Ajay Bhandari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ajay Bhandari has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Anup Singh
Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India
8 shared publications - Niraj Sinha
Indian Institute of Technology Kanpur
8 shared publications Kartika Chandra Tripathy
Biofluids Research Lab, Department of Mechanical Engineering, Indian Institute of Technology (Indian School of Mines) Dhanbad , Dhanbad 826004, India
5 shared publications- Kartika Chandra Tripathy
Biofluids Research Lab, Department of Mechanical Engineering, Indian Institute of Technology (Indian School of Mines), Dhanbad 826004, India
5 shared publications A. Bansal
Indian Institute of Technology
3 shared publicationsAnkit Bansal
Department of Mechanical and Industrial Engineering, Indian Institute of Technology, Roorkee 247677, India
3 shared publications
Latest Publications
- 10 June 2026
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 9 (4) , 1-13
Effect of Moderate Stenosis on the Upstream and Downstream Flow Patterns in the Internal Carotid Artery—An in vitro Investigation
Narrowing of the internal carotid artery (ICA), known as stenosis, can significantly alter normal blood flow and increase the likelihood of cerebrovascular complications such as ischemic stroke. This study presents an in vitro investigation of flow dynamics in a stenosed ICA. A blood-mimicking fluid (BMF) was circulated through the model, allowing for flow behavior similar to physiological conditions. Flow visualization was achieved using particle streak velocimetry (PSV), a noninvasive optical measurement technique capable of capturing the detailed velocity fields. The axial velocity revealed an interesting phenomenon: the velocity profile became smoother and tended toward a more parabolic shape compared to the nonstenotic case, where the peak typically shifts toward the inner curvature region. However, this asymmetry became less pronounced within the stenotic section. The presence of stenosis introduces an opposing curvature, effectively neutralizing the asymmetric flow distribution. Furthermore, the transverse velocity component (v) was plotted along the axial direction (x) to assess secondary flow behavior. The resulting v versus x plot exhibited clear indications of flow disturbances and recirculation zones downstream of the constriction. These findings demonstrate how stenosis modifies the flow patterns within the ICA, potentially contributing to adverse clinical outcomes. The experimental approach using a blood-mimicking fluid and PSV enables a detailed understanding of hemodynamic behavior in stenosed arteries. Such insights are valuable for advancing diagnostic methods and improving treatment planning in vascular diseases.
- 10 June 2026
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 9 (4) , 1-13
Effect of Moderate Stenosis on the Upstream and Downstream Flow Patterns in the Internal Carotid Artery—An in vitro Investigation
Narrowing of the internal carotid artery (ICA), known as stenosis, can significantly alter normal blood flow and increase the likelihood of cerebrovascular complications such as ischemic stroke. This study presents an in vitro investigation of flow dynamics in a stenosed ICA. A blood-mimicking fluid (BMF) was circulated through the model, allowing for flow behavior similar to physiological conditions. Flow visualization was achieved using particle streak velocimetry (PSV), a noninvasive optical measurement technique capable of capturing the detailed velocity fields. The axial velocity revealed an interesting phenomenon: the velocity profile became smoother and tended toward a more parabolic shape compared to the nonstenotic case, where the peak typically shifts toward the inner curvature region. However, this asymmetry became less pronounced within the stenotic section. The presence of stenosis introduces an opposing curvature, effectively neutralizing the asymmetric flow distribution. Furthermore, the transverse velocity component (v) was plotted along the axial direction (x) to assess secondary flow behavior. The resulting v versus x plot exhibited clear indications of flow disturbances and recirculation zones downstream of the constriction. These findings demonstrate how stenosis modifies the flow patterns within the ICA, potentially contributing to adverse clinical outcomes. The experimental approach using a blood-mimicking fluid and PSV enables a detailed understanding of hemodynamic behavior in stenosed arteries. Such insights are valuable for advancing diagnostic methods and improving treatment planning in vascular diseases.
