Ali Asghar Ghadimi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ali Asghar Ghadimi has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Reza Miveh
AAU Energy, Aalborg University, Aalborg, Denmark
17 shared publications - Francisco Jurado
Department of Electrical Engineering, University of Jaén, 23071 Jaén, Spain
12 shared publications - Mahyar Abasi
Arak University
7 shared publications Mohammad Reza Miveh
Department of Electrical Engineering Tafresh University Tafresh Iran
6 shared publications- Marcos Tostado-Véliz
Department of Electrical Engineering, University of Jaen, 23700 Linares, Spain
5 shared publications - Mohammad Bayat
Department of Electrical Engineering, Faculty of Engineering, Arak University, Arak 38156-8-8349, Iran
5 shared publications
Latest Publications
- Open Access
- 13 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 74123-74140
Detection of Single-Phase Electric Arc Short-Circuit Faults in High-Voltage Transmission Lines Based on the Hilbert Transform
Rapid and reliable detection of single-phase arcing short-circuit faults in high-voltage transmission lines remains a fundamental challenge in power system protection. The unstable and nonlinear behavior of the secondary arc following circuit breaker opening can disrupt the critical automatic reclosing process, while model-based or frequency-domain methods often face limitations in handling the fast dynamics of such faults. This study proposes a novel single-terminal detection framework to address this issue, grounded in precise analysis of the faulted-phase voltage signal. The core methodology relies on the dedicated application of the Hilbert transform, which serves as the foundational tool by constructing an analytic signal in the phase space. This enables accurate, instantaneous computation of the signal’s frequency and envelope energy. The algorithm is structured in six key steps: Following extraction of the raw fault voltage data, the signal is segmented into two consecutive sliding windows after removal of initial switching transients. The Hilbert transform is then applied to the voltage signal, and the total envelope energy of the analytic signal is calculated in each window through integration of the squared magnitude. The varying nature of the envelope energy in arcing faults, contrasted with its relatively constant behavior in solid (metallic) faults, forms the basis for discrimination. From a physical perspective, the proposed indices reflect the transition of the system from the healthy operating state to the arcing fault condition. Under normal operation and in permanent (metallic) faults, the envelope of the analytic voltage signal remains nearly stationary, and its energy stays almost constant in consecutive analysis windows. In contrast, the random ignition and extinction of the electric arc introduce noticeable fluctuations in the voltage waveform, resulting in significant variations in the envelope energy. Accordingly, the proposed indices measure the relative change of the envelope energy between successive windows. To increase the robustness of the method against variations in line voltage and different operating conditions, two normalized indices, namely the relative sensitivity index and the mean-centered index, are introduced, which represent the energy variations in a relative manner. The final decision logic employs a threshold applied to these indices; while this threshold is not entirely independent of all network conditions, its dependence is substantially reduced due to the normalized formulation, allowing a consistent discrimination margin across a wide range of operating scenarios. The proposed method was validated through extensive simulations encompassing single-phase arcing faults with varying arc resistances as well as permanent faults. Sensitivity analysis and simulation results demonstrate that this energy- and instantaneous-frequency-based approach, while maintaining the simplicity of single-ended implementation and eliminating the need for two-terminal communication, achieves significantly higher detection accuracy compared to existing methods. It thereby provides a practical solution to ensure reliable operation of automatic reclosing mechanisms under diverse operating conditions.
