Naoki Asakawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Naoki Asakawa has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Natsuki Kawabata
Material Science Program, Division of Materials and Environments, Graduate School of Science and Technology, Gunma University, Kiryu, Gunma 3768515, Japan
4 shared publications Kunito Fukuda
Division of Molecular Science, Graduate School of Science and Technology, Gunma University, Kiryu, Gunma, Japan
3 shared publicationsTeruo Kanki
Institute of Scientific and Industrial Research, Osaka University, Ibaraki, Osaka 567-0047, Japan
3 shared publications- Teruo Kanki
Osaka University
3 shared publications Sihua Wu
Division of Molecular Science, Graduate School of Science and Technology, Gunma University, Kiryu, Gunma, Japan; State Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing, China
2 shared publications- Yufei Xia
State Key Laboratory of Biopharmaceutical Preparation and Delivery, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, PR China
2 shared publications
Latest Publications
- Open Access
- 15 December 2025
- Published by Copernicus GmbH in Magnetic Resonance
- Vol. 6 (2) , 317-329
Static-gradient NMR imaging for depth-resolved molecular diffusion in amorphous regions in semicrystalline poly(tetrafluoroethylene) film
Understanding spatially heterogeneous molecular diffusion in semicrystalline polymers is critical for elucidating interfacial dynamics in soft materials. This study employs static-gradient nuclear magnetic resonance (NMR) imaging to capture the depth-resolved translational motion of polymer chains in a polytetrafluoroethylene (PTFE) film. By focusing on spin–spin relaxation behavior in amorphous regions near crystalline lamellae, we identify multiple diffusion regimes consistent with Bloch–Torrey analysis. The results reveal that molecular mobility at the substrate interface of PTFE film, immobilized on a glass substrate using epoxy resin, is significantly constrained, likely due to interfacial pinning, while the air-side surface shows signs of enhanced mobility. Our findings highlight the utility of static-gradient field NMR for probing nanoscale dynamical heterogeneity in semicrystalline systems.
- 15 December 2025
- Published by Copernicus GmbH in Magnetic Resonance
- Vol. 6 (2) , 317-329
Open AccessStatic-gradient NMR imaging for depth-resolved molecular diffusion in amorphous regions in semicrystalline poly(tetrafluoroethylene) film
Understanding spatially heterogeneous molecular diffusion in semicrystalline polymers is critical for elucidating interfacial dynamics in soft materials. This study employs static-gradient nuclear magnetic resonance (NMR) imaging to capture the depth-resolved translational motion of polymer chains in a polytetrafluoroethylene (PTFE) film. By focusing on spin–spin relaxation behavior in amorphous regions near crystalline lamellae, we identify multiple diffusion regimes consistent with Bloch–Torrey analysis. The results reveal that molecular mobility at the substrate interface of PTFE film, immobilized on a glass substrate using epoxy resin, is significantly constrained, likely due to interfacial pinning, while the air-side surface shows signs of enhanced mobility. Our findings highlight the utility of static-gradient field NMR for probing nanoscale dynamical heterogeneity in semicrystalline systems.
- Open Access
- 3 November 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-19
Static-Gradient NMR imaging for Depth-Resolved Molecular Diffusion in Amorphous Regions in Semicrystalline PTFE Film
Understanding spatially heterogeneous molecular diffusion in semicrystalline polymers is critical for elucidating interfacial dynamics in soft materials. This study employs static-gradient nuclear magnetic resonance (NMR) imaging to capture depth-resolved translational motion of polymer chains in a polytetrafluoroethylene (PTFE) film. By focusing on spin–spin relaxation behavior in amorphous regions near crystalline lamellae, we identify multiple diffusion regimes consistent with Bloch–Torrey analysis. The results reveal that molecular mobility at the substrate interface is significantly constrained, likely due to interfacial pinning, while the air-side surface shows signs of enhanced mobility. Our findings highlight the utility of static-field-gradient NMR for probing nanoscale dynamical heterogeneity in semicrystalline systems.
