Ahmadreza Eslami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmadreza Eslami has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Evan Franklin
School of Engineering, University of Tasmania, Hobart, TAS, Australia
4 shared publications - Michael Negnevitsky
School of Engineering, University of Tasmania, Hobart, TAS, Australia
4 shared publications - Sarah Lyden
University of Tasmania
3 shared publications Mohammad Esmail Hamedani Golshan
Department of Electrical and Computer Engineering; Isfahan University of Technology; Isfahan Iran
1 shared publicationSarah Lyden
1 shared publication- Teymoor Ghanbari
School of Advanced Technologies Shiraz University Shiraz Iran
1 shared publication
Latest Publications
- Open Access
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 195204-195228
Uncertainty-Tolerant Harmonic Meter Placement in Power Systems With High Penetration of Harmonic Sources
In modern power systems, the prevalence of harmonic distortion mandates robust monitoring. Harmonic monitoring faces formidable challenges due to significant uncertainties in measurements, network parameters, and the varying nature of harmonic sources alongside the limited deployment of harmonic meters and inaccessible nodes. A remedy involves the development of potentially uncertain voltage/current pseudo-meters. This paper proposes a novel probabilistic observability method used to estimate harmonic states within defined ranges with a confidence level. Subsequently, network buses are classified into three zones with regard to their harmonic state values being above, below, or uncertain relative to harmonic limits. Leveraging this approach, the number of actual harmonic meters, indicative of monitoring system cost, the bus misclassification index and the probability of misestimating harmonic states considering harmonic limits are minimized. The uncertainties in measurements, network parameters and varying outputs of harmonic sources are addressed. The developed monitoring system is capable of truly identifying buses with harmonic states violating or likely to violate harmonic limits (hot-spots). Demonstrations on IEEE 14-bus test system, IEEE 118-bus test system and the field measurements from the Tasmanian transmission network attest to the method’s efficacy, scalability and generalization capability, while considering high uncertainty in harmonic monitoring with fewer meters than the number of harmonic states. Comparative analysis with other HSE techniques and evaluation of the computational requirements of the proposed method demonstrate both its superiority and robustness. The proposed method provides a promising cost-effective approach for harmonic monitoring in modern power systems with high penetration of distributed harmonic sources.
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 195204-195228
Open AccessUncertainty-Tolerant Harmonic Meter Placement in Power Systems With High Penetration of Harmonic Sources
In modern power systems, the prevalence of harmonic distortion mandates robust monitoring. Harmonic monitoring faces formidable challenges due to significant uncertainties in measurements, network parameters, and the varying nature of harmonic sources alongside the limited deployment of harmonic meters and inaccessible nodes. A remedy involves the development of potentially uncertain voltage/current pseudo-meters. This paper proposes a novel probabilistic observability method used to estimate harmonic states within defined ranges with a confidence level. Subsequently, network buses are classified into three zones with regard to their harmonic state values being above, below, or uncertain relative to harmonic limits. Leveraging this approach, the number of actual harmonic meters, indicative of monitoring system cost, the bus misclassification index and the probability of misestimating harmonic states considering harmonic limits are minimized. The uncertainties in measurements, network parameters and varying outputs of harmonic sources are addressed. The developed monitoring system is capable of truly identifying buses with harmonic states violating or likely to violate harmonic limits (hot-spots). Demonstrations on IEEE 14-bus test system, IEEE 118-bus test system and the field measurements from the Tasmanian transmission network attest to the method’s efficacy, scalability and generalization capability, while considering high uncertainty in harmonic monitoring with fewer meters than the number of harmonic states. Comparative analysis with other HSE techniques and evaluation of the computational requirements of the proposed method demonstrate both its superiority and robustness. The proposed method provides a promising cost-effective approach for harmonic monitoring in modern power systems with high penetration of distributed harmonic sources.