- 13 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 74123-74140
Open AccessDetection of Single-Phase Electric Arc Short-Circuit Faults in High-Voltage Transmission Lines Based on the Hilbert Transform
Rapid and reliable detection of single-phase arcing short-circuit faults in high-voltage transmission lines remains a fundamental challenge in power system protection. The unstable and nonlinear behavior of the secondary arc following circuit breaker opening can disrupt the critical automatic reclosing process, while model-based or frequency-domain methods often face limitations in handling the fast dynamics of such faults. This study proposes a novel single-terminal detection framework to address this issue, grounded in precise analysis of the faulted-phase voltage signal. The core methodology relies on the dedicated application of the Hilbert transform, which serves as the foundational tool by constructing an analytic signal in the phase space. This enables accurate, instantaneous computation of the signal’s frequency and envelope energy. The algorithm is structured in six key steps: Following extraction of the raw fault voltage data, the signal is segmented into two consecutive sliding windows after removal of initial switching transients. The Hilbert transform is then applied to the voltage signal, and the total envelope energy of the analytic signal is calculated in each window through integration of the squared magnitude. The varying nature of the envelope energy in arcing faults, contrasted with its relatively constant behavior in solid (metallic) faults, forms the basis for discrimination. From a physical perspective, the proposed indices reflect the transition of the system from the healthy operating state to the arcing fault condition. Under normal operation and in permanent (metallic) faults, the envelope of the analytic voltage signal remains nearly stationary, and its energy stays almost constant in consecutive analysis windows. In contrast, the random ignition and extinction of the electric arc introduce noticeable fluctuations in the voltage waveform, resulting in significant variations in the envelope energy. Accordingly, the proposed indices measure the relative change of the envelope energy between successive windows. To increase the robustness of the method against variations in line voltage and different operating conditions, two normalized indices, namely the relative sensitivity index and the mean-centered index, are introduced, which represent the energy variations in a relative manner. The final decision logic employs a threshold applied to these indices; while this threshold is not entirely independent of all network conditions, its dependence is substantially reduced due to the normalized formulation, allowing a consistent discrimination margin across a wide range of operating scenarios. The proposed method was validated through extensive simulations encompassing single-phase arcing faults with varying arc resistances as well as permanent faults. Sensitivity analysis and simulation results demonstrate that this energy- and instantaneous-frequency-based approach, while maintaining the simplicity of single-ended implementation and eliminating the need for two-terminal communication, achieves significantly higher detection accuracy compared to existing methods. It thereby provides a practical solution to ensure reliable operation of automatic reclosing mechanisms under diverse operating conditions.
- Open Access
- 3 May 2026
- Published by Wiley in Engineering Reports
- Vol. 8 (5) , e70809
Free‐Air Electric Arc Phenomena in High‐Voltage Energy Transmission Systems: A Comprehensive Review Integrating Physical Modeling and Intelligent Monitoring
Reliable detection of free‐air electric arc faults in high‐voltage overhead transmission lines, together with accurate discrimination between transient and permanent faults, is essential for secure single‐phase auto‐reclosing and for maintaining system stability. However, the nonlinear, time‐varying, and environmentally dependent nature of secondary arcs, as well as the influence of shunt reactors, line configuration, and measurement constraints, has led to a fragmented body of literature with no unified analytical map of available detection strategies. This paper presents a systematic and analytical review of the reported methods for free‐air arc‐fault detection in overhead transmission lines. The reviewed studies are classified into three main categories: circuit‐equation‐based methods, signal‐processing‐based methods, and pattern‐recognition/intelligent‐learning‐based methods. For each category, the conceptual basis, required measurements, processing sequence, decision indices, implementation steps, and numerical or experimental limitations are extracted and synthesized. In addition, representative methods are comparatively evaluated using an integrated set of technical and operational criteria, including detection accuracy, response speed, robustness to noise and operating‐condition variation, information requirements, computational burden, and real‐time implementation capability. The results show a clear methodological evolution from physics‐based analytical formulations toward data‐driven and adaptive detection frameworks. Circuit‐equation‐based approaches provide high physical interpretability and direct estimation of arc‐related parameters, but their performance is often constrained by model assumptions, threshold dependence, and multi‐terminal measurement requirements. Signal‐processing‐based methods offer faster and more localized detection by exploiting transient, harmonic, and time–frequency signatures of the arc, although their stability and generalizability may be affected by noise level, parameter tuning, and signal decomposition settings. Intelligent‐learning‐based methods achieve the highest adaptability and classification capability in complex conditions, but they remain strongly dependent on the quality and diversity of training datasets and impose greater computational and implementation burdens. Overall, the review indicates that no single methodological family simultaneously satisfies the full set of protection requirements for modern transmission systems. The main conclusion is that the most promising direction for next‐generation arc‐fault detection lies in hybrid and multi‐layer architectures that combine physical modeling, transient signal analysis, and adaptive intelligent decision‐making within relay‐deployable protection frameworks.
