Negar Noroozi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Negar Noroozi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Reza Zolghadri
Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
4 shared publications - Mokhtar Yaghoubi
Tehran Iran (the Islamic Republic of)
3 shared publications - Ali Emadi
Department of Electrical and Computer Engineering and McMaster Automotive Resource Centre (MARC), McMaster University, Hamilton, ON L8S 4L8, Canada
2 shared publications - Mehdi Narimani
Department of Electrical and Computer Engineering, McMaster University, Hamilton, Canada
2 shared publications - Ahmed Elezab
High Power Electronics Laboratory (HiPEL), McMaster University, Hamilton, ON, Canada
1 shared publication - Amirreza Poorfakhraei
McMaster University, Department of Electrical and Computer Engineering, Ontario, Canada
1 shared publication
Latest Publications
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (7) , 7173-7182
RMS Current Minimization in a SiC-Based Dual Active Bridge Converter Using Triple-Phase-Shift Modulation
In this article, we propose an optimization approach targeting rms current minimization in a dual active bridge (DAB) converter controlled by triple-phase-shift modulation. The proposed technique overcomes the drawbacks in the existing optimization solutions, namely, the high complexity of the time-domain optimization and the low accuracy of the fundamental harmonic minimization. A finite-component harmonic model is employed in the optimization approach to calculate the current harmonic values in the converter. The total rms current is approximated as the summation of dominant harmonics using the harmonic model. A numerical assessment technique is also proposed in this research that guarantees the accuracy of the adopted harmonic model. The proposed method ensures that the harmonic approximation error is less than a certain level over the operating range. The converter's optimal parameters are calculated through a standard nonlinear optimization procedure. The results are verified in the PLECS simulation environment and experimentally validated on a $5{\rm{\ kW}}$ DAB converter. The prototype input and output voltage ranges are $600{\rm{\ V}} - 800{\rm{\ V}}$ and $200{\rm{\ V}} - 450{\rm{\ V}}$ , respectively.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (7) , 7173-7182
RMS Current Minimization in a SiC-Based Dual Active Bridge Converter Using Triple-Phase-Shift Modulation
In this article, we propose an optimization approach targeting rms current minimization in a dual active bridge (DAB) converter controlled by triple-phase-shift modulation. The proposed technique overcomes the drawbacks in the existing optimization solutions, namely, the high complexity of the time-domain optimization and the low accuracy of the fundamental harmonic minimization. A finite-component harmonic model is employed in the optimization approach to calculate the current harmonic values in the converter. The total rms current is approximated as the summation of dominant harmonics using the harmonic model. A numerical assessment technique is also proposed in this research that guarantees the accuracy of the adopted harmonic model. The proposed method ensures that the harmonic approximation error is less than a certain level over the operating range. The converter's optimal parameters are calculated through a standard nonlinear optimization procedure. The results are verified in the PLECS simulation environment and experimentally validated on a $5{\rm{\ kW}}$ DAB converter. The prototype input and output voltage ranges are $600{\rm{\ V}} - 800{\rm{\ V}}$ and $200{\rm{\ V}} - 450{\rm{\ V}}$ , respectively.
- Open Access
- 8 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Industrial Electronics Society
- Vol. 2, 410-427
Performance Evaluation of Modulation Techniques in Single-Phase Dual Active Bridge Converters
This research presents a thorough comparison of different modulation techniques employed in dual active bridge (DAB) converters. The performance of a DAB converter is essentially affected by the modulation technique and the operating point, including power level, input, and output voltages. A deep understanding of different modulations is required to achieve the highest performance in the entire operating range. Therefore, this paper focuses on comparing different modulation techniques over a DAB converter's operating span. The comparison results provide guidance to apply the correct modulation in certain working areas keeping the converter on top of its performance. Moreover, the paper proposes an optimization solution with distinct objective functions adoptable in DAB converters to reduce power loss. The proposed optimization approach outperforms the existing solutions regarding generality and simplicity. The optimization associates with the modulation techniques that include more than one degree of freedom, such as extended phase shift (EPS) and dual-phase shift (DPS). The proposed optimization and the investigated modulation techniques are evaluated in terms of the converter's efficiency, current stress, and backflow power. The evaluation is realized by the simulation study of a $10{\rm{\,kW}}$ $800{\rm{V}}/500{\rm{V}}$ SiC-based DAB converter in PLECS software.
- 8 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Industrial Electronics Society
- Vol. 2, 410-427
Open AccessPerformance Evaluation of Modulation Techniques in Single-Phase Dual Active Bridge Converters
This research presents a thorough comparison of different modulation techniques employed in dual active bridge (DAB) converters. The performance of a DAB converter is essentially affected by the modulation technique and the operating point, including power level, input, and output voltages. A deep understanding of different modulations is required to achieve the highest performance in the entire operating range. Therefore, this paper focuses on comparing different modulation techniques over a DAB converter's operating span. The comparison results provide guidance to apply the correct modulation in certain working areas keeping the converter on top of its performance. Moreover, the paper proposes an optimization solution with distinct objective functions adoptable in DAB converters to reduce power loss. The proposed optimization approach outperforms the existing solutions regarding generality and simplicity. The optimization associates with the modulation techniques that include more than one degree of freedom, such as extended phase shift (EPS) and dual-phase shift (DPS). The proposed optimization and the investigated modulation techniques are evaluated in terms of the converter's efficiency, current stress, and backflow power. The evaluation is realized by the simulation study of a $10{\rm{\,kW}}$ $800{\rm{V}}/500{\rm{V}}$ SiC-based DAB converter in PLECS software.
