B. Cretin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
B. Cretin has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Pascal Vairac
FEMTO-ST Institute, UMR 6174, Université de Franche-Comté, CNRS, ENSMM, UTBM, Besançon 25030, France
5 shared publications P. Vairac
Laboratoire de Physique et Métrologie des Oscillateurs du CNRS, associéà l’Université de Franche-Comté-Besançon, 32 avenue de l’Observatoire, 25044 Besançon Cedex, France
2 shared publicationsA. J. Kulik
1 shared publicationBenoit Charlot
1 shared publication- Celine Filloy
ESPCI / UPRA005 CNRS, Laboratoire d'optique, 10 Rue Vauquelin, Paris, 75005, France
1 shared publication - Danièle Fournier
ESPCI / UPRA005 CNRS, Laboratoire d'optique, 10 Rue Vauquelin, Paris, 75005, France
1 shared publication
Latest Publications
- 30 June 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6791, 679102
Optimized microviscosimeter using optical probing: application to biological membranes
In this article, we report on studies aimed at sensing of the stiffness of membranes, particularly in the case of vesicles. A local approach could be done with AFM techniques but the local information is not pertinent for non homogeneous membranes. To solve this problem, we have developed and checked a specific sensor based on a vibrating sphere. The near-field acoustic wave enables to characterize biological particles which change the apparent viscosity and density of the surrounding fluid. The microsphere is well suited for very small volumes of liquid (typically about one microliter). Globally, the microsensor is based on a silicon cantilever which is glued on a piezoelectric transducer at its clamped end. The sphere is connected to the cantilever with a small glass rod (the core of an optical fiber). When operating, the sphere is immersed inside the investigated liquid and the piezoelectric actuator is excited with a low frequency generator. The vibration of the cantilever is sensed with a heterodyne laser probe. The plot of the response of the sensor (Bode plot) allows computing the properties of the liquid. When biological cells or vesicles are in the fluid, the effect of the biological elements is detectable and can be discriminated. We will present the microsensor and the optical probe which have allowed doing the described measurements. The theoretical study will show the influence of the different parameters and the crucial role of the optical probe to detect the low amplitude vibrations of the cantilever. The experimental results demonstrate the high sensitivity of the sensor to small variation of the composition of the fluid (water), particularly in the case of small vesicles of different kinds. Practically, this is a simulation of cells sensing.
- 30 June 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6791, 679102
Optimized microviscosimeter using optical probing: application to biological membranes
In this article, we report on studies aimed at sensing of the stiffness of membranes, particularly in the case of vesicles. A local approach could be done with AFM techniques but the local information is not pertinent for non homogeneous membranes. To solve this problem, we have developed and checked a specific sensor based on a vibrating sphere. The near-field acoustic wave enables to characterize biological particles which change the apparent viscosity and density of the surrounding fluid. The microsphere is well suited for very small volumes of liquid (typically about one microliter). Globally, the microsensor is based on a silicon cantilever which is glued on a piezoelectric transducer at its clamped end. The sphere is connected to the cantilever with a small glass rod (the core of an optical fiber). When operating, the sphere is immersed inside the investigated liquid and the piezoelectric actuator is excited with a low frequency generator. The vibration of the cantilever is sensed with a heterodyne laser probe. The plot of the response of the sensor (Bode plot) allows computing the properties of the liquid. When biological cells or vesicles are in the fluid, the effect of the biological elements is detectable and can be discriminated. We will present the microsensor and the optical probe which have allowed doing the described measurements. The theoretical study will show the influence of the different parameters and the crucial role of the optical probe to detect the low amplitude vibrations of the cantilever. The experimental results demonstrate the high sensitivity of the sensor to small variation of the composition of the fluid (water), particularly in the case of small vesicles of different kinds. Practically, this is a simulation of cells sensing.
- 27 November 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components and Packaging Technologies
- Vol. 30 (4) , 604-608
Quantitative Thermoreflectance Imaging: Calibration Method and Validation on a Dedicated Integrated Circuit
We have developed a charge-coupled device-based thermoreflectance microscope which can deliver thermal images of working integrated circuits. However, in any thermoreflectance experiment, the coefficient linking reflectance variations to temperature is different for each material. Calibrations are therefore necessary in order to obtain quantitative temperature imaging on the complex surface of an integrated circuit including several materials such as aluminium and polysilicon. We propose here a system using a Peltier element to control the temperature of the whole package in order to obtain calibration coefficients simultaneously on all the materials visible on the surface of the circuit. Under high magnifications, vertical and lateral movements associated to thermal expansion are corrected using respectively a piezo electric displacement and a software image shifting. The thermoreflectance temperature measurements calibrated with this method are compared to the temperatures measured with separately calibrated thermocouples and diodes, and to a finite elements simulation.