- 17 December 2025
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 223
Heat and mass transfer investigation concerning drug droplet phase change in nasal drug delivery
- 17 December 2025
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 223
Heat and mass transfer investigation concerning drug droplet phase change in nasal drug delivery
- 2 July 2025
- Published by Springer Nature
- p. 133-143
Micro-Particle Deposition Patterns in the Nasal Cavity with Different Types of Deviations
- 2 July 2025
- Published by Springer Nature
- p. 133-143
Micro-Particle Deposition Patterns in the Nasal Cavity with Different Types of Deviations
- 5 March 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 264, 108706
Targeted drug delivery to the deviated regions of the human nasal cavities: An in silico investigation and in vitro validation
- 5 March 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 264, 108706
Targeted drug delivery to the deviated regions of the human nasal cavities: An in silico investigation and in vitro validation
- 1 September 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (9)
Effect of various septal deviations and corrections on nasal aero and particle dynamics: An in silico and in vitro investigation
Septal deviation causes nasal airway obstruction, necessitating septoplasty. The effectiveness of septoplasty is often assessed using the “Nasal Obstruction Symptom Evaluation (NOSE) score” and “Visual analogue scale (VAS)”; however, success rates remain limited. Studies on post-septoplasty outcomes and challenges for different septal deviations are rare. Septal corrections redistribute airflow, with symptom improvements depending on post-surgical changes. Investigating a post-septoplasty cavity's defense against particulate exposure and changes in particle deposition hotspots is crucial due to potential toxicological challenges. The current study uses patient-specific anatomies to examine airflow and particle deposition in pre- and post-septal correction in S-shaped, C-shaped, and reverse C-shaped septal deviations. Experiments measure pressure drops throughout the nasal cavity using a differential U-tube manometer attached to probes at various sites within three-dimensionally printed transparent nasal models. Additionally, Eulerian–Lagrangian airflow and particle deposition simulations are performed. In vitro results show a significant reduction in total pressure drop, ranging from 3 to 24 Pa between deviated and corrected models, and the nasal valve region is the most susceptible to pressure loss. In silico results reveal a maximum reduction of 50% in flow rate differences and 21% in wall shear stress (WSS) within nasal cavities for corrected cases. Lagrangian simulations show higher particle deposition in anterior regions of deviated cases, with an 82% reduction in particle deposition for the reverse C-shaped model with 10-μm particles, while the C-shaped model with 25-micron particles sees a 10% increase. These findings may help otolaryngologists evaluate post-surgical nasal cavity performance regarding airflow, filtration abilities, and potential toxicological challenges.
- 1 September 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (9)
Effect of various septal deviations and corrections on nasal aero and particle dynamics: An in silico and in vitro investigation
Septal deviation causes nasal airway obstruction, necessitating septoplasty. The effectiveness of septoplasty is often assessed using the “Nasal Obstruction Symptom Evaluation (NOSE) score” and “Visual analogue scale (VAS)”; however, success rates remain limited. Studies on post-septoplasty outcomes and challenges for different septal deviations are rare. Septal corrections redistribute airflow, with symptom improvements depending on post-surgical changes. Investigating a post-septoplasty cavity's defense against particulate exposure and changes in particle deposition hotspots is crucial due to potential toxicological challenges. The current study uses patient-specific anatomies to examine airflow and particle deposition in pre- and post-septal correction in S-shaped, C-shaped, and reverse C-shaped septal deviations. Experiments measure pressure drops throughout the nasal cavity using a differential U-tube manometer attached to probes at various sites within three-dimensionally printed transparent nasal models. Additionally, Eulerian–Lagrangian airflow and particle deposition simulations are performed. In vitro results show a significant reduction in total pressure drop, ranging from 3 to 24 Pa between deviated and corrected models, and the nasal valve region is the most susceptible to pressure loss. In silico results reveal a maximum reduction of 50% in flow rate differences and 21% in wall shear stress (WSS) within nasal cavities for corrected cases. Lagrangian simulations show higher particle deposition in anterior regions of deviated cases, with an 82% reduction in particle deposition for the reverse C-shaped model with 10-μm particles, while the C-shaped model with 25-micron particles sees a 10% increase. These findings may help otolaryngologists evaluate post-surgical nasal cavity performance regarding airflow, filtration abilities, and potential toxicological challenges.
- Open Access
- 12 April 2024
- Published by Springer Nature in npj Systems Biology and Applications
- Vol. 10 (1) , 1-17
Radiopharmaceutical transport in solid tumors via a 3-dimensional image-based spatiotemporal model
Lutetium-177 prostate-specific membrane antigen (177Lu-PSMA)-targeted radiopharmaceutical therapy is a clinically approved treatment for patients with metastatic castration-resistant prostate cancer (mCRPC). Even though common practice reluctantly follows “one size fits all” approach, medical community believes there is significant room for deeper understanding and personalization of radiopharmaceutical therapies. To pursue this aim, we present a 3-dimensional spatiotemporal radiopharmaceutical delivery model based on clinical imaging data to simulate pharmacokinetic of 177Lu-PSMA within the prostate tumors. The model includes interstitial flow, radiopharmaceutical transport in tissues, receptor cycles, association/dissociation with ligands, synthesis of PSMA receptors, receptor recycling, internalization of radiopharmaceuticals, and degradation of receptors and drugs. The model was studied for a range of values for injection amount (100–1000 nmol), receptor density (10–500 nmol•l–1), and recycling rate of receptors (10–4 to 10–1 min–1). Furthermore, injection type, different convection-diffusion-reaction mechanisms, characteristic time scales, and length scales are discussed. The study found that increasing receptor density, ligand amount, and labeled ligands improved radiopharmaceutical uptake in the tumor. A high receptor recycling rate (0.1 min–1) increased radiopharmaceutical concentration by promoting repeated binding to tumor cell receptors. Continuous infusion results in higher radiopharmaceutical concentrations within tumors compared to bolus administration. These insights are crucial for advancing targeted therapy for prostate cancer by understanding the mechanism of radiopharmaceutical distribution in tumors. Furthermore, measures of characteristic length and advection time scale were computed. The presented spatiotemporal tumor transport model can analyze different physiological parameters affecting 177Lu-PSMA delivery.
