Wonkyu Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wonkyu Choi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ji-Hoon Bae
Department of Computer Education, Korea National University of Education, Cheongju-si 28173, Republic of Korea
5 shared publications - Chan-Won Park
Autonomous IoT Research Section/Intelligent Convergence Research Laboratory, Electronics and Telecommunications Research Institute, Daejeon, Republic of Korea
2 shared publications Chan‐Won Park
Electronics and Telecommunications Research Institute (ETRI) 218 Gajeong‐ro, Yuseong‐gu Daejeon 34129 Republic of Korea
2 shared publications- Cheol-Sig Pyo
Department of KSB Convergence Research, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea
2 shared publications Bomson Lee
Department of Electronics and Radio Engineering College of Electronics and Information Kyung Hee University Global Campus, 1732, Deogyeong‐daero, Giheung‐gu Gyeonggi‐do Yongin‐si 17104 Republic of Korea
1 shared publicationCheolsig Pyo
USN/IoT Convergence Research Department, Electronics and Telecommunications Research Institute (ETRI), Yuseong‐gu, Daejeon 305‐700, Korea
1 shared publication
Latest Publications
- Open Access
Arc-Fault Detection Using Stage-Wise Alignment and Feature Fusion of Dual Learnable Time–Frequency Representations
Arc faults in low-voltage smart-farm distribution systems are difficult to detect reliably because normal current waveforms vary with load composition and operating conditions. This paper presents a progressive three-stage time–frequency learning framework that identifies series arc faults directly from normalized current waveforms. In Stage I, fast Fourier transform (FFT)-based and wavelet-based learnable front-ends independently learn complementary global spectral and local transient representations. In Stage II, their representation spaces are structured using supervised contrastive learning with view-level and cross-spectrum alignment. In Stage III, the aligned feature extractors are frozen, and only the feature fusion block and final classifier are trained for 10-class classification. Current signals are acquired from a practical smart-farm distribution system and evaluated using a measurement-session-level group-wise split. The framework achieves 99.92% accuracy and 99.93% macro recall while maintaining 1.06 M parameters and a model-only inference latency of 8.70 ms. The results demonstrate that the proposed framework provides robust discrimination across unseen measurement sessions within the evaluated load categories and operating conditions.
Open AccessArc-Fault Detection Using Stage-Wise Alignment and Feature Fusion of Dual Learnable Time–Frequency Representations
Arc faults in low-voltage smart-farm distribution systems are difficult to detect reliably because normal current waveforms vary with load composition and operating conditions. This paper presents a progressive three-stage time–frequency learning framework that identifies series arc faults directly from normalized current waveforms. In Stage I, fast Fourier transform (FFT)-based and wavelet-based learnable front-ends independently learn complementary global spectral and local transient representations. In Stage II, their representation spaces are structured using supervised contrastive learning with view-level and cross-spectrum alignment. In Stage III, the aligned feature extractors are frozen, and only the feature fusion block and final classifier are trained for 10-class classification. Current signals are acquired from a practical smart-farm distribution system and evaluated using a measurement-session-level group-wise split. The framework achieves 99.92% accuracy and 99.93% macro recall while maintaining 1.06 M parameters and a model-only inference latency of 8.70 ms. The results demonstrate that the proposed framework provides robust discrimination across unseen measurement sessions within the evaluated load categories and operating conditions.
- Open Access
- 30 August 2018
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 11 (12) , 1983-1990
Study on electromagnetic energy transducer in ambient vibration
This study documents the design of an electromagnetic energy transducer, which is used to convert ambient vibration into electrical energy. The response of the designed energy transducer is theoretically and experimentally analysed using a simple equivalent circuit model and magnetic field simulator in low‐acceleration environments. For an electromagnetic energy transducer in ambient vibration, an approximate analytical expression is derived for the extracted power across a load. The energy transducer consists of four magnets (NdFeB, N35), two I‐shaped magnetic cores, two U‐shaped cores made of soft ferrite material, and a coil for induced voltage. The two U‐shaped magnetic cores are surrounded by a coil with an approximate 3000 turn. The energy transducer is theoretically modelled using the commercial tool, COMSOL, and is experimentally validated through electrical measurements. The relation between the acceleration of vibration and the maximum average power that can be extracted at the optimal load was also studied. The size of the electromagnetic energy transducer is 43 × 37 × 80 mm 3 . The energy transducer has a maximum average power of 3.24 mW at a frequency of 28 Hz and an acceleration of 0.4 g , and has a maximum average power of 3.83 mW at a frequency of 31 Hz and an acceleration of 0.5 g .