- 3 May 2026
- Published by Wiley in Engineering Reports
- Vol. 8 (5) , e70809
Open AccessFree‐Air Electric Arc Phenomena in High‐Voltage Energy Transmission Systems: A Comprehensive Review Integrating Physical Modeling and Intelligent Monitoring
Reliable detection of free‐air electric arc faults in high‐voltage overhead transmission lines, together with accurate discrimination between transient and permanent faults, is essential for secure single‐phase auto‐reclosing and for maintaining system stability. However, the nonlinear, time‐varying, and environmentally dependent nature of secondary arcs, as well as the influence of shunt reactors, line configuration, and measurement constraints, has led to a fragmented body of literature with no unified analytical map of available detection strategies. This paper presents a systematic and analytical review of the reported methods for free‐air arc‐fault detection in overhead transmission lines. The reviewed studies are classified into three main categories: circuit‐equation‐based methods, signal‐processing‐based methods, and pattern‐recognition/intelligent‐learning‐based methods. For each category, the conceptual basis, required measurements, processing sequence, decision indices, implementation steps, and numerical or experimental limitations are extracted and synthesized. In addition, representative methods are comparatively evaluated using an integrated set of technical and operational criteria, including detection accuracy, response speed, robustness to noise and operating‐condition variation, information requirements, computational burden, and real‐time implementation capability. The results show a clear methodological evolution from physics‐based analytical formulations toward data‐driven and adaptive detection frameworks. Circuit‐equation‐based approaches provide high physical interpretability and direct estimation of arc‐related parameters, but their performance is often constrained by model assumptions, threshold dependence, and multi‐terminal measurement requirements. Signal‐processing‐based methods offer faster and more localized detection by exploiting transient, harmonic, and time–frequency signatures of the arc, although their stability and generalizability may be affected by noise level, parameter tuning, and signal decomposition settings. Intelligent‐learning‐based methods achieve the highest adaptability and classification capability in complex conditions, but they remain strongly dependent on the quality and diversity of training datasets and impose greater computational and implementation burdens. Overall, the review indicates that no single methodological family simultaneously satisfies the full set of protection requirements for modern transmission systems. The main conclusion is that the most promising direction for next‐generation arc‐fault detection lies in hybrid and multi‐layer architectures that combine physical modeling, transient signal analysis, and adaptive intelligent decision‐making within relay‐deployable protection frameworks.
- Open Access
- 13 March 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
Comprehensive review of the requirements of AC transmission grid codes and the role of FACTS devices in integrating renewable power plants
- 13 March 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
Open AccessComprehensive review of the requirements of AC transmission grid codes and the role of FACTS devices in integrating renewable power plants
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 155451-155521
A Comprehensive Review of Flexible Alternating Current Transmission Systems: Topology, Modeling, Formulation, Applications, and Practical Implementation in Real Power Systems
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 155451-155521
Open AccessA Comprehensive Review of Flexible Alternating Current Transmission Systems: Topology, Modeling, Formulation, Applications, and Practical Implementation in Real Power Systems
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Classification of Short‐Circuit Faults in High‐Voltage Transmission Lines Using Energy‐Based and Statistical Indices Extracted From Hilbert and Wavelet Transforms of Three‐Phase Terminal Voltage and Current Signals
Accurate classification of short‐circuit faults in high‐voltage transmission lines, including identification of the faulted phase(s) and determination of ground‐involved or ungrounded faults, is a fundamental component of modern protection schemes. The correctness of fault classification directly influences relay decision‐making, single‐pole tripping strategies, and overall power system reliability. This paper presents a data‐driven, decision‐orientated, single‐terminal method for comprehensive classification of short‐circuit faults, developed based on voltage and current signals measured at one end of the transmission line. The theoretical foundation of the proposed approach relies on the physical principle that the faulted phase(s) exhibit the largest relative amplitude variations, the highest transient energy, and the most pronounced statistical asymmetry in transient signals. Accordingly, by simultaneously employing the Hilbert transform to extract instantaneous amplitude variations and the discrete wavelet transform to obtain transient energy features, a set of closed‐form, normalised, and scale‐independent indices is defined. These indices are then integrated within a hierarchical, rule‐based decision‐making framework. The designed decision logic enables coherent and interpretable detection of fault occurrence, identification of the number of faulted phases, and discrimination between grounded and ungrounded faults. The performance of the proposed method is evaluated through extensive simulations conducted in the MATLAB environment, encompassing both specific case studies and a wide range of general scenarios with variations in fault type, fault location, fault resistance, and network operating conditions. In addition, multiple sensitivity analyses are carried out to assess the robustness and reliability of the algorithm under challenging conditions. The obtained results demonstrate that the proposed algorithm achieves high accuracy, satisfactory robustness, and strong generalisation capability, successfully classifying different types of faults and confirming the effectiveness and validity of the proposed decision‐making framework for protection applications in high‐voltage transmission lines.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Open AccessClassification of Short‐Circuit Faults in High‐Voltage Transmission Lines Using Energy‐Based and Statistical Indices Extracted From Hilbert and Wavelet Transforms of Three‐Phase Terminal Voltage and Current Signals
