Lin Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Lin Cao has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Soo Jay Phee
Robotics Research Centre, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
10 shared publicationsPhuoc Thien Phan
School of Mechanical & Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
7 shared publications- Wenjie Lai
Singapore‐HUJ Alliance for Research and Enterprise (SHARE) CREATE Singapore Singapore
7 shared publications Anthony Meng Huat Tiong
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
6 shared publications- Etienne Burdet
Imperial College of Science, Technology and Medicine
6 shared publications - Soo Jay Phee
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
6 shared publications
Latest Publications
- Open Access
- 17 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (42) , eadx3024
Hysteresis-assisted shape morphing for soft continuum robots
Conventional robots require more actuators for greater dexterity, increasing design and control complexity. We introduce a hysteresis-assisted shape-morphing (HasMorph) paradigm for soft continuum robots and integrate with tip-everting soft-growing robots. Unlike conventional approaches that avoid hysteresis, HasMorph intentionally exploits friction-induced shape hysteresis, the difference in robot shape during loading and unloading, to enable numerous reversible shape changes using only two sequentially controlled actuators via an inverted zigzag tendon-sheath mechanism. Integrated with tip growth, the robot achieves complex, reversible morphologies and frictionless follow-the-leader navigation. Mechanics and kinematics models reveal how friction and input sequences govern shape evolution and expand the robot’s configuration space. Experiments validate dexterous morphing and robust navigation in unstructured environments. HasMorph enables direct, fine-grained actuation of hyperredundant soft bodies with minimal actuation, offering a scalable approach to soft robot design. This paradigm opens avenues for minimally invasive surgical tools and adaptive inspection systems in complex, confined spaces.
- 17 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (42) , eadx3024
Open AccessHysteresis-assisted shape morphing for soft continuum robots
Conventional robots require more actuators for greater dexterity, increasing design and control complexity. We introduce a hysteresis-assisted shape-morphing (HasMorph) paradigm for soft continuum robots and integrate with tip-everting soft-growing robots. Unlike conventional approaches that avoid hysteresis, HasMorph intentionally exploits friction-induced shape hysteresis, the difference in robot shape during loading and unloading, to enable numerous reversible shape changes using only two sequentially controlled actuators via an inverted zigzag tendon-sheath mechanism. Integrated with tip growth, the robot achieves complex, reversible morphologies and frictionless follow-the-leader navigation. Mechanics and kinematics models reveal how friction and input sequences govern shape evolution and expand the robot’s configuration space. Experiments validate dexterous morphing and robust navigation in unstructured environments. HasMorph enables direct, fine-grained actuation of hyperredundant soft bodies with minimal actuation, offering a scalable approach to soft robot design. This paradigm opens avenues for minimally invasive surgical tools and adaptive inspection systems in complex, confined spaces.
- Open Access
- 17 July 2025
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 12, 1627116
A pivot joint steering mechanism for tip-everting soft growing robots
Soft growing robots (SGRs) navigate confined environments by everting material from the tip while keeping the rest of the body stationary, enabling frictionless navigation. This opens up huge potential for inspection, search, and rescue tasks. However, controlling the direction of tip growth is still a challenge because of the ever-changing tip of the robot during tip growth. This study presents a compact steering mechanism that integrates a tendon-driven pivot joint with a pressure-tunable internal bladder. By modulating friction between the pivot joint and the inner material, the mechanism switches between two states: decoupled (stationary for bending) and coupled (move forward together with robot’s inner material). This enables the robot to bend locally and then continue growing in the new direction, without using complex full-body actuation or external mechanisms. A robotic platform was developed to implement this mechanism, and its performance was characterized and validated through modeling and experiments. Experimental results confirm that the mechanism achieves reliable tip steering, closely matches kinematics models, and interacts gently with the environment. The proposed design offers a scalable and structurally simple solution for long-range navigation in soft growing robots.