- 27 November 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components and Packaging Technologies
- Vol. 30 (4) , 604-608
Quantitative Thermoreflectance Imaging: Calibration Method and Validation on a Dedicated Integrated Circuit
We have developed a charge-coupled device-based thermoreflectance microscope which can deliver thermal images of working integrated circuits. However, in any thermoreflectance experiment, the coefficient linking reflectance variations to temperature is different for each material. Calibrations are therefore necessary in order to obtain quantitative temperature imaging on the complex surface of an integrated circuit including several materials such as aluminium and polysilicon. We propose here a system using a Peltier element to control the temperature of the whole package in order to obtain calibration coefficients simultaneously on all the materials visible on the surface of the circuit. Under high magnifications, vertical and lateral movements associated to thermal expansion are corrected using respectively a piezo electric displacement and a software image shifting. The thermoreflectance temperature measurements calibrated with this method are compared to the temperatures measured with separately calibrated thermocouples and diodes, and to a finite elements simulation.
- 3 November 2003
- Published by AIP Publishing in Applied Physics Letters
- Vol. 83 (18) , 3824-3826
Towards dynamical force microscopy using optical probing of thermomechanical noise
Dynamic force microscopy is often used to investigate local tip–sample interaction in order to obtain the material elastic properties. In this letter, we demonstrate the feasibility of the detection of thermal noise of microcantilever in contact with hard samples. Optical sensing is based on a high sensitivity heterodyne interferometer. The detected power spectral density clearly shows the first flexural vibration mode of the microcantilever. The variation of the resonant frequency of this vibration mode is related to the local elastic properties of the sample.
- 3 November 2003
- Published by AIP Publishing in Applied Physics Letters
- Vol. 83 (18) , 3824-3826
Towards dynamical force microscopy using optical probing of thermomechanical noise
Dynamic force microscopy is often used to investigate local tip–sample interaction in order to obtain the material elastic properties. In this letter, we demonstrate the feasibility of the detection of thermal noise of microcantilever in contact with hard samples. Optical sensing is based on a high sensitivity heterodyne interferometer. The detected power spectral density clearly shows the first flexural vibration mode of the microcantilever. The variation of the resonant frequency of this vibration mode is related to the local elastic properties of the sample.
- 1 May 1999
- Published by Wiley in Surface and Interface Analysis
- Vol. 27 (5-6) , 588-591
Electromechanical resonator in scanning microdeformation microscopy: theory and experiment
- 1 May 1999
- Published by Wiley in Surface and Interface Analysis
- Vol. 27 (5-6) , 588-591
Electromechanical resonator in scanning microdeformation microscopy: theory and experiment
- 1 March 1998
- Published by Springer Nature in Applied Physics A
- Vol. 66 (7) , S235-S238
Measurement of cantilever vibrations with a new heterodyne laser probe: application to scanning microdeformation microscopy
- 1 March 1998
- Published by Springer Nature in Applied Physics A
- Vol. 66 (7) , S235-S238
Measurement of cantilever vibrations with a new heterodyne laser probe: application to scanning microdeformation microscopy
- 1 March 1998
- Published by Springer Nature in Applied Physics A
- Vol. 66 (7) , S227-S230
Frequency shift of a resonating cantilever in a.c. force microscopy: towards a realistic model
- 1 March 1998
- Published by Springer Nature in Applied Physics A
- Vol. 66 (7) , S227-S230
Frequency shift of a resonating cantilever in a.c. force microscopy: towards a realistic model
- 13 October 1997
- Published by AIP Publishing in Applied Physics Letters
- Vol. 71 (15) , 2082-2084
Optical detection for scanning microdeformation microscopy
Scanning microdeformation microscopy is a kind of ac contact force microscopy sensitive to the variations of the local elastic constants of the investigated material. In this letter a new optical interferometer designed for detecting the small displacement of the cantilever is reported. The setup is described and some applications of the laser probe to scanning microdeformation microscopy are demonstrated.
- 13 October 1997
- Published by AIP Publishing in Applied Physics Letters
- Vol. 71 (15) , 2082-2084
Optical detection for scanning microdeformation microscopy
Scanning microdeformation microscopy is a kind of ac contact force microscopy sensitive to the variations of the local elastic constants of the investigated material. In this letter a new optical interferometer designed for detecting the small displacement of the cantilever is reported. The setup is described and some applications of the laser probe to scanning microdeformation microscopy are demonstrated.