Accurate classification of short‐circuit faults in high‐voltage transmission lines, including identification of the faulted phase(s) and determination of ground‐involved or ungrounded faults, is a fundamental component of modern protection schemes. The correctness of fault classification directly influences relay decision‐making, single‐pole tripping strategies, and overall power system reliability. This paper presents a data‐driven, decision‐orientated, single‐terminal method for comprehensive classification of short‐circuit faults, developed based on voltage and current signals measured at one end of the transmission line. The theoretical foundation of the proposed approach relies on the physical principle that the faulted phase(s) exhibit the largest relative amplitude variations, the highest transient energy, and the most pronounced statistical asymmetry in transient signals. Accordingly, by simultaneously employing the Hilbert transform to extract instantaneous amplitude variations and the discrete wavelet transform to obtain transient energy features, a set of closed‐form, normalised, and scale‐independent indices is defined. These indices are then integrated within a hierarchical, rule‐based decision‐making framework. The designed decision logic enables coherent and interpretable detection of fault occurrence, identification of the number of faulted phases, and discrimination between grounded and ungrounded faults. The performance of the proposed method is evaluated through extensive simulations conducted in the MATLAB environment, encompassing both specific case studies and a wide range of general scenarios with variations in fault type, fault location, fault resistance, and network operating conditions. In addition, multiple sensitivity analyses are carried out to assess the robustness and reliability of the algorithm under challenging conditions. The obtained results demonstrate that the proposed algorithm achieves high accuracy, satisfactory robustness, and strong generalisation capability, successfully classifying different types of faults and confirming the effectiveness and validity of the proposed decision‐making framework for protection applications in high‐voltage transmission lines.
- Open Access
- 25 October 2025
- Published by Elsevier in Results in Engineering
- Vol. 28
A review of arc in open air modeling: Fundamental concepts, influential parameters, modeling, and software implementation
- 25 October 2025
- Published by Elsevier in Results in Engineering
- Vol. 28
Open AccessA review of arc in open air modeling: Fundamental concepts, influential parameters, modeling, and software implementation
- Open Access
- 5 June 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 169
A generalized superposition-based method for loss allocation in active distribution networks: Introducing effective current concept
- 5 June 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 169
Open AccessA generalized superposition-based method for loss allocation in active distribution networks: Introducing effective current concept
- Open Access
- 1 January 2025
- Published by Wiley in Modelling and Simulation in Engineering
- Vol. 2025 (1)
A New Algorithm for Fault Detection, Classification, and Location Based on the Combination of Time–Frequency Domain Discrete Wavelet and Time–Time Transforms in High‐Voltage Transmission Lines
Recently, the development and progress in the technology and manufacturing of traveling wave relays have caused algorithms based on this method to receive more attention than traditional relay algorithms such as phasor and impedance‐based methods. So far, various researches in the field of comprehensive protection including all three stages of fault detection, classification, and location (FDCL) in high‐voltage transmission lines based on traveling wave theory have been widely published. Most of the published references in this field have worked on each of the stages of comprehensive protection separately, and few references have designed all three stages in the form of an algorithm. Solving them simultaneously in the form of a flowchart has been a major challenge for various reasons in terms of execution time and accuracy of results. On the other hand, references that have solved all three stages in the form of an algorithm have encountered various challenges, including the need for model training data, lack of appropriate accuracy in critical conditions, and high sensitivity to specific conditions. Therefore, in this paper, a comprehensive method for FDCL in high‐voltage transmission lines is presented based on three‐phase voltage signals of both line terminals of the line and also using the unique features of time–time (TT) transform and discrete wavelet transform (DWT) in the form of a flowchart. The proposed method uses the output results of the TT transform to detect the arrival time of the traveling wave caused by the fault to both terminals on both sides of the line, as well as the accurate and detailed coefficients of the fourth level of wavelet transform and predetermined threshold values, to implement the proposed algorithm. The method is implemented in the Simulink/MATLAB software and is programmed in an m‐file of this software. The results obtained from 960 simulated scenarios and eight critical sensitivity analyses demonstrated that the proposed algorithm achieves a fault detection delay of only 0.188 ms, 100% accuracy in faulty phase identification, and an average fault location error of 0.66%. The comparative results with previously reported methods in the literature indicate that the proposed approach provides superior robustness, speed, and accuracy under various operating and noise conditions.