- 30 August 2018
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 11 (12) , 1983-1990
Open AccessStudy on electromagnetic energy transducer in ambient vibration
This study documents the design of an electromagnetic energy transducer, which is used to convert ambient vibration into electrical energy. The response of the designed energy transducer is theoretically and experimentally analysed using a simple equivalent circuit model and magnetic field simulator in low‐acceleration environments. For an electromagnetic energy transducer in ambient vibration, an approximate analytical expression is derived for the extracted power across a load. The energy transducer consists of four magnets (NdFeB, N35), two I‐shaped magnetic cores, two U‐shaped cores made of soft ferrite material, and a coil for induced voltage. The two U‐shaped magnetic cores are surrounded by a coil with an approximate 3000 turn. The energy transducer is theoretically modelled using the commercial tool, COMSOL, and is experimentally validated through electrical measurements. The relation between the acceleration of vibration and the maximum average power that can be extracted at the optimal load was also studied. The size of the electromagnetic energy transducer is 43 × 37 × 80 mm 3 . The energy transducer has a maximum average power of 3.24 mW at a frequency of 28 Hz and an acceleration of 0.4 g , and has a maximum average power of 3.83 mW at a frequency of 31 Hz and an acceleration of 0.5 g .
- 9 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 12 (4) , 3873-3876
Circuit Analysis of Achievable Transmission Efficiency in an Overcoupled Region for Wireless Power Transfer Systems
On nonradiative wireless power transfer (WPT) using a pair of magnetically coupled resonators, we investigate the achievable transmission efficiency for a different set of resonators. Using a simplified equivalent circuit model, we analyze the phenomenon of frequency splitting mathematically in the overcoupled region ($k > k_{\rm {ref}}$). Even though the transmission efficiency tends to gradually decrease as the distance between the two resonators gets closer and closer in the overcoupled region, the transmission efficiency can be improved by tracking one of two separated frequency modes. Based on this observation, we prove mathematically that the achievable transmission efficiency at $k_{\rm {ref}}$ is maintained almost constantly even when $k > k_{\rm {ref}}$ if the identical resonators are used. In order to validate the accuracy of the analysis, we design and fabricate two types of magnetically coupled resonators: one is the set of identical resonators and the other is the set of nonidentical resonators. Through experiments in various environments, we show that the analytical results are in good agreement with the measured ones. Our work can provide an insight into design resonators for short-range WPT systems, in order to ensure better and stable performance.- 9 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 12 (4) , 3873-3876
Circuit Analysis of Achievable Transmission Efficiency in an Overcoupled Region for Wireless Power Transfer Systems
On nonradiative wireless power transfer (WPT) using a pair of magnetically coupled resonators, we investigate the achievable transmission efficiency for a different set of resonators. Using a simplified equivalent circuit model, we analyze the phenomenon of frequency splitting mathematically in the overcoupled region ($k > k_{\rm {ref}}$). Even though the transmission efficiency tends to gradually decrease as the distance between the two resonators gets closer and closer in the overcoupled region, the transmission efficiency can be improved by tracking one of two separated frequency modes. Based on this observation, we prove mathematically that the achievable transmission efficiency at $k_{\rm {ref}}$ is maintained almost constantly even when $k > k_{\rm {ref}}$ if the identical resonators are used. In order to validate the accuracy of the analysis, we design and fabricate two types of magnetically coupled resonators: one is the set of identical resonators and the other is the set of nonidentical resonators. Through experiments in various environments, we show that the analytical results are in good agreement with the measured ones. Our work can provide an insight into design resonators for short-range WPT systems, in order to ensure better and stable performance.- 26 April 2013
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 55 (7) , 1511-1515
Slot‐array antenna for UHF RFID shelf applications