- 12 April 2024
- Published by Springer Nature in npj Systems Biology and Applications
- Vol. 10 (1) , 1-17
Open AccessRadiopharmaceutical transport in solid tumors via a 3-dimensional image-based spatiotemporal model
Lutetium-177 prostate-specific membrane antigen (177Lu-PSMA)-targeted radiopharmaceutical therapy is a clinically approved treatment for patients with metastatic castration-resistant prostate cancer (mCRPC). Even though common practice reluctantly follows “one size fits all” approach, medical community believes there is significant room for deeper understanding and personalization of radiopharmaceutical therapies. To pursue this aim, we present a 3-dimensional spatiotemporal radiopharmaceutical delivery model based on clinical imaging data to simulate pharmacokinetic of 177Lu-PSMA within the prostate tumors. The model includes interstitial flow, radiopharmaceutical transport in tissues, receptor cycles, association/dissociation with ligands, synthesis of PSMA receptors, receptor recycling, internalization of radiopharmaceuticals, and degradation of receptors and drugs. The model was studied for a range of values for injection amount (100–1000 nmol), receptor density (10–500 nmol•l–1), and recycling rate of receptors (10–4 to 10–1 min–1). Furthermore, injection type, different convection-diffusion-reaction mechanisms, characteristic time scales, and length scales are discussed. The study found that increasing receptor density, ligand amount, and labeled ligands improved radiopharmaceutical uptake in the tumor. A high receptor recycling rate (0.1 min–1) increased radiopharmaceutical concentration by promoting repeated binding to tumor cell receptors. Continuous infusion results in higher radiopharmaceutical concentrations within tumors compared to bolus administration. These insights are crucial for advancing targeted therapy for prostate cancer by understanding the mechanism of radiopharmaceutical distribution in tumors. Furthermore, measures of characteristic length and advection time scale were computed. The presented spatiotemporal tumor transport model can analyze different physiological parameters affecting 177Lu-PSMA delivery.
- 27 February 2024
- Published by Springer Nature
- p. 619-631
Highlighting the Importance of Nasal Air Conditioning in Septoplasty Using Virtual Correction Tools: A Numerical Study
- 27 February 2024
- Published by Springer Nature
- p. 619-631
Highlighting the Importance of Nasal Air Conditioning in Septoplasty Using Virtual Correction Tools: A Numerical Study
- 27 February 2024
- Published by Springer Nature
- p. 797-808
Image-Based Retinal Haemodynamics Simulation of Healthy and Pathological Retinal Vasculature
- 27 February 2024
- Published by Springer Nature
- p. 797-808
Image-Based Retinal Haemodynamics Simulation of Healthy and Pathological Retinal Vasculature
- 15 February 2024
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 23 (3) , 1013-1030
Effect of twisting of intravitreal injections on ocular bio-mechanics: a novel insight to ocular surgery
Although intravitreal (IVT) injections provide several advantages in treating posterior segment eye diseases, several associated challenges remain. The current study uses the finite element method (FEM) to highlight the effect of IVT needle rotation along the insertion axis on the reaction forces and deformation inside the eye. A comparison of the reaction forces at the eye’s key locations has been made with and without rotation. In addition, a sensitivity analysis of various parameters, such as the needle’s angular speed, insertion location, angle, gauge, shape, and intraocular pressure (IOP), has been carried out to delineate the individual parameter’s effect on reaction forces during rotation. Results demonstrate that twisting the needle significantly reduces the reaction forces at the penetration location and throughout the needle travel length, resulting in quicker penetration. Moreover, ocular biomechanics are influenced by needle insertion location, angle, shape, size, and IOP. The reaction forces incurred by the patient may be reduced by using a bevel needle of the higher gauge when inserted close to the normal of the local scleral surface toward the orra serrata within the Pars Plana region. Results obtained from the current study can deepen the understanding of the twisting needle’s interaction with the ocular tissue.
- 15 February 2024
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 23 (3) , 1013-1030
Effect of twisting of intravitreal injections on ocular bio-mechanics: a novel insight to ocular surgery
Although intravitreal (IVT) injections provide several advantages in treating posterior segment eye diseases, several associated challenges remain. The current study uses the finite element method (FEM) to highlight the effect of IVT needle rotation along the insertion axis on the reaction forces and deformation inside the eye. A comparison of the reaction forces at the eye’s key locations has been made with and without rotation. In addition, a sensitivity analysis of various parameters, such as the needle’s angular speed, insertion location, angle, gauge, shape, and intraocular pressure (IOP), has been carried out to delineate the individual parameter’s effect on reaction forces during rotation. Results demonstrate that twisting the needle significantly reduces the reaction forces at the penetration location and throughout the needle travel length, resulting in quicker penetration. Moreover, ocular biomechanics are influenced by needle insertion location, angle, shape, size, and IOP. The reaction forces incurred by the patient may be reduced by using a bevel needle of the higher gauge when inserted close to the normal of the local scleral surface toward the orra serrata within the Pars Plana region. Results obtained from the current study can deepen the understanding of the twisting needle’s interaction with the ocular tissue.