- 3 November 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-19
Open AccessStatic-Gradient NMR imaging for Depth-Resolved Molecular Diffusion in Amorphous Regions in Semicrystalline PTFE Film
Understanding spatially heterogeneous molecular diffusion in semicrystalline polymers is critical for elucidating interfacial dynamics in soft materials. This study employs static-gradient nuclear magnetic resonance (NMR) imaging to capture depth-resolved translational motion of polymer chains in a polytetrafluoroethylene (PTFE) film. By focusing on spin–spin relaxation behavior in amorphous regions near crystalline lamellae, we identify multiple diffusion regimes consistent with Bloch–Torrey analysis. The results reveal that molecular mobility at the substrate interface is significantly constrained, likely due to interfacial pinning, while the air-side surface shows signs of enhanced mobility. Our findings highlight the utility of static-field-gradient NMR for probing nanoscale dynamical heterogeneity in semicrystalline systems.
- Open Access
- 9 September 2025
- Published by Wiley in Magnetic Resonance in Chemistry
- Vol. 63 (12) , 1075-1082
Spectral Density Function Analysis Reveals Coupled Relaxation and Resonance Modes in Fluorinated Elastomers: Comparison With Semicrystalline Poly(tetrafluoroethylene)
We reveal contrasting behaviors in molecular motion between the two materials, including the identification of resonance‐enhanced dynamic features in elastomers. We present a depth‐resolved analysis of molecular dynamics in semicrystalline polytetrafluoroethylene (PTFE) and fully amorphous fluorinated elastomer (SIFEL) films using static‐gradient solid‐state 19 F NMR imaging. By measuring spin–lattice relaxation rates ( ) at multiple frequencies and evaluating the corresponding spectral density functions, we reveal distinct dynamic behaviors between the two materials. PTFE exhibits pronounced depth dependence in , indicating enhanced molecular motion near the surface due to a structurally disordered amorphous layer. In contrast, the fluorinated elastomer shows spatially uniform values, reflecting its homogeneous molecular mobility. Notably, the elastomer's spectral density function contains resonance‐like peaks at finite frequencies, suggesting the presence of intrinsic vibrational modes superimposed on stochastic motion. This hybrid dynamic signature, captured through nuclear magnetic resonance (NMR) relaxation, offers a unique fingerprint of the elastomer's viscoelastic behavior. Our results demonstrate that static‐gradient NMR imaging can probe subtle spatial variations in polymer dynamics noninvasively and with high sensitivity, enabling direct comparison between crystalline and amorphous systems. The findings provide new insights into nanoscale surface dynamics and contribute to the development of advanced materials with tailored thermomechanical properties.
- 9 September 2025
- Published by Wiley in Magnetic Resonance in Chemistry
- Vol. 63 (12) , 1075-1082
Open AccessSpectral Density Function Analysis Reveals Coupled Relaxation and Resonance Modes in Fluorinated Elastomers: Comparison With Semicrystalline Poly(tetrafluoroethylene)
We reveal contrasting behaviors in molecular motion between the two materials, including the identification of resonance‐enhanced dynamic features in elastomers. We present a depth‐resolved analysis of molecular dynamics in semicrystalline polytetrafluoroethylene (PTFE) and fully amorphous fluorinated elastomer (SIFEL) films using static‐gradient solid‐state 19 F NMR imaging. By measuring spin–lattice relaxation rates ( ) at multiple frequencies and evaluating the corresponding spectral density functions, we reveal distinct dynamic behaviors between the two materials. PTFE exhibits pronounced depth dependence in , indicating enhanced molecular motion near the surface due to a structurally disordered amorphous layer. In contrast, the fluorinated elastomer shows spatially uniform values, reflecting its homogeneous molecular mobility. Notably, the elastomer's spectral density function contains resonance‐like peaks at finite frequencies, suggesting the presence of intrinsic vibrational modes superimposed on stochastic motion. This hybrid dynamic signature, captured through nuclear magnetic resonance (NMR) relaxation, offers a unique fingerprint of the elastomer's viscoelastic behavior. Our results demonstrate that static‐gradient NMR imaging can probe subtle spatial variations in polymer dynamics noninvasively and with high sensitivity, enabling direct comparison between crystalline and amorphous systems. The findings provide new insights into nanoscale surface dynamics and contribute to the development of advanced materials with tailored thermomechanical properties.
