Pedro Palma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pedro Palma has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Frangi
ETH Zurich
4 shared publications - René Steiger
Empa, Swiss Federal Laboratories for Materials Science and Technology
4 shared publications Ernst Gehri
Professor emeritus, Dr. h. c., ETH Zürich, Zürich, Switzerland
3 shared publications- Katharina Sroka
ETH Zurich
3 shared publications - Alex Sixie Cao
ETH Zurich
2 shared publications - José Manuel Cabrero
University of Navarra
2 shared publications
Latest Publications
- 18 May 2026
- Published by Springer Nature
- p. 94-99
Guidelines for a Round-Robin Test on Timber Connections Within TC TPT
- 18 May 2026
- Published by Springer Nature
- p. 94-99
Guidelines for a Round-Robin Test on Timber Connections Within TC TPT
- Open Access
- 1 October 2025
- Published by Elsevier in Engineering Structures
- Vol. 345
Dynamic amplification factors in instantaneously loaded structures
- 1 October 2025
- Published by Elsevier in Engineering Structures
- Vol. 345
Open AccessDynamic amplification factors in instantaneously loaded structures
- Open Access
- 24 September 2025
- Published by Springer Nature
- p. 3-15
COST Action HELEN – Holistic Design of Taller Timber Buildings
- 24 September 2025
- Published by Springer Nature
- p. 3-15
Open AccessCOST Action HELEN – Holistic Design of Taller Timber Buildings
- Open Access
- 24 September 2025
- Published by Springer Nature
- p. 403-406
Rate-Dependency and Hysteresis of Timber Connections with a Single Laterally-Loaded Dowel and a Slotted-in Steel Plate
- 24 September 2025
- Published by Springer Nature
- p. 403-406
Open AccessRate-Dependency and Hysteresis of Timber Connections with a Single Laterally-Loaded Dowel and a Slotted-in Steel Plate
- Open Access
- 24 September 2025
- Published by Springer Nature
- p. 225-237
Structural Robustness: Design Framework for Enhanced Robustness
- 24 September 2025
- Published by Springer Nature
- p. 225-237
Open AccessStructural Robustness: Design Framework for Enhanced Robustness
- Open Access
- 24 September 2025
- Published by Springer Nature
- p. 341-349
Disassembly and Reuse in Tall Timber Buildings: Advancing Circular Construction Practices
- 24 September 2025
- Published by Springer Nature
- p. 341-349
Open AccessDisassembly and Reuse in Tall Timber Buildings: Advancing Circular Construction Practices
- Open Access
- 13 August 2025
- Published by Springer Nature in European Journal of Wood and Wood Products
- Vol. 83 (5) , 1-14
Shear strength and stiffness of glued-laminated timber made from European ash (Fraxinus excelsior L.)
The influence of size effects on the shear strength and stiffness of glued-laminated timber (GLT) made from European ash ( Fraxinus excelsior L.) was assessed based on a comprehensive experimental campaign. The experiments were performed on full-scale GLT beams with rectangular cross-sections width × height = b × h = 120 × 480-800 mm 2 , shear lengths L v = 720-1500 mm, and ratios between the shear length L v and the beam height h , i.e. α = L v / h = 1.2-2.5. The influence of the test configuration (3-point bending and asymmetric 4-point bending) was also assessed. The obtained shear strengths of European ash GLT had mean values f v, mean = 10.2 N·mm -2 (coefficient of variation CoV fv = 14%) and 12.2 N·mm -2 ( CoV fv = 15%), for the 3-point and asymmetric 4-point bending test configurations, respectively. The shear strength showed some size dependency, with an exponent 1/ m = 0.2 0.4 for a strength modification factor (600/ h ) 1/ m as a function of the beam height h . The shear modulus showed no size dependency and the obtained mean values were G mean = 1162 N∙mm -2 ( CoV G = 6%) and 1120 N∙mm -2 ( CoV G = 6%), for the 3-point and asymmetric 4-point bending tests, respectively.
- 13 August 2025
- Published by Springer Nature in European Journal of Wood and Wood Products
- Vol. 83 (5) , 1-14
Open AccessShear strength and stiffness of glued-laminated timber made from European ash (Fraxinus excelsior L.)