- 1 January 2025
- Published by Wiley in Modelling and Simulation in Engineering
- Vol. 2025 (1)
Open AccessA New Algorithm for Fault Detection, Classification, and Location Based on the Combination of Time–Frequency Domain Discrete Wavelet and Time–Time Transforms in High‐Voltage Transmission Lines
Recently, the development and progress in the technology and manufacturing of traveling wave relays have caused algorithms based on this method to receive more attention than traditional relay algorithms such as phasor and impedance‐based methods. So far, various researches in the field of comprehensive protection including all three stages of fault detection, classification, and location (FDCL) in high‐voltage transmission lines based on traveling wave theory have been widely published. Most of the published references in this field have worked on each of the stages of comprehensive protection separately, and few references have designed all three stages in the form of an algorithm. Solving them simultaneously in the form of a flowchart has been a major challenge for various reasons in terms of execution time and accuracy of results. On the other hand, references that have solved all three stages in the form of an algorithm have encountered various challenges, including the need for model training data, lack of appropriate accuracy in critical conditions, and high sensitivity to specific conditions. Therefore, in this paper, a comprehensive method for FDCL in high‐voltage transmission lines is presented based on three‐phase voltage signals of both line terminals of the line and also using the unique features of time–time (TT) transform and discrete wavelet transform (DWT) in the form of a flowchart. The proposed method uses the output results of the TT transform to detect the arrival time of the traveling wave caused by the fault to both terminals on both sides of the line, as well as the accurate and detailed coefficients of the fourth level of wavelet transform and predetermined threshold values, to implement the proposed algorithm. The method is implemented in the Simulink/MATLAB software and is programmed in an m‐file of this software. The results obtained from 960 simulated scenarios and eight critical sensitivity analyses demonstrated that the proposed algorithm achieves a fault detection delay of only 0.188 ms, 100% accuracy in faulty phase identification, and an average fault location error of 0.66%. The comparative results with previously reported methods in the literature indicate that the proposed approach provides superior robustness, speed, and accuracy under various operating and noise conditions.
- Open Access
- 1 January 2025
- Published by Wiley in International Journal of Energy Research
- Vol. 2025 (1)
Dynamic Reconfiguration of Three‐Phase Unbalanced Active Distribution Networks Considering Peer‐To‐Peer Energy Trading
With the recent expansion of renewable‐based energy resources, the proliferation of transactive energy markets has become imperative to facilitate the necessary frameworks for the active participation of these resources. This paper introduces a peer‐to‐peer (P2P) market for energy exchange among prosumers in unbalanced three‐phase distribution networks. In the proposed framework, the distribution network operator acts as a participant, negotiating with the other participants and ensuring the fulfillment of network technical constraints through network reconfiguration. Since network reconfiguration is a mixed integer programming (MIP) problem, the proposed framework is nonconvex; thus, global equilibrium points are not guaranteed. This paper employs a novel relaxation technique in the alternating direction method of multipliers (ADMM) to convexify the distribution system operator (DSO)’s problem and consequently establish the necessary and sufficient conditions for market equilibrium. The model is implemented on the IEEE 34‐bus system to verify the effectiveness of the proposed model. Results demonstrate that utilizing the proposed method increases the overall market profit, and the ADMM algorithm converges with fewer iterations compared to the scenario without network reconfiguration.
