DSD V Sidenkov

D V Sidenkov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


D V Sidenkov has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The effects of the axis ratio on the flow and heat transfer characteristics around a drop-shaped tube

    by R Deeb, D V Sidenkov

    Flow and heat transfer characteristics around single drop-shaped tubes with different axis ratio (L/D) in cross-flow are studied numerically for values of Reynolds number in the range 1.3×103to 20×103. The results are obtained using the commercial software ANSYS Fluent for a two-dimensional (2D) computational domain. The axis ratio of the studied tubes is varied from 1 to 4, whenL/D=1, the tube is circular. The simulation results agree well with the available literature. The distribution of local coefficients of pressure and friction over half of the tube’s surface is plotted and analysed. It found that the drop-shaped tubes delay the separation of the boundary layer from the tube wall. The results confirm that the minimum value of pressure coefficient decreases asL/Ddecreases, and the maximum value of the friction coefficient gradually increases with the growth ofL/D.The result of the numerical simulation indicates the superior overall performance of drop-shaped tube withL/D=4 over the rest of the tubes. Correlations of the average Nusselt number and the friction factor in terms of Reynolds number, calculated by the maximum velocity in the minimum free cross-section, and axis ratios for the studied cases are proposed.


  • Open Access

    Numerical modelling of heat transfer and hydrodynamics for drop-shaped tubes bundle

    by R Deeb, D V Sidenkov

    A numerical study has been conducted to clarify the flow and heat transfer characteristics of a cross-flow heat exchanger with drop-shaped tubes (6-rows of single/double tubes) at zero angle of attack. The study is performed for the Reynolds number Re a = 1.38x103 ∼ 9.36 x103.A mathematical and numerical model in software packageANSYS for numerical evaluation of heat transfer and flow field of a bundle of drop-shaped tubes, with taking into account the strain caused by different pressures inside and outside the tubeshas been developed. Correlations of the average Nusselt number Nu av and a friction factor f in terms of Re D,max and Pr for the studied bundles were presented. The result of the numerical simulation indicates the pressure drop coefficient of the studied drop-shaped tube bundles is about 9.86 ∼ 10.88 times smaller than the circular one.


  • Open Access

    Numerical investigation of heat transfer and friction factor characteristics for staggered double drop-shaped tubes bundle in cross-flow

    by R Deeb, D V Sidenkov

    A numerical study has been conducted to clarify the flow and heat transfer characteristics of a cross-flow heat exchanger with drop-shaped tubes at zero angle of attack. A mathematical and numerical model in software package Ansys for numerical evaluation of heat transfer and flow field of a bundle of drop-shaped tubes, with taking into account the strain caused by different pressures inside and outside the tubes has been developed. The result of the numerical simulation indicates the superior thermal and hydrodynamics performance of the drop-shaped tube bundles over the circular tubes.


  • Open Access

    Numerical simulation of the heat transfer of staggered drop-shaped tubes bundle

    by R Deeb, D V Sidenkov

    Tube bundles can be used as a separation heat exchanger in the “organic” Rankine cycle power plants (ORC), while the hot gas passes over the outer surface, and the working substance ORC flows inside the tubes. A numerical study has been conducted to clarify heat transfer and hydrodynamics of a cross-flow heat exchanger with staggered drop-shaped tubes at different flow angles of attack (θ). A mathematical and numerical model in software package ANSYS has been developed for numerical evaluation of heat transfer and flow field of a bundle of drop-shaped tubes, with taking into account the strain caused by different pressures inside and outside the tubes. The results of numerical simulation of pressure, velocity, temperature distribution in the tube’s bundle had provided the development of equation to determine the average Nusselt number (Nu) in terms of Reynolds number (Re), Prandtl number (Pr) and angle of attack.


  • Open Access

    The evaluation of energy efficiency of convective heat transfer surfaces in tube bundles

    by B A Grigoriev, V A Pronin, V I Salohin, D V Sidenkov

    When evaluating the effectiveness of the heat exchange surfaces in the main considered characteristics such as heat flow (Q, Watt), the power required for pumps (N, Watt), and surface area of heat transfer (F, m2). The most correct comparison provides a comparison "ceteris paribus". Carried out performance comparison "ceteris paribus" in-line and staggered configurations of bundles with a circular pipes can serve as a basis for the development of physical models of flow and heat transfer in tube bundles with tubes of other geometric shapes, considering intertubular stream with attached eddies. The effect of longitudinal and transverse steps of the pipes on the energy efficiency of different configurations would take into account by mean of physical relations between the structure of shell side flow with attached eddies and intensity of transfer processes of heat and momentum. With the aim of energy-efficient placement of tubes, such an approach opens up great opportunities for the synthesis of a plurality of tubular heat exchange surfaces, in particular, the layout of the twisted and in-line-diffuser type with a drop-shaped pipes.