- Open Access
Harmonic Source Location and Characterization Based on Permissible Current Limits by Using Deep Learning and Image Processing
Identification of harmonic sources contributing to harmonic distortion, and characterization of harmonic current injected by them, are crucial tasks in harmonic analysis of modern power systems. In this paper, these tasks are addressed based on the permissible current limits recommended by IEEE 519 Standard, with a determination of whether or not injected harmonics are within these limits. If limits are violated, the extent of the violations are characterized to provide information about harmonic current levels in the power system and facilitate remedial actions if necessary. A novel feature extraction method is proposed, whereby each set of harmonic measurements in a power system are transformed into a unique RGB image. Harmonic State Estimation (HSE) is discretized as a classification problem. Classifiers based on deep learning have been developed to subsequently locate and characterize harmonic sources. The approach has been demonstrated effectively both on the IEEE 14-bus system, and on a real transmission network where harmonics have been measured. A comparative study indicates that the proposed technique outperforms state-of-the-art techniques for HSE, including Bayesian Learning (BL), Singular Value Decomposition (SVD) and hybrid Genetic Algorithm Least Square (GALS) method in terms of accuracy and limited number of monitors.
Open AccessHarmonic Source Location and Characterization Based on Permissible Current Limits by Using Deep Learning and Image Processing
Identification of harmonic sources contributing to harmonic distortion, and characterization of harmonic current injected by them, are crucial tasks in harmonic analysis of modern power systems. In this paper, these tasks are addressed based on the permissible current limits recommended by IEEE 519 Standard, with a determination of whether or not injected harmonics are within these limits. If limits are violated, the extent of the violations are characterized to provide information about harmonic current levels in the power system and facilitate remedial actions if necessary. A novel feature extraction method is proposed, whereby each set of harmonic measurements in a power system are transformed into a unique RGB image. Harmonic State Estimation (HSE) is discretized as a classification problem. Classifiers based on deep learning have been developed to subsequently locate and characterize harmonic sources. The approach has been demonstrated effectively both on the IEEE 14-bus system, and on a real transmission network where harmonics have been measured. A comparative study indicates that the proposed technique outperforms state-of-the-art techniques for HSE, including Bayesian Learning (BL), Singular Value Decomposition (SVD) and hybrid Genetic Algorithm Least Square (GALS) method in terms of accuracy and limited number of monitors.
- Open Access
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 68897-68914
Harmonic Current Estimation of Unmonitored Harmonic Sources With a Novel Oversampling Technique for Limited Datasets
In modern power systems, harmonics are amongst the significant issues attributed to renewable energy sources and nonlinear loads. Direct harmonic monitoring of the entire power system may be too costly or impractical, and measured data could be limited. In this paper, a new methodology is proposed to estimate harmonic current rms values of unmonitored harmonic sources, based on harmonic voltage rms magnitudes only, measured at a limited number of monitored buses. A new technique of output curve-normalization is employed in pre-processing. Subsequently, a method is proposed to refine the architecture of the Artificial Neural Networks’ (ANNs), after which ANN-based harmonic current estimators are developed for each harmonic order and each harmonic source. Furthermore, a novel Neural Oversampling Consensus Algorithm for Regression (NOCAR) is proposed to improve estimation accuracy. K-Nearest Neighbor (KNN) and ANN are combined in developing NOCAR. A comparison is made with state-of-the-art techniques by using synthetic data, which demonstrates both the proposed method’s robustness and its capability to perform when minimal information is available. The implementation for real data demonstrates the efficiency of the ANN-based harmonic current estimators with oversampling. The influence of the number of harmonic meters is investigated, revealing the ability of this data-driven technique to reduce the number of harmonic meters, and hence monitoring costs. Moreover, the correlation between different harmonic orders is studied, with results suggesting that, unlike the widely accepted notion, this correlation should not be ignored in harmonic analysis. This study highlights the advantages of integrating intelligent techniques into harmonic monitoring systems.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 68897-68914
Open AccessHarmonic Current Estimation of Unmonitored Harmonic Sources With a Novel Oversampling Technique for Limited Datasets