- 1 January 2025
- Published by Wiley in International Journal of Energy Research
- Vol. 2025 (1)
Open AccessDynamic Reconfiguration of Three‐Phase Unbalanced Active Distribution Networks Considering Peer‐To‐Peer Energy Trading
With the recent expansion of renewable‐based energy resources, the proliferation of transactive energy markets has become imperative to facilitate the necessary frameworks for the active participation of these resources. This paper introduces a peer‐to‐peer (P2P) market for energy exchange among prosumers in unbalanced three‐phase distribution networks. In the proposed framework, the distribution network operator acts as a participant, negotiating with the other participants and ensuring the fulfillment of network technical constraints through network reconfiguration. Since network reconfiguration is a mixed integer programming (MIP) problem, the proposed framework is nonconvex; thus, global equilibrium points are not guaranteed. This paper employs a novel relaxation technique in the alternating direction method of multipliers (ADMM) to convexify the distribution system operator (DSO)’s problem and consequently establish the necessary and sufficient conditions for market equilibrium. The model is implemented on the IEEE 34‐bus system to verify the effectiveness of the proposed model. Results demonstrate that utilizing the proposed method increases the overall market profit, and the ADMM algorithm converges with fewer iterations compared to the scenario without network reconfiguration.
- Open Access
- 1 June 2024
- Published by Apex Publishing in Journal of Green Energy Research and Innovation
- Vol. 1 (2) , 15-30
Improving Low Voltage Ride-Through Capability of Doubly-Fed Induction Generator Wind Farms Using Superconducting Fault Current Limiter
Doubly-fed induction generators (DFIGs) are crucial in wind turbines due to their advanced control features and efficient power conversion, but they're vulnerable to grid issues like voltage dips and short circuits. This study explores enhancing DFIGs' low voltage ride-through (LVRT) capabilities using a superconducting fault current limiter (SFCL) system. The SFCL's superconducting coil plays a key role by limiting fault current to stabilize power output, reducing excessive currents during faults, and mitigating voltage fluctuations, protecting the rotor-side converter and gearbox. The research focuses on optimizing the coil's inductance to improve SFCL performance, showing through MATLAB/Simulink simulations that adjusting inductance can lessen rotor current oscillations during short circuits. The results indicate significant enhancements in LVRT capabilities, reducing electrical and mechanical stress on generators and converters, preventing severe voltage drops, and maintaining torque levels. Incorporating an SFCL into DFIG systems greatly increases stability, reliability, and fault tolerance, supporting more wind energy integration.
- 1 June 2024
- Published by Apex Publishing in Journal of Green Energy Research and Innovation
- Vol. 1 (2) , 15-30
Open AccessImproving Low Voltage Ride-Through Capability of Doubly-Fed Induction Generator Wind Farms Using Superconducting Fault Current Limiter
Doubly-fed induction generators (DFIGs) are crucial in wind turbines due to their advanced control features and efficient power conversion, but they're vulnerable to grid issues like voltage dips and short circuits. This study explores enhancing DFIGs' low voltage ride-through (LVRT) capabilities using a superconducting fault current limiter (SFCL) system. The SFCL's superconducting coil plays a key role by limiting fault current to stabilize power output, reducing excessive currents during faults, and mitigating voltage fluctuations, protecting the rotor-side converter and gearbox. The research focuses on optimizing the coil's inductance to improve SFCL performance, showing through MATLAB/Simulink simulations that adjusting inductance can lessen rotor current oscillations during short circuits. The results indicate significant enhancements in LVRT capabilities, reducing electrical and mechanical stress on generators and converters, preventing severe voltage drops, and maintaining torque levels. Incorporating an SFCL into DFIG systems greatly increases stability, reliability, and fault tolerance, supporting more wind energy integration.