- 17 July 2025
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 12, 1627116
Open AccessA pivot joint steering mechanism for tip-everting soft growing robots
Soft growing robots (SGRs) navigate confined environments by everting material from the tip while keeping the rest of the body stationary, enabling frictionless navigation. This opens up huge potential for inspection, search, and rescue tasks. However, controlling the direction of tip growth is still a challenge because of the ever-changing tip of the robot during tip growth. This study presents a compact steering mechanism that integrates a tendon-driven pivot joint with a pressure-tunable internal bladder. By modulating friction between the pivot joint and the inner material, the mechanism switches between two states: decoupled (stationary for bending) and coupled (move forward together with robot’s inner material). This enables the robot to bend locally and then continue growing in the new direction, without using complex full-body actuation or external mechanisms. A robotic platform was developed to implement this mechanism, and its performance was characterized and validated through modeling and experiments. Experimental results confirm that the mechanism achieves reliable tip steering, closely matches kinematics models, and interacts gently with the environment. The proposed design offers a scalable and structurally simple solution for long-range navigation in soft growing robots.
- Open Access
Design of Soft Robots: A Review of Methods and Future Opportunities for Research
Soft robots present resilient and adaptable systems characterized by deformable bodies inspired by biological systems. In this paper, we comprehensively review existing design methods for soft robots. One unique feature of our review is that we first formulate criteria, which enables us to derive knowledge gaps and suggest future research directions to close these gaps and go further. Another distinctive feature of our review is that we pivot on the general engineering design process for soft robots. As such, we consider three criteria: (1) the availability of design requirements to start with the design of soft robots, (2) the availability of the so-called concept design or architecture design for soft robots, and (3) the systematic process that leads to the final design of soft robots. The review is conducted systematically, especially when searching for and selecting relevant publications in the literature. The main contribution of this review includes (i) identifying knowledge gaps and (ii) suggesting future research directions to close these gaps and go further.
Open AccessDesign of Soft Robots: A Review of Methods and Future Opportunities for Research
Soft robots present resilient and adaptable systems characterized by deformable bodies inspired by biological systems. In this paper, we comprehensively review existing design methods for soft robots. One unique feature of our review is that we first formulate criteria, which enables us to derive knowledge gaps and suggest future research directions to close these gaps and go further. Another distinctive feature of our review is that we pivot on the general engineering design process for soft robots. As such, we consider three criteria: (1) the availability of design requirements to start with the design of soft robots, (2) the availability of the so-called concept design or architecture design for soft robots, and (3) the systematic process that leads to the final design of soft robots. The review is conducted systematically, especially when searching for and selecting relevant publications in the literature. The main contribution of this review includes (i) identifying knowledge gaps and (ii) suggesting future research directions to close these gaps and go further.
- Open Access
- 2 November 2021
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 8
Can the Shape of a Planar Pathway Be Estimated Using Proximal Forces of Inserting a Flexible Shaft?
The shape information of flexible endoscopes or other continuum structures, e.g., intro-vascular catheters, is needed for accurate navigation, motion compensation, and haptic feedback in robotic surgical systems. Existing methods rely on optical fiber sensors, electromagnetic sensors, or expensive medical imaging modalities such as X-ray fluoroscopy, magnetic resonance imaging, and ultrasound to obtain the shape information of these flexible medical devices. Here, we propose to estimate the shape/curvature of a continuum structure by measuring the force required to insert a flexible shaft into the internal channel/pathway of the continuum. We found that there is a consistent correlation between the measured insertion force and curvature of the planar continuum pathway. A testbed was built to insert a flexible shaft into a planar continuum pathway with adjustable shapes. The insertion forces, insertion displacement, and the shapes of the pathway were recorded. A neural network model was developed to model this correlation based on the training data collected on the testbed. The trained model, tested on the testing data, can accurately estimate the curvature magnitudes and the accumulated bending angles of the pathway simply based on the measured insertion force at the proximal end of the shaft. The approach may be used to estimate the curvature magnitudes and accumulated bending angles of flexible endoscopic surgical robots or catheters for accurate motion compensation, haptic force feedback, localization, or navigation. The advantage of this approach is that the employed proximal force can be easily obtained outside the pathway or continuum structure without any embedded sensor in the continuum structure. Future work is needed to further investigate the correlation between insertion forces and the pathway and enhance the capability of the model in estimating more complex shapes, e.g., spatial shapes with multiple bends.