In modern power systems, harmonics are amongst the significant issues attributed to renewable energy sources and nonlinear loads. Direct harmonic monitoring of the entire power system may be too costly or impractical, and measured data could be limited. In this paper, a new methodology is proposed to estimate harmonic current rms values of unmonitored harmonic sources, based on harmonic voltage rms magnitudes only, measured at a limited number of monitored buses. A new technique of output curve-normalization is employed in pre-processing. Subsequently, a method is proposed to refine the architecture of the Artificial Neural Networks’ (ANNs), after which ANN-based harmonic current estimators are developed for each harmonic order and each harmonic source. Furthermore, a novel Neural Oversampling Consensus Algorithm for Regression (NOCAR) is proposed to improve estimation accuracy. K-Nearest Neighbor (KNN) and ANN are combined in developing NOCAR. A comparison is made with state-of-the-art techniques by using synthetic data, which demonstrates both the proposed method’s robustness and its capability to perform when minimal information is available. The implementation for real data demonstrates the efficiency of the ANN-based harmonic current estimators with oversampling. The influence of the number of harmonic meters is investigated, revealing the ability of this data-driven technique to reduce the number of harmonic meters, and hence monitoring costs. Moreover, the correlation between different harmonic orders is studied, with results suggesting that, unlike the widely accepted notion, this correlation should not be ignored in harmonic analysis. This study highlights the advantages of integrating intelligent techniques into harmonic monitoring systems.
- 1 February 2022
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 154
Review of AI applications in harmonic analysis in power systems
- 1 February 2022
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 154
Review of AI applications in harmonic analysis in power systems
- Open Access
- 2 February 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (4) , 543-552
New mathematical model from system standpoint to analyse and mitigate PV leakage current of large PV strings/arrays
One of the recently arisen issues for transformerless grid‐connected photovoltaic (PV) systems is high‐frequency leakage current, which flows through the parasitic capacitance of PV system and the neutral grounding resistor (NGR) of the grid. This paper deals with a systemic analysis on the capacitance of large PV systems considering the interconnecting conductors. A new Y‐bus model is proposed to analyse the leakage current of PV strings/arrays of any size in high‐frequency domain. In the model, different capacitances of PV panels and the inductance and capacitance of interconnecting cables are considered. Subsequently, a two‐port circuit is derived by its admittance parameters, which is useful in leakage current studies. In the second step, a novel model for the common mode (CM) analysis of voltage‐source inverters is derived based on which, a new leakage current mitigation technique is proposed which provides capacitive CM paths for both the negative and positive legs of the inverter. The model is assessed using different simulations in various conditions. The results confirm the usefulness of the proposed model.
- 2 February 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (4) , 543-552
Open AccessNew mathematical model from system standpoint to analyse and mitigate PV leakage current of large PV strings/arrays
One of the recently arisen issues for transformerless grid‐connected photovoltaic (PV) systems is high‐frequency leakage current, which flows through the parasitic capacitance of PV system and the neutral grounding resistor (NGR) of the grid. This paper deals with a systemic analysis on the capacitance of large PV systems considering the interconnecting conductors. A new Y‐bus model is proposed to analyse the leakage current of PV strings/arrays of any size in high‐frequency domain. In the model, different capacitances of PV panels and the inductance and capacitance of interconnecting cables are considered. Subsequently, a two‐port circuit is derived by its admittance parameters, which is useful in leakage current studies. In the second step, a novel model for the common mode (CM) analysis of voltage‐source inverters is derived based on which, a new leakage current mitigation technique is proposed which provides capacitive CM paths for both the negative and positive legs of the inverter. The model is assessed using different simulations in various conditions. The results confirm the usefulness of the proposed model.
- 20 November 2017
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 28 (1) , e2478
Index-based voltage dip consideration in optimal planning of SDGs by applying a modified Monte Carlo simulation method
- 20 November 2017
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 28 (1) , e2478
Index-based voltage dip consideration in optimal planning of SDGs by applying a modified Monte Carlo simulation method