ASArtin A. Shoukas

Artin A. Shoukas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Artin A. Shoukas has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Caitlin S. Thompson-Torgerson

    Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA

    1 shared publication
  • Hunter C. Champion

    Department of Biomedical Engineering, 2Division of Cardiology, Department of Medicine, 3Department of Anesthesiology and Critical Care Medicine, and 4Department of Physiology, Johns Hopkins University School of Medicine, Baltimore, Maryland

    1 shared publication
  • Lakshmi Santhanam

    Department of Biomedical Engineering, 2Division of Cardiology, Department of Medicine, 3Department of Anesthesiology and Critical Care Medicine, and 4Department of Physiology, Johns Hopkins University School of Medicine, Baltimore, Maryland

    1 shared publication
  • Zena Leah Harris

    Dell Medical School at the University of Texas at Austin

    1 shared publication

Latest Publications

  • Cyclohexanone contamination from extracorporeal circuits impairs cardiovascular function

    by Caitlin S. Thompson-Torgerson, Hunter C. Champion, Lakshmi Santhanam, Z. Leah Harris, Artin A. Shoukas

    Extracorporeal circulation provides critical life support in the face of cardiopulmonary or renal failure, but it also introduces a host of unique morbidities characterized by edema formation, cardiac insufficiency, autonomic dysfunction, and altered vasomotor function. We tested the hypothesis that cyclohexanone (CHX), a solvent used in production of extracorporeal circuits and intravenous (IV) bags, leaches into the contained fluids and can replicate these clinical morbidities. Crystalloid fluid samples from circuits and IV bags were analyzed by gas chromatography-mass spectrometry to provide a range of clinical CHX exposure levels, revealing CHX contamination of sampled fluids (9.63–3,694 μg/l). In vivo rat studies were conducted (n = 49) to investigate the effects of a bolus IV infusion of CHX vs. saline alone on cardiovascular function, baroreflex responsiveness, and edema formation. Cardiovascular function was evaluated by cardiac output, heart rate, stroke volume, vascular resistance, arterial pressure, and ventricular contractility. Baroreflex function was assessed by mean femoral arterial pressure responses to bilateral carotid occlusion. Edema formation was assessed by the ratio of wet to dry organ weights for lungs, liver, kidneys, and skin. CHX infusion led to systemic hypotension; pulmonary hypertension; depressed contractility, heart rate, stroke volume, and cardiac output; and elevated vascular resistance (P < 0.05). Mean arterial pressure responsiveness to carotid occlusion was dampened after CHX infusion (from +17.25 ± 1.8 to +5.61 ± 3.2 mmHg; P < 0.05). CHX infusion led to significantly higher wet-to-dry weight ratios vs. saline only (3.8 ± 0.06 vs. 3.5 ± 0.05; P < 0.05). CHX can reproduce clinical cardiovascular, neurological, and edema morbidities associated with extracorporeal circulatory treatment.