The influence of size effects on the shear strength and stiffness of glued-laminated timber (GLT) made from European ash ( Fraxinus excelsior L.) was assessed based on a comprehensive experimental campaign. The experiments were performed on full-scale GLT beams with rectangular cross-sections width × height = b × h = 120 × 480-800 mm 2 , shear lengths L v = 720-1500 mm, and ratios between the shear length L v and the beam height h , i.e. α = L v / h = 1.2-2.5. The influence of the test configuration (3-point bending and asymmetric 4-point bending) was also assessed. The obtained shear strengths of European ash GLT had mean values f v, mean = 10.2 N·mm -2 (coefficient of variation CoV fv = 14%) and 12.2 N·mm -2 ( CoV fv = 15%), for the 3-point and asymmetric 4-point bending test configurations, respectively. The shear strength showed some size dependency, with an exponent 1/ m = 0.2 0.4 for a strength modification factor (600/ h ) 1/ m as a function of the beam height h . The shear modulus showed no size dependency and the obtained mean values were G mean = 1162 N∙mm -2 ( CoV G = 6%) and 1120 N∙mm -2 ( CoV G = 6%), for the 3-point and asymmetric 4-point bending tests, respectively.
- 1 February 2024
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 150 (2)
Steel-Reinforced Columns Made of European Beech Glued-Laminated Timber
- 1 February 2024
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 150 (2)
Steel-Reinforced Columns Made of European Beech Glued-Laminated Timber
- Open Access
- 1 July 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (7) , 04022079
Prevention of Disproportionate Collapse for Multistory Mass Timber Buildings: Review of Current Practices and Recent Research
The expanding height of multistory mass timber buildings makes the development of guidance to prevent disproportionate collapse an increasingly important area of engineering design; however, there is no guidance available in building codes or design standards on how to prevent disproportionate collapse of multistory mass timber buildings. In this paper, practical project-specific solutions applied in constructed prominent multistory mass timber buildings to prevent disproportionate collapse are presented. Various approaches have been successfully used for different construction types of multistory mass timber buildings to decrease the potential risk of disproportionate collapse, such as using walls above supports as deep beams and using columns to carry tension forces and hold the floor below in case a supporting column or wall is damaged. Then, recent and ongoing research in the field of prevention of disproportionate collapse of multistory timber buildings is reviewed. Such research is mostly based on numerical simulations of element removal scenarios and pushdown experiments on floor systems and connections and provides valuable insights and guidance to designers on important structural aspects regarding the prevention of disproportionate collapse in multistory mass timber buildings. Finally, the draft provisions for an upcoming standard related to the prevention of disproportionate collapse are reviewed, and the conclusions regarding the state of the art are presented.
- 1 July 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (7) , 04022079
Open AccessPrevention of Disproportionate Collapse for Multistory Mass Timber Buildings: Review of Current Practices and Recent Research
The expanding height of multistory mass timber buildings makes the development of guidance to prevent disproportionate collapse an increasingly important area of engineering design; however, there is no guidance available in building codes or design standards on how to prevent disproportionate collapse of multistory mass timber buildings. In this paper, practical project-specific solutions applied in constructed prominent multistory mass timber buildings to prevent disproportionate collapse are presented. Various approaches have been successfully used for different construction types of multistory mass timber buildings to decrease the potential risk of disproportionate collapse, such as using walls above supports as deep beams and using columns to carry tension forces and hold the floor below in case a supporting column or wall is damaged. Then, recent and ongoing research in the field of prevention of disproportionate collapse of multistory timber buildings is reviewed. Such research is mostly based on numerical simulations of element removal scenarios and pushdown experiments on floor systems and connections and provides valuable insights and guidance to designers on important structural aspects regarding the prevention of disproportionate collapse in multistory mass timber buildings. Finally, the draft provisions for an upcoming standard related to the prevention of disproportionate collapse are reviewed, and the conclusions regarding the state of the art are presented.
- 6 December 2021
- Published by Springer Nature in Wood Science and Technology
- Vol. 56 (1) , 123-146
Predicting the strength of European beech (Fagus sylvatica L.) boards using image-based local fibre direction data
- 6 December 2021
- Published by Springer Nature in Wood Science and Technology
- Vol. 56 (1) , 123-146
Predicting the strength of European beech (Fagus sylvatica L.) boards using image-based local fibre direction data