- Open Access
- 16 May 2025
- Published by Wiley in FEBS Open Bio
- Vol. 15 (8) , 1303-1318
Knockout of the mitoribosome rescue factors Ict1 or Mtrfr is viable in zebrafish but not mice: compensatory mechanisms underlying each factor's loss
The mitochondrial translation system contains two ribosome rescue factors, ICT1 and MTRFR (C12orf65), which hydrolyze peptidyl‐tRNA in stalled ribosomes. ICT1 also functions as a ribosomal protein of the mitochondrial large ribosomal subunit (mtLSU) in mice and humans, and its deletion is lethal. In contrast, MTRFR does not share this role. Although loss‐of‐function mutations in MTRFR have been linked to human mitochondrial diseases, data on this association in other vertebrates are lacking. Here, attempts to generate Mtrfr knockout mice were unsuccessful. However, knockout zebrafish lines were successfully generated for both ict1 and mtrfr (ict1−/− and mtrfr−/−). Both knockout lines appeared healthy and fertile. ict1−/−, mtrfr−/−, and wild‐type adult caudal fin cells showed significant differences in mitochondrial morphology. The ict1 deletion affected the network properties more than the number of individuals and networks, whereas the mtrfr deletion exhibited the opposite effect. Additionally, the survival rates of the knockout line larvae were significantly lower than those of the wild‐type larvae under starvation conditions. These results suggest that ict1 and mtrfr are required for survival under specific stress conditions, whereas ict1−/− and mtrfr−/− involve different compensatory mechanisms in response to loss of either factor under nonstress conditions. Ict1 proteins from all teleosts, including zebrafish, lack the N‐terminal mtLSU‐binding motif found in most metazoans, suggesting that Ict1 does not function as a ribosomal protein in teleosts. Thus, Mtrfr may partially compensate for the loss of Ict1. In conclusion, zebrafish appear to exemplify a limited category of vertebrates capable of enduring genetic abnormalities in ict1 or mtrfr.
- 16 May 2025
- Published by Wiley in FEBS Open Bio
- Vol. 15 (8) , 1303-1318
Open AccessKnockout of the mitoribosome rescue factors Ict1 or Mtrfr is viable in zebrafish but not mice: compensatory mechanisms underlying each factor's loss
The mitochondrial translation system contains two ribosome rescue factors, ICT1 and MTRFR (C12orf65), which hydrolyze peptidyl‐tRNA in stalled ribosomes. ICT1 also functions as a ribosomal protein of the mitochondrial large ribosomal subunit (mtLSU) in mice and humans, and its deletion is lethal. In contrast, MTRFR does not share this role. Although loss‐of‐function mutations in MTRFR have been linked to human mitochondrial diseases, data on this association in other vertebrates are lacking. Here, attempts to generate Mtrfr knockout mice were unsuccessful. However, knockout zebrafish lines were successfully generated for both ict1 and mtrfr (ict1−/− and mtrfr−/−). Both knockout lines appeared healthy and fertile. ict1−/−, mtrfr−/−, and wild‐type adult caudal fin cells showed significant differences in mitochondrial morphology. The ict1 deletion affected the network properties more than the number of individuals and networks, whereas the mtrfr deletion exhibited the opposite effect. Additionally, the survival rates of the knockout line larvae were significantly lower than those of the wild‐type larvae under starvation conditions. These results suggest that ict1 and mtrfr are required for survival under specific stress conditions, whereas ict1−/− and mtrfr−/− involve different compensatory mechanisms in response to loss of either factor under nonstress conditions. Ict1 proteins from all teleosts, including zebrafish, lack the N‐terminal mtLSU‐binding motif found in most metazoans, suggesting that Ict1 does not function as a ribosomal protein in teleosts. Thus, Mtrfr may partially compensate for the loss of Ict1. In conclusion, zebrafish appear to exemplify a limited category of vertebrates capable of enduring genetic abnormalities in ict1 or mtrfr.