- 2 November 2021
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 8
Open AccessCan the Shape of a Planar Pathway Be Estimated Using Proximal Forces of Inserting a Flexible Shaft?
The shape information of flexible endoscopes or other continuum structures, e.g., intro-vascular catheters, is needed for accurate navigation, motion compensation, and haptic feedback in robotic surgical systems. Existing methods rely on optical fiber sensors, electromagnetic sensors, or expensive medical imaging modalities such as X-ray fluoroscopy, magnetic resonance imaging, and ultrasound to obtain the shape information of these flexible medical devices. Here, we propose to estimate the shape/curvature of a continuum structure by measuring the force required to insert a flexible shaft into the internal channel/pathway of the continuum. We found that there is a consistent correlation between the measured insertion force and curvature of the planar continuum pathway. A testbed was built to insert a flexible shaft into a planar continuum pathway with adjustable shapes. The insertion forces, insertion displacement, and the shapes of the pathway were recorded. A neural network model was developed to model this correlation based on the training data collected on the testbed. The trained model, tested on the testing data, can accurately estimate the curvature magnitudes and the accumulated bending angles of the pathway simply based on the measured insertion force at the proximal end of the shaft. The approach may be used to estimate the curvature magnitudes and accumulated bending angles of flexible endoscopic surgical robots or catheters for accurate motion compensation, haptic force feedback, localization, or navigation. The advantage of this approach is that the employed proximal force can be easily obtained outside the pathway or continuum structure without any embedded sensor in the continuum structure. Future work is needed to further investigate the correlation between insertion forces and the pathway and enhance the capability of the model in estimating more complex shapes, e.g., spatial shapes with multiple bends.
- 26 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (5) , 2556-2567
A Frictional Contact-Pattern-Based Model for Inserting a Flexible Shaft Into Curved Channels
Flexible endoscopy and catheterization typically involve inserting a flexible shaft into a curved channel. Understanding the mechanics involved in the insertion process is crucial for the structural design, actuation, sensing, control, and navigation of these flexible medical tools. However, the ever-changing contacts and friction between the insertion shaft and the pathway make the mechanics complicated. Existing analytical models simplify the problem by neglecting the friction and assuming specific boundary conditions that are valid only in a few specific instances. In the meantime, finite element method models have tradeoffs between computation speed, accuracy, and stability. This article presents an efficient theoretical framework to model the insertion process with friction, promoting fast and accurate computation of the mechanics involved. The inserting shaft is segmented based on the evolving contacts; system equations are formulated with friction-included force equilibrium and boundary conditions. The model is verified through experiments; channels with different shapes/curvatures were considered. The root-mean-square errors between the model and measured insertion forces are less than 0.055 N (average percentage error less than 9.62%). This model will enhance the fundamental understanding of the insertion process's mechanics and benefit the engineering (design, actuation, and control) and medical practices of related medical tools (e.g., endoscopic instruments and catheters).
- 26 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (5) , 2556-2567
A Frictional Contact-Pattern-Based Model for Inserting a Flexible Shaft Into Curved Channels
Flexible endoscopy and catheterization typically involve inserting a flexible shaft into a curved channel. Understanding the mechanics involved in the insertion process is crucial for the structural design, actuation, sensing, control, and navigation of these flexible medical tools. However, the ever-changing contacts and friction between the insertion shaft and the pathway make the mechanics complicated. Existing analytical models simplify the problem by neglecting the friction and assuming specific boundary conditions that are valid only in a few specific instances. In the meantime, finite element method models have tradeoffs between computation speed, accuracy, and stability. This article presents an efficient theoretical framework to model the insertion process with friction, promoting fast and accurate computation of the mechanics involved. The inserting shaft is segmented based on the evolving contacts; system equations are formulated with friction-included force equilibrium and boundary conditions. The model is verified through experiments; channels with different shapes/curvatures were considered. The root-mean-square errors between the model and measured insertion forces are less than 0.055 N (average percentage error less than 9.62%). This model will enhance the fundamental understanding of the insertion process's mechanics and benefit the engineering (design, actuation, and control) and medical practices of related medical tools (e.g., endoscopic instruments and catheters).