- 23 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (1) , 672-682
A Short-Circuit Fault Diagnosis Method for Three-Phase Quasi-Z-Source Inverters
- 23 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (1) , 672-682
A Short-Circuit Fault Diagnosis Method for Three-Phase Quasi-Z-Source Inverters
- 4 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (6) , 5439-5450
A Modulation Method for Leakage Current Reduction in a Three-Phase Grid-Tie Quasi-Z-Source Inverter
The leakage current originated from the fluctuations of the common-mode voltage (CMV) is an issue in a transformerless grid-connected photovoltaic (PV) system. In this paper, a modified space vector modulation based on the Fourier transform analysis is proposed to reduce the leakage current in a three-phase quasi-Z-source inverter (qZSI). The CMV harmonic content in a qZSI contains low and high-frequency harmonics which cause safety and EMI problems respectively. By implementing the proposed modulation in a three-phase qZSI, the low-frequency harmonics of the CMV are mainly reduced. The distribution of the high-frequency harmonics is also modified in a way they can be simply filtered. Passive filtering in a qZSI using other modulation techniques is less effective than using this method. Applying the proposed modulation in the presence of a high-frequency inductive-capacitive filter results in the strong suppression of both high and low-frequency harmonics (more than 90% in the investigated case). A reduced-voltage prototype is designed to evaluate the modulation method. The experimental results from this prototype verify the accuracy of the proposed technique.
- 4 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (6) , 5439-5450
A Modulation Method for Leakage Current Reduction in a Three-Phase Grid-Tie Quasi-Z-Source Inverter
The leakage current originated from the fluctuations of the common-mode voltage (CMV) is an issue in a transformerless grid-connected photovoltaic (PV) system. In this paper, a modified space vector modulation based on the Fourier transform analysis is proposed to reduce the leakage current in a three-phase quasi-Z-source inverter (qZSI). The CMV harmonic content in a qZSI contains low and high-frequency harmonics which cause safety and EMI problems respectively. By implementing the proposed modulation in a three-phase qZSI, the low-frequency harmonics of the CMV are mainly reduced. The distribution of the high-frequency harmonics is also modified in a way they can be simply filtered. Passive filtering in a qZSI using other modulation techniques is less effective than using this method. Applying the proposed modulation in the presence of a high-frequency inductive-capacitive filter results in the strong suppression of both high and low-frequency harmonics (more than 90% in the investigated case). A reduced-voltage prototype is designed to evaluate the modulation method. The experimental results from this prototype verify the accuracy of the proposed technique.
- 21 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (4) , 2847-2856
IGBT Open-Circuit Fault Diagnosis in a Quasi-Z-Source Inverter
In this paper, a fast and practical method is proposed for open-circuit (OC) fault diagnosis (FD) in a three-phase quasi-Z-source inverter (q-ZSI). Compared to the existing fast OC FD techniques in three-phase voltage-source inverters (VSIs), this method is more cost-effective since no ultra-fast processor or high-speed measurement is required. Additionally, the method is independent of the load condition. The proposed method is only applicable to Z-source family inverters and is based on observing the effect of shoot-through (SH) intervals on the system variables during switching periods. The proposed algorithm includes two consecutive stages: OC detection and fault location identification. When both stages of the OC FD algorithm are done, a redundant leg is activated and utilized instead of the failed leg. The accuracy of the proposed method is confirmed by the experimental results from a low-voltage q-ZSI prototype.
- 21 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (4) , 2847-2856
IGBT Open-Circuit Fault Diagnosis in a Quasi-Z-Source Inverter
In this paper, a fast and practical method is proposed for open-circuit (OC) fault diagnosis (FD) in a three-phase quasi-Z-source inverter (q-ZSI). Compared to the existing fast OC FD techniques in three-phase voltage-source inverters (VSIs), this method is more cost-effective since no ultra-fast processor or high-speed measurement is required. Additionally, the method is independent of the load condition. The proposed method is only applicable to Z-source family inverters and is based on observing the effect of shoot-through (SH) intervals on the system variables during switching periods. The proposed algorithm includes two consecutive stages: OC detection and fault location identification. When both stages of the OC FD algorithm are done, a redundant leg is activated and utilized instead of the failed leg. The accuracy of the proposed method is confirmed by the experimental results from a low-voltage q-ZSI prototype.
- 17 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 65 (6) , 4790-4798
Three-Phase Quasi-Z-Source Inverter With Constant Common-Mode Voltage for Photovoltaic Application
In trasformerless grid-connected photovoltaic (PV) systems, common-mode voltage (CMV) fluctuations cause leakage current flow through the stray capacitance of the PV panels. Shoot-through states in a quasi-Z-source inverter (q-ZSI) increase the amplitude of high-order harmonics of CMV. In this paper, by using the modulation technique based on odd pulse width modulation and minor change in the Z network of the three-phase q-ZSI, the leakage current is blocked. No extra semiconductor element is added. By the proposed technique, CMV is kept nearly constant during switching cycles. The experimental results for CMV analysis in a 1 kW prototype are presented to verify the theoretical analysis.
- 17 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 65 (6) , 4790-4798
Three-Phase Quasi-Z-Source Inverter With Constant Common-Mode Voltage for Photovoltaic Application
In trasformerless grid-connected photovoltaic (PV) systems, common-mode voltage (CMV) fluctuations cause leakage current flow through the stray capacitance of the PV panels. Shoot-through states in a quasi-Z-source inverter (q-ZSI) increase the amplitude of high-order harmonics of CMV. In this paper, by using the modulation technique based on odd pulse width modulation and minor change in the Z network of the three-phase q-ZSI, the leakage current is blocked. No extra semiconductor element is added. By the proposed technique, CMV is kept nearly constant during switching cycles. The experimental results for CMV analysis in a 1 kW prototype are presented to verify the theoretical analysis.