- 18 November 2024
- Published by American Physical Society (APS) in Physical Review E
- Vol. 110 (5) , 054503
Power spectral density imaging for polymeric films using ex-situ solid-state magnetic resonance with needlelike ferromagnet
An ex-situ solid-state nuclear magnetic resonance (NMR) method employing localized magnetic field gradients generated by a needlelike ferromagnet is described. The depth profiling of a multilayer polymeric film using the proposed method and spin density imaging is successfully acquired. The imaging of the variable-frequency spinlattice relaxation rate in the depth direction reveals differences in the spectral density function for molecular dynamics between the surface and interior of the film. This may be due to the differences in the correlation time distribution of the molecular dynamics between the surfaces and interior of the film.
- 18 November 2024
- Published by American Physical Society (APS) in Physical Review E
- Vol. 110 (5) , 054503
Power spectral density imaging for polymeric films using ex-situ solid-state magnetic resonance with needlelike ferromagnet
An ex-situ solid-state nuclear magnetic resonance (NMR) method employing localized magnetic field gradients generated by a needlelike ferromagnet is described. The depth profiling of a multilayer polymeric film using the proposed method and spin density imaging is successfully acquired. The imaging of the variable-frequency spinlattice relaxation rate in the depth direction reveals differences in the spectral density function for molecular dynamics between the surface and interior of the film. This may be due to the differences in the correlation time distribution of the molecular dynamics between the surfaces and interior of the film.
- 22 July 2024
- Published by Elsevier in Journal of Ethnopharmacology
- Vol. 335, 118612
Ecliptasaponin A protects heart against acute ischemia-induced myocardial injury by inhibition of the HMGB1/TLR4/NF-κB pathway
- 22 July 2024
- Published by Elsevier in Journal of Ethnopharmacology
- Vol. 335, 118612
Ecliptasaponin A protects heart against acute ischemia-induced myocardial injury by inhibition of the HMGB1/TLR4/NF-κB pathway
- 24 May 2024
- Published by Elsevier in Particuology
- Vol. 92, 224-233
Engineering W/O/W pickering emulsion for the enhanced antigen delivery and immune responses
- 24 May 2024
- Published by Elsevier in Particuology
- Vol. 92, 224-233
Engineering W/O/W pickering emulsion for the enhanced antigen delivery and immune responses
- Open Access
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
Scanning ex situ solid-state magnetic resonance imaging on polymeric films using a static magnetic field gradient by an electromagnet
A new technique for ex situ solid-state nuclear magnetic resonance imaging of polymeric films has been developed. This method uses the static magnetic field gradient generated by a water-cooled copper electromagnet. The imaging process involves scanning the sample in the plane of the film under a static magnetic field gradient. Two-dimensional (2D) 19F MRI measurements are attempted, where the fast Fourier transform (FFT) spectra of the second half of a Hahn echo peak is used for the depth (X-axis) direction, and the sample film is mechanically moved for the Y-axis, which is in-plane with respect to the film surface and normal to the inter-magnetic-pole line (Z-axis). The sample is a poly(tetrafluoroethylene) [PTFE] film with carved stripes on its surface. Furthermore, three-dimensional (3D) measurements of the film surface and thickness orientations were also performed for an analogous PTFE film. For 2D profiling on the film surface, 2D sample-moving was used. For depth profiling, FFT spectrum analysis was undertaken for each voxel situated at a specific (Y, Z) coordinate within the film. As a result, a 3D image of the sample and its corresponding geometry were obtained, although the scanning area was restricted to a part of the sample. Finally, numerical simulations of the spatial distribution of the static magnetic field were performed to confirm the validity of the present method.