This article presents a linearly polarized slot‐array antenna that consists of a slot series‐fed by a microstrip line for radio frequency identification (RFID) shelf applications in the ultra‐high frequency band in which the end of the microstrip line is shorted to the ground plane by a via‐hole. The radiating element is a U‐shaped slot etched in the ground plane on one side of a substrate and the microstrip line for feeding is etched on the other. The designed 6 × 3 array antenna has the near‐field distribution of electric field intensity from 0.5 to 3.36 V/m for RFID shelf applications. The fractional bandwidth for a reflection coefficient of less than −10 dB is approximately 5.5% at 920 MHz, ranging from 892 to 943 MHz. The antenna installed in the RFID shelf stably reads pharmaceutical products with various package options on the shelf. © 2013 Wiley Periodicals, Inc. Microwave Opt Technol Lett 55:1511–1515, 2013; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.27653
- 26 April 2013
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 55 (7) , 1511-1515
Slot‐array antenna for UHF RFID shelf applications
This article presents a linearly polarized slot‐array antenna that consists of a slot series‐fed by a microstrip line for radio frequency identification (RFID) shelf applications in the ultra‐high frequency band in which the end of the microstrip line is shorted to the ground plane by a via‐hole. The radiating element is a U‐shaped slot etched in the ground plane on one side of a substrate and the microstrip line for feeding is etched on the other. The designed 6 × 3 array antenna has the near‐field distribution of electric field intensity from 0.5 to 3.36 V/m for RFID shelf applications. The fractional bandwidth for a reflection coefficient of less than −10 dB is approximately 5.5% at 920 MHz, ranging from 892 to 943 MHz. The antenna installed in the RFID shelf stably reads pharmaceutical products with various package options on the shelf. © 2013 Wiley Periodicals, Inc. Microwave Opt Technol Lett 55:1511–1515, 2013; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.27653
- Open Access
- 4 April 2012
- Published by Wiley in ETRI Journal
- Vol. 34 (2) , 147-158
Design of Reader Baseband Receiver Structure for Demodulating Backscattered Tag Signal in a Passive RFID Environment
- 4 April 2012
- Published by Wiley in ETRI Journal
- Vol. 34 (2) , 147-158
Open AccessDesign of Reader Baseband Receiver Structure for Demodulating Backscattered Tag Signal in a Passive RFID Environment
- 30 August 2008
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 50 (11) , 2978-2981
A small RFID tag antenna using proximity‐coupling to identify metallic objects
This article presents the design of a small‐ and low‐profile radio frequency identification tag antenna in the UHF band that can be stuck to metallic objects. The designed tag antenna, which uses a ceramic material as an antenna substrate, consists of a radiating patch and microstrip lines for a proximity‐coupled feeding structure. Impedance matching can be simply obtained between the antenna and tag chip without any matching network using the antenna structure. The return‐loss bandwidth for S11 < 10 dB and radiation efficiency are about 9.5 MHz and 40% at 911 MHz, respectively. The read range is approximately from 3 to 3.5 m when the tag antenna is mounted on a metallic surface. © 2008 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 2978–2981, 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.23831
- 30 August 2008
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 50 (11) , 2978-2981
A small RFID tag antenna using proximity‐coupling to identify metallic objects
This article presents the design of a small‐ and low‐profile radio frequency identification tag antenna in the UHF band that can be stuck to metallic objects. The designed tag antenna, which uses a ceramic material as an antenna substrate, consists of a radiating patch and microstrip lines for a proximity‐coupled feeding structure. Impedance matching can be simply obtained between the antenna and tag chip without any matching network using the antenna structure. The return‐loss bandwidth for S11 < 10 dB and radiation efficiency are about 9.5 MHz and 40% at 911 MHz, respectively. The read range is approximately from 3 to 3.5 m when the tag antenna is mounted on a metallic surface. © 2008 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 2978–2981, 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.23831
- Open Access
- 10 April 2006
- Published by Wiley in ETRI Journal
- Vol. 28 (2) , 216-218
An RFID Tag Using a Planar Inverted-F Antenna Capable of Being Stuck to Metallic Objects
- 10 April 2006
- Published by Wiley in ETRI Journal
- Vol. 28 (2) , 216-218
Open AccessAn RFID Tag Using a Planar Inverted-F Antenna Capable of Being Stuck to Metallic Objects