- Open Access
- 18 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 91754-91763
Flexible and Deployable Colon Support Structure for Endoluminal Interventions
When performing endoluminal surgery inside the colon using a flexible endoscopic robot, there is a problem of losing visualization and task space due to the collapsing of the surrounding wall. This happens mainly because of the intra-abdominal pressure and peristalsis of the colon. Although insufflation is commonly used for expanding the colon, it does not function when a full-thickness incision is created on the colon wall. To support the collapsing colon and ensure sufficient visualization and task space even with a hole, we developed a deployable colon support structure (CSS) that can be seamlessly adapted to the existing procedures. While the CSS is designed to be small and flexible enough to pass through an endoscopic channel that can be tortuous, it becomes sturdy enough to hold the collapsing/squeezing colon after being deployed. Also, the CSS is collapsible after task completion, for retraction through an endoscopic channel. Through the ex-vivo and in-vivo studies with a swine, we have successfully demonstrated the feasibility of supporting the colon wall during endoluminal interventions with the CSS. We confirmed that the CSS was easily deliverable and deployable and the created space was large enough to perform surgical tasks using robotic arms.
- 18 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 91754-91763
Open AccessFlexible and Deployable Colon Support Structure for Endoluminal Interventions
When performing endoluminal surgery inside the colon using a flexible endoscopic robot, there is a problem of losing visualization and task space due to the collapsing of the surrounding wall. This happens mainly because of the intra-abdominal pressure and peristalsis of the colon. Although insufflation is commonly used for expanding the colon, it does not function when a full-thickness incision is created on the colon wall. To support the collapsing colon and ensure sufficient visualization and task space even with a hole, we developed a deployable colon support structure (CSS) that can be seamlessly adapted to the existing procedures. While the CSS is designed to be small and flexible enough to pass through an endoscopic channel that can be tortuous, it becomes sturdy enough to hold the collapsing/squeezing colon after being deployed. Also, the CSS is collapsible after task completion, for retraction through an endoscopic channel. Through the ex-vivo and in-vivo studies with a swine, we have successfully demonstrated the feasibility of supporting the colon wall during endoluminal interventions with the CSS. We confirmed that the CSS was easily deliverable and deployable and the created space was large enough to perform surgical tasks using robotic arms.
- 8 April 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (9) , 2282-2296
A Three-Limb Teleoperated Robotic System with Foot Control for Flexible Endoscopic Surgery
Flexible endoscopy requires a lot of skill to manipulate both the endoscope and the associated instruments. In most robotic flexible endoscopic systems, the endoscope and instruments are controlled separately by two operators, which may result in communication errors and inefficient operation. Our solution is to enable the surgeon to control both the endoscope and the instruments. Here, we present a novel tele-operation robotic endoscopic system commanded by one operator using the continuous and simultaneous movements of their two hands and one foot. This 13-degree-of-freedom (DoF) system integrates a foot-controlled robotic flexible endoscope and two hand-controlled robotic endoscopic instruments, a robotic grasper and a robotic cauterizing hook. A dedicated foot-interface transfers the natural foot movements to the 4-DoF movements of the endoscope while two other commercial hand interfaces map the movements of the two hands to the two instruments individually. An ex-vivo experiment was carried out by six subjects without surgical experience, where the simultaneous control with foot and hands was compared with a sequential clutch-based hand control. The participants could successfully teleoperate the endoscope and the two instruments to cut the tissues at scattered target areas in a porcine stomach. Foot control yielded 43.7% faster task completion and required less mental effort as compared to the clutch-based hand control scheme, which proves the concept of three-limb tele-operation surgery and the developed flexible endoscopic system.