  • Open Access

    Experimental study of the structure of vapor phase during boiling of R134a on heat exchange surfaces of heat pump

    by D A Ustinov, A A Sukhikh, D V Sidenkov, V A Ustinov

    The heat supply by means of heat pumps is considered now as a rational method of local heating which can lead to economy of primary fuel. At use of low-potential heat, for example, the heat of a ground (5 … 18 0 С) or ground waters (8 … 10 0 С) only small depressing of temperature of these sources (on 3 … 5 0 С) is possible that demands application of heat exchangers with intensified heatmass transfer surfaces. In thermal laboratory of TOT department the 200 W experimental installation has been developed for research of process of boiling of freon R134a. The principle of action of the installation consists in realisation of reverse thermodynamic cycle and consecutive natural measurement of characteristics of elements of surfaces of heat exchangers of real installations at boiling points of freon from-10 0 C to +10 0 С and condensing temperatures from 15 0 С to 50 0 С. The evaporator casing has optical windows for control of process of boiling of freon on ribbed on technology of distorting cut tubes. Temperature measurement in characteristic points of a cycle is provided by copperconstantan thermocouples which by means of ADT are connected to the computer that allows treat results of measurements in a real time mode. The structure of a two-phase flow investigated by means of the optical procedure based on laser technique.


  • Open Access

    Combined installation of electric and heat supply for climatic conditions of Iraq

    by Osama Al Kaisi, D V Sidenkov

    Electricity, heating and cooling are the three main components that make up the energy consumption base in residential, commercial and public buildings around the world. Demand for energy and fuel costs are constantly growing. Combined cooling, heating and power generation or trigeneration can be a promising solution to such a problem, providing an efficient, reliable, flexible, competitive and less harmful alternative to existing heat and cold supply systems. In this paper, scheme of the tri-generation plant on non-aqueous working substances is considered as an installation of a locally centralized electro-heat and cold supply of a typical residential house in a hot climate. The scheme of the combined installation of electro-heat (cold) supply consisted of the vapor power plant and heat pump system on lowboiling working substance for local consumers under the climatic conditions of Iraq is presented. The possibility of using different working substances in the thermodynamic cycles of these units, which will provide better efficiency of such tri-generation systems is shown. The calculations of steam turbine cycles and heat pump part on the selected working substances are conducted. It is proposed to use heat exchangers of plate type as the main exchangers in the combined processing. The developed method of thermal-hydraulic calculation of heat exchangers implemented in MathCad, which allows to evaluate the efficiency of plants of this type using the ℇ-NTU method. For the selected working substances of the steam part the optimal temperature of heat supply to the steam generator is determined. The results of thermodynamic and technical-economic analysis of the application of various working substances in the "organic" Rankine cycle of the steam turbine unit and the heat pump system of the heat and cold supply system are presented.

  • Open Access

    Experimental study of thermal conductivity of pyrolysised materials by means of a flat layer

    by V D Vaniushkin, S K Popov, D V Sidenkov

    Recycling of tires is currently a very important task. One of the areas of recycling tires is their low-temperature pyrolysis to produce marketable products-liquid fraction and a solid coke residue. For the development of the pyrolysis installation it is important to know the thermal conductivity of the coke residue at different temperatures of pyrolysis of initial material. As a property of matter, thermal conductivity depends in general on temperature and pressure. For materials with some structure, such as porous materials, the thermal conductivity depends on the characteristics of the structure. The thermal conductivity of the porous coke residue at pyrolysis temperatures of 300 0 C, 400 0 C, 500 0 C and atmospheric pressure was studied experimentally at the laboratory unit of the department of "Theoretical basis of heat engineering" using the method of the flat layer in the temperature range 5...100 0 C. Experimentally proved temperature dependencies of the coefficient of thermal conductivity of the coke residue are built to improve the accuracy of calculations of constructive and regime parameters of the pyrolysis installation.