm (WOA) is presented for 24 h operational optimization. A case study is undertaken on a seven-node energy system, including four energy hubs and three load hubs. The results of the case study show that the proposed model and optimization method can improve energy utilization efficiency and reduce system operating costs, even under a system contingency condition.


  • Open Access

    A modified homogenized highly precise direct integration method for time-varying nonhomogeneous systems

    by Shuai Zhu, Jiayuan Zhou, Xiao-Mei Liu, Shi-Lie Weng

    This article investigates a novel method for time-varying systems with an impact term; we call it a modified homogenized highly precise direct integration method. Modified homogenized highly precise direct integration method can deal with the time-varying nonhomogeneous systems effectively by direct integration with high precision. Even though it is often difficult to select the time step size of integration properly for stiff problems, modified homogenized highly precise direct integration method can effectively deal with the this problem with a large time step size. By introducing new variants twice, modified homogenized highly precise direct integration method can easily deal with the nonhomogeneous term by a novel way, inherit the advantages of highly precise direct integration method and avoid the calculation of inverse matrix. The convergency and efficiency analyses are given in this article. Several numerical simulations and an application example are presented to demonstrate the high accuracy, effectiveness and application for engineering problems of modified homogenized highly precise direct integration method.

  • Study on Nonlinear Identification SOFC Temperature Model Based on Particle Swarm Optimization–Least-Squares Support Vector Regression

    by Jinwei Chen, Huisheng Zhang, Shilie Weng

    In order to facilitate valid solid oxide fuel cell (SOFC) temperature control scheme, a nonlinear identification method of SOFC temperature dynamic behaviors is proposed using an autoregressive network with exogenous inputs (NARX) model, whose nonlinear function is described by a least-squares support vector regression (LSSVR) method with radial basis kernel function (RBF). During the identifying process, a particle swarm optimization (PSO) algorithm is introduced to optimize the parameters of LSSVR. On the other hand, a mechanism model is developed to sample the training data to regress the NARX model. Investigations are conducted to analyze the effects of training data size and PSO fitness function on the accuracy of the NARX model. The results demonstrate that the NARX model with tenfold cross-validation fitness function and large size data is precise enough in predicting the SOFC temperature dynamic behaviors. The maximum errors of cathode and anode outlet temperature are 0.3081 K and 0.3293 K, respectively. Furthermore, the simulation speed of NARX model is much faster than the mechanism model because NARX model avoids the internal complex computation process. The training time of the NARX model with large size data is about 1.2 s. For a 20,000 s simulation, the predicting time of the NARX model is about 0.2 s, while the mechanism model is about 36 s. In consideration of its high computational speed and accuracy, NARX model is a powerful candidate for valid multivariable model predictive control (MPC) schemes.


  • Experimental Study on Instability Characteristics of Low-Swirl Flames in a Multinozzle Combustor With Different Swirling Arrays

    by Weijie Liu, Bing Ge, Yinshen Tian, Shusheng Zang, Shilie Weng

    This paper presents experimental study on self-excited combustion instability characteristics of premixed low-swirl flames in a multinozzle can combustor with counterswirl and coswirl arrays. Experiments were carried out over a wide range of inlet velocity from 4 m/s to 15.5 m/s and equivalence ratio from 0.5 to 0.85. Phase-locked OH planar laser-induced fluorescence was employed to measure flame shape and identify heat release rate. Four operation regions: stable combustion region, unstable combustion region, flashback region, and extinguish region are observed for both array burners. The amplitude of pressure fluctuation for counterswirl arrangement is less than the coswirl array, and the stable operating window of the counterswirl array is wider. In the unstable combustion region, the counterswirl flame triggers the 2L mode of the combustion system, while the coswirl flame incites three longitudinal modes with the highest amplitude near 3L. Rayleigh index distribution reveals neighboring flame interaction results in thermoacoustic coupling for multinozzle flames. Additionally, for the counterswirl array, thermoacoustic couplings also exit in the flame base region and shear region while, for the coswirl array, the instability driving zones also locate at the lip region and the tail of center flame which is totally different with counterswirl flame.


  • Open Access

    Modeling and Simulation of IGCC Considering Pressure and Flow Distribution of Gasifier

    by Di Huang, Huisheng Zhang, Shilie Weng, Ming Su

    The integrated gasification combined cycle (IGCC) is a power generation technology which combines clean coal technology with a combined cycle. The system modeling is significant for design, operation and maintenance of the IGCC power plant. However, the previous IGCC modeling methods only contained a simplified compartment gasifier model, which is useful to consider the heat transfer and chemical reaction inside the gasifier, but cannot analyze the pressure and flow distribution. In order to obtain a more accurate model of IGCC system, the volume-resistance technique and modular modeling method are utilized in this paper. The new model can depict the dynamic response and distribution characteristics of the gasifier, as well as their influence on the IGCC system. The simulation result of the gasifier and IGCC system shows an obvious delay after considering pressure and flow distribution. Therefore, the proposed IGCC system model can obtain a more reliable result when considering the distribution characteristics of the gasifier.