- 8 April 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (9) , 2282-2296
A Three-Limb Teleoperated Robotic System with Foot Control for Flexible Endoscopic Surgery
Flexible endoscopy requires a lot of skill to manipulate both the endoscope and the associated instruments. In most robotic flexible endoscopic systems, the endoscope and instruments are controlled separately by two operators, which may result in communication errors and inefficient operation. Our solution is to enable the surgeon to control both the endoscope and the instruments. Here, we present a novel tele-operation robotic endoscopic system commanded by one operator using the continuous and simultaneous movements of their two hands and one foot. This 13-degree-of-freedom (DoF) system integrates a foot-controlled robotic flexible endoscope and two hand-controlled robotic endoscopic instruments, a robotic grasper and a robotic cauterizing hook. A dedicated foot-interface transfers the natural foot movements to the 4-DoF movements of the endoscope while two other commercial hand interfaces map the movements of the two hands to the two instruments individually. An ex-vivo experiment was carried out by six subjects without surgical experience, where the simultaneous control with foot and hands was compared with a sequential clutch-based hand control. The participants could successfully teleoperate the endoscope and the two instruments to cut the tissues at scattered target areas in a porcine stomach. Foot control yielded 43.7% faster task completion and required less mental effort as compared to the clutch-based hand control scheme, which proves the concept of three-limb tele-operation surgery and the developed flexible endoscopic system.
- Top Cited Papers
- 6 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (2) , 777-789
A Three-Axial Force Sensor Based on Fiber Bragg Gratings for Surgical Robots
Haptic feedback is absent in flexible endoscopic surgical robots due to the size constraint of installing sensors on the small robotic arms. Besides, inherent hysteresis caused by the nonlinear friction between tendons and sheaths makes it hard to estimate the distal force by modeling. In this work, we addressed this challenge by proposing a new three-axial force sensor. This standalone device can be seamlessly integrated into the endoscopic robotic arm. Three optical fibers with fiber Bragg gratings (FBGs) are embedded in the sensing structure, where one is located at the center hole of the structure (ø 1.4 mm) and the other two are eccentrically placed around the structure at 90° apart from each other. This device can measure the pulling force and lateral forces of an articulated surgical instrument. Mechanics analysis has been studied to reveal the link between FBGs’ wavelength shifts and forces caused by the elongation and the bending with a temperature-compensation feature. The sensor has a lateral force sensitivity of 838.386 pm/N, with a measurement resolution of 1.19 mN. Performance comparison with a commercial force sensor Nano17 was made, with measurement errors from 4.50% to 6.18%. In the ex vivo tests, we teleoperated the sensorized grasper to pull, steer, and lift a piece of pig colon tissue. The tool–tissue interaction forces measured by the force sensor were displayed on the computer screen in real time. In addition to the endoscopic robots, the force sensor can also be integrated with other surgical robots such as laparoscopic robots and catheters.
- 6 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (2) , 777-789
Top Cited PapersA Three-Axial Force Sensor Based on Fiber Bragg Gratings for Surgical Robots
Haptic feedback is absent in flexible endoscopic surgical robots due to the size constraint of installing sensors on the small robotic arms. Besides, inherent hysteresis caused by the nonlinear friction between tendons and sheaths makes it hard to estimate the distal force by modeling. In this work, we addressed this challenge by proposing a new three-axial force sensor. This standalone device can be seamlessly integrated into the endoscopic robotic arm. Three optical fibers with fiber Bragg gratings (FBGs) are embedded in the sensing structure, where one is located at the center hole of the structure (ø 1.4 mm) and the other two are eccentrically placed around the structure at 90° apart from each other. This device can measure the pulling force and lateral forces of an articulated surgical instrument. Mechanics analysis has been studied to reveal the link between FBGs’ wavelength shifts and forces caused by the elongation and the bending with a temperature-compensation feature. The sensor has a lateral force sensitivity of 838.386 pm/N, with a measurement resolution of 1.19 mN. Performance comparison with a commercial force sensor Nano17 was made, with measurement errors from 4.50% to 6.18%. In the ex vivo tests, we teleoperated the sensorized grasper to pull, steer, and lift a piece of pig colon tissue. The tool–tissue interaction forces measured by the force sensor were displayed on the computer screen in real time. In addition to the endoscopic robots, the force sensor can also be integrated with other surgical robots such as laparoscopic robots and catheters.
