TUTrio Pambudi Utomo

Trio Pambudi Utomo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Trio Pambudi Utomo has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Learning-Based System for Automatic Table Tennis Stroke Assessment Using a Racket-Mounted Inertial Measurement Unit

    by Nuryani Nuryani, Aripriharta Aripriharta, Risfendra Risfendra, Trio Pambudi Utomo, Fidele Andrianasoavina Justin Armand, Dafina Nazhifah

    Accurate stroke assessment is essential for table tennis coaching. Traditional methods rely on expert observation or expensive motion-capture systems, which are impractical for daily training. As an alternative, researchers use an Inertial Measurement Unit (IMU) attached to the table tennis racket to measure movement parameters, combined with a learning system. This study presents an automatic stroke assessment system that classifies forehand stroke types (basic, topspin, and push), evaluates player skill level (professional and novice), and scores technique quality (on a 100-point scale) using a single racket-mounted IMU and machine learning models. This study involved 16 players (8 professionals, 8 novices) who performed the three stroke types. Five learning-based models were compared: Long Short-Term Memory (LSTM), one-dimensional Convolutional Neural Network (1D-CNN), a CNN-LSTM hybrid, Random Forest (RF), and Extreme Gradient Boosting (XGBoost). For stroke recognition, all models performed well (94–97% accuracy), with LSTM achieving the best result (97%). For skill classification, performance dropped substantially (66–75% accuracy), reflecting the difficulty of distinguishing skill levels from a single stroke; LSTM again performed best (75%). For technique quality assessment, ensemble methods outperformed deep learning models. Random Forest achieved the best Root Mean Square Error (RMSE) of 7.43 and an R-squared (R²) of 0.742, while XGBoost achieved the lowest Mean Absolute Error (MAE) of 2.79. These findings reveal that model suitability is task-dependent: LSTM excels at classification tasks, whereas ensemble methods are more effective for regression-based quality estimation. This study provides practical guidance for designing wearable, learning-driven coaching systems using minimal sensing configurations.

  • Open Access

    Advancing Non-Cuff Hypertension Detection: Leveraging 1D Convolutional Neural Network and Time Domain Physiological Signals

    by Nuryani Nuryani, Trio Pambudi Utomo, Nurhasan Agung Prabowo, Aripriharta, Muhammad Yazid, Mohtar Yunianto

    Timely identification of hypertension (HT) is crucial for effectively managing and reducing the potential health consequences, including cardiovascular events such as heart attacks and strokes, as well as the development of kidney disease. Traditional cuff-based devices often discourage regular monitoring because they cause discomfort. Furthermore, the lack of symptoms in HT complicates the early detection of this condition. To address these challenges, our study employs a non-cuff methodology that utilizes unprocessed electrocardiogram (ECG) and photoplethysmogram (PPG) signals. We utilize a customized approach to enhance the features of a one-dimensional convolutional neural network (CNN) specifically tailored to optimize timeseries data. In contrast to previous research, our methodology avoids the need for complex signal extraction or transformation techniques. The main goal is to identify the optimal input signals and fine-tune the critical hyperparameters of CNNs. The clinical data underwent analysis, which revealed that the use of an integrated ECG and PPG approach resulted in the highest level of accuracy for detection. Notably, the F1 score achieved an impressive value of 98.88%. When evaluated separately, ECG outperformed PPG. Our study contributes to the advancement of the field by introducing a new approach that combines comfort and high accuracy in the early detection of HT. This method is practical and ensures a patient-friendly experience.


  • Open Access

    Drowsiness detection using heart rate variability analysis based on microcontroller unit

    by Muhammad Hendra, Danang Kurniawan, Riza Vina Chrismiantari, Trio Pambudi Utomo, Nuryani Nuryani


  • Open Access

    Electrocardiogram monitoring system based on Android smartphone and microcontroller unit

    by Ariefah Shalihah, Fahmi Alhafid, Nanda Yudi Shofi Subekti, Trio Pambudi Utomo, Nuryani Nuryani

    Disease of the heart is one of the death main cause in the world. Special attention to prevent more deaths from the heart disease is needed; one of them is early diagnose for heart disease with electrocardiogram (ECG). ECG represent electrical activity of the heart. The heart's electrical activity can be recorded using some electrodes that is placed on certain body's surface. ECG records can be used to determine abnormalities of the heart. We design a ECG monitoring system based on android smartphone and microcontroller unit. The ECG signal is obtained directly from patient using AD8232 module. Then, ECG signal is processed in microcontroller unit. Furthermore, the ECG signal is sent to Android smartphone and displayed in this device. We analyse the abnormalities of the heart using the heart rate from ECG signal. Heart rate is obtained from RR-interval in the ECG which represent the time interval between two detected R peak. We use modified Pan-Tompkins algorithm to detect the peak of R wave. The device that we design give good performance to detect and analyse abnormalities of the heart using heart rate.


  • QT interval measurement using derivative and thresholding process

    by Trio Pambudi Utomo, Nuryani Nuryani

    The aim of this study is to propose a method to measure QT interval of electrocardiogram (ECG). Firstly, in this proposed QT interval measurement, the P-wave and QRS complex of ECG signal is removed to detect the T end. Then, the ECG signal is passed through differentiated process. T end is defined as point where last maximum or minimum differentiated signal reaches the threshold value. Threshold value is variated with 5% (TH1), 10% (TH2), and 50% (TH3) of last maximum or minimum value of differentiated signal. The proposed method is compared to reference measurement that provided by Physionet QT Database. The proposed algorithm has been evaluated using clinical data which is 10 ECG records in the Physionet QT Database. Mean difference of proposed QT interval measurement and reference QT interval measurement are 15.4 ± 25.7 ms for TH1, 18.1 ± 25.7 ms for TH2, and 38.2 ± 25.6 ms for TH3.


  • Open Access

    QRS peak detection for heart rate monitoring on Android smartphone

    by Trio Pambudi Utomo, Nuryani Nuryani, Darmanto

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body's surface of a patient. Patient's heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.