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
Open AccessScanning ex situ solid-state magnetic resonance imaging on polymeric films using a static magnetic field gradient by an electromagnet
A new technique for ex situ solid-state nuclear magnetic resonance imaging of polymeric films has been developed. This method uses the static magnetic field gradient generated by a water-cooled copper electromagnet. The imaging process involves scanning the sample in the plane of the film under a static magnetic field gradient. Two-dimensional (2D) 19F MRI measurements are attempted, where the fast Fourier transform (FFT) spectra of the second half of a Hahn echo peak is used for the depth (X-axis) direction, and the sample film is mechanically moved for the Y-axis, which is in-plane with respect to the film surface and normal to the inter-magnetic-pole line (Z-axis). The sample is a poly(tetrafluoroethylene) [PTFE] film with carved stripes on its surface. Furthermore, three-dimensional (3D) measurements of the film surface and thickness orientations were also performed for an analogous PTFE film. For 2D profiling on the film surface, 2D sample-moving was used. For depth profiling, FFT spectrum analysis was undertaken for each voxel situated at a specific (Y, Z) coordinate within the film. As a result, a 3D image of the sample and its corresponding geometry were obtained, although the scanning area was restricted to a part of the sample. Finally, numerical simulations of the spatial distribution of the static magnetic field were performed to confirm the validity of the present method.
- Open Access
Stochastic Resonance in Organic Electronic Devices
Stochastic Resonance (SR) is a phenomenon in which noise improves the performance of a system. With the addition of noise, a weak input signal to a nonlinear system, which may exceed its threshold, is transformed into an output signal. In the other words, noise-driven signal transfer is achieved. SR has been observed in nonlinear response systems, such as biological and artificial systems, and this review will focus mainly on examples of previous studies of mathematical models and experimental realization of SR using poly(hexylthiophene)-based organic field-effect transistors (OFETs). This phenomenon may contribute to signal processing with low energy consumption. However, the generation of SR requires a noise source. Therefore, the focus is on OFETs using materials such as organic materials with unstable electrical properties and critical elements due to unidirectional signal transmission, such as neural synapses. It has been reported that SR can be observed in OFETs by application of external noise. However, SR does not occur under conditions where the input signal exceeds the OFET threshold without external noise. Here, we present an example of a study that analyzes the behavior of SR in OFET systems and explain how SR can be made observable. At the same time, the role of internal noise in OFETs will be explained.
Open AccessStochastic Resonance in Organic Electronic Devices
Stochastic Resonance (SR) is a phenomenon in which noise improves the performance of a system. With the addition of noise, a weak input signal to a nonlinear system, which may exceed its threshold, is transformed into an output signal. In the other words, noise-driven signal transfer is achieved. SR has been observed in nonlinear response systems, such as biological and artificial systems, and this review will focus mainly on examples of previous studies of mathematical models and experimental realization of SR using poly(hexylthiophene)-based organic field-effect transistors (OFETs). This phenomenon may contribute to signal processing with low energy consumption. However, the generation of SR requires a noise source. Therefore, the focus is on OFETs using materials such as organic materials with unstable electrical properties and critical elements due to unidirectional signal transmission, such as neural synapses. It has been reported that SR can be observed in OFETs by application of external noise. However, SR does not occur under conditions where the input signal exceeds the OFET threshold without external noise. Here, we present an example of a study that analyzes the behavior of SR in OFET systems and explain how SR can be made observable. At the same time, the role of internal noise in OFETs will be explained.