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 2469-2476
Design and Evaluation of a Foot-Controlled Robotic System for Endoscopic Surgery
In traditional endoscopic surgery, the surgeon manipulating the endoscopic instruments is supported by an assistant controlling the endoscope, where their coordination may be affected by communication errors. To address this issue, we introduce a foot interface controlled robotic endoscopic system, enabling the surgeon to simultaneously operate the endoscope and instruments. The system consists of a foot interface using four degrees of freedom (DoFs) foot gestures and a robotic driving system for a commercial flexible endoscope. The proposed robotic system was validated in teleoperation experiments performed by ten subjects, where foot teleoperation was compared with hand teleoperation and direct control of the endoscope with two hands. The participants could successfully teleoperate the endoscope with foot teleoperation and exhibited 40% faster task completion as with direct control. They found both foot and hand teleoperations comfortable and intuitive. Although hand teleoperation enabled the best performance, only foot teleoperation allows simultaneous control of three instruments.
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 2469-2476
Design and Evaluation of a Foot-Controlled Robotic System for Endoscopic Surgery
In traditional endoscopic surgery, the surgeon manipulating the endoscopic instruments is supported by an assistant controlling the endoscope, where their coordination may be affected by communication errors. To address this issue, we introduce a foot interface controlled robotic endoscopic system, enabling the surgeon to simultaneously operate the endoscope and instruments. The system consists of a foot interface using four degrees of freedom (DoFs) foot gestures and a robotic driving system for a commercial flexible endoscope. The proposed robotic system was validated in teleoperation experiments performed by ten subjects, where foot teleoperation was compared with hand teleoperation and direct control of the endoscope with two hands. The participants could successfully teleoperate the endoscope with foot teleoperation and exhibited 40% faster task completion as with direct control. They found both foot and hand teleoperations comfortable and intuitive. Although hand teleoperation enabled the best performance, only foot teleoperation allows simultaneous control of three instruments.
- 19 November 2020
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (5) , 1391-1401
EndoPil: A Magnetically Actuated Swallowable Capsule for Weight Management: Development and Trials
Intragastric balloons (IGBs), by occupying the stomach space and prolonging satiety, is a promising method to treat obesity and consequently improves its associated comorbidities, e.g. coronary heart disease, diabetes, and cancer. However, existing IGBs are often tethered with tubes for gas or liquid delivery or require endoscopic assistance for device delivery or removal, which are usually uncomfortable, costly, and may cause complications. This paper presents a novel tetherless, magnetically actuated capsule (EndoPil) which can deploy an IGB inside the stomach after being swallowed and being activated by an external magnet. The external magnet attracts a small magnet inside the EndoPil to open a valve, triggering the chemical reaction of citric acid and potassium bicarbonate to produce carbon dioxide gas, which inflates a biocompatible balloon (around 120 mL). A prototype, 13 mm in diameter and 35 mm in length, was developed. Simulations and bench-top tests were conducted to test the force capability of the magnetic actuation mechanism, the required force to activate the valve, and the repeatability of balloon inflation. Experiments on animal and human were successfully conducted to demonstrate the safety and feasibility of inflating a balloon inside the stomach by an external magnet.
- 19 November 2020
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (5) , 1391-1401
EndoPil: A Magnetically Actuated Swallowable Capsule for Weight Management: Development and Trials
Intragastric balloons (IGBs), by occupying the stomach space and prolonging satiety, is a promising method to treat obesity and consequently improves its associated comorbidities, e.g. coronary heart disease, diabetes, and cancer. However, existing IGBs are often tethered with tubes for gas or liquid delivery or require endoscopic assistance for device delivery or removal, which are usually uncomfortable, costly, and may cause complications. This paper presents a novel tetherless, magnetically actuated capsule (EndoPil) which can deploy an IGB inside the stomach after being swallowed and being activated by an external magnet. The external magnet attracts a small magnet inside the EndoPil to open a valve, triggering the chemical reaction of citric acid and potassium bicarbonate to produce carbon dioxide gas, which inflates a biocompatible balloon (around 120 mL). A prototype, 13 mm in diameter and 35 mm in length, was developed. Simulations and bench-top tests were conducted to test the force capability of the magnetic actuation mechanism, the required force to activate the valve, and the repeatability of balloon inflation. Experiments on animal and human were successfully conducted to demonstrate the safety and feasibility of inflating a balloon inside the stomach by an external magnet.