Hamid Khoshkhoo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hamid Khoshkhoo has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Josep Maria Guerrero
Aalborg University
2 shared publications Ali Parizad
MAPNA Electrical & Control Company
1 shared publicationAref Pouryekta
Clean Technology Center, DNV GL
1 shared publication- Aref Pouryekta
CTC, DNV GL Singapore 118227
1 shared publication Erfan Asadi
Sahand University of Technology,Faculty of Electrical Engineering,Tabriz,Iran
1 shared publicationHadi Abbaspour
Sahand University of Technology,Faculty of Electrical Engineering,Tabriz,Iran
1 shared publication
Latest Publications
- 5 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Determining Energy Storage Systems Capacity for Preventing Cascading Outages During Primary Control: A Dynamic Study
This paper presents a study aimed at determining the optimal capacity of energy storage systems required to prevent frequency instability and cascading outages of power plants during the operation of primary control measures. Unlike previously proposed methods that usually ignore the dynamic response of power systems, accurate load modeling, and the factors affecting the primary control actions, this study considers the dynamic behavior of conventional power plants with high ramp rates that are able to participate in primary frequency control. Furthermore, the optimal capacity needed to prevent frequency instability and cascading outage is determined considering composite load model (combination of static and dynamic loads), which can increase the accuracy of the proposed method. Also, this article considers the effect of the protection system, whose operation may cause the cascading tripping of the power plant and intensify the mismatch of power. The results of dynamic simulations performed in the IEEE 39-Bus test system show the significant role of battery capacity in maintaining frequency stability and preventing power outages.
- 5 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Determining Energy Storage Systems Capacity for Preventing Cascading Outages During Primary Control: A Dynamic Study
This paper presents a study aimed at determining the optimal capacity of energy storage systems required to prevent frequency instability and cascading outages of power plants during the operation of primary control measures. Unlike previously proposed methods that usually ignore the dynamic response of power systems, accurate load modeling, and the factors affecting the primary control actions, this study considers the dynamic behavior of conventional power plants with high ramp rates that are able to participate in primary frequency control. Furthermore, the optimal capacity needed to prevent frequency instability and cascading outage is determined considering composite load model (combination of static and dynamic loads), which can increase the accuracy of the proposed method. Also, this article considers the effect of the protection system, whose operation may cause the cascading tripping of the power plant and intensify the mismatch of power. The results of dynamic simulations performed in the IEEE 39-Bus test system show the significant role of battery capacity in maintaining frequency stability and preventing power outages.
- Open Access
- 27 October 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-23
Survey of Power System Restoration Documents Issued from 2016 to 2021
More than thirty-six partial or whole blackouts, from 2016 to 2021, prove that neither the probability of blackouts can be ignored nor the required plans and the readiness of the utilities for power system restoration can be forgotten. To properly deal with blackouts and minimize the social and economic costs, utilities should prepare a suitable restoration plan in advance to quickly restore the system to the normal state and minimize the restoration time and loss of energy. In this paper, after summarizing major blackouts occurred from 2016 to 2021, the progress in the research reports, industrial documents, and books in the context of power system restoration is reviewed to show and classify the different aspects of power system restoration plans and strategies presented during these years. This review indicates that although there are many published methods and techniques which have tried to give more autonomous solutions, there are still more complexities in power system restoration. However, this paper respects all efforts and attempts and tries to illustrate the achievements, up to now, in power system restoration, as well as research gaps.
- 27 October 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-23
Open AccessSurvey of Power System Restoration Documents Issued from 2016 to 2021
More than thirty-six partial or whole blackouts, from 2016 to 2021, prove that neither the probability of blackouts can be ignored nor the required plans and the readiness of the utilities for power system restoration can be forgotten. To properly deal with blackouts and minimize the social and economic costs, utilities should prepare a suitable restoration plan in advance to quickly restore the system to the normal state and minimize the restoration time and loss of energy. In this paper, after summarizing major blackouts occurred from 2016 to 2021, the progress in the research reports, industrial documents, and books in the context of power system restoration is reviewed to show and classify the different aspects of power system restoration plans and strategies presented during these years. This review indicates that although there are many published methods and techniques which have tried to give more autonomous solutions, there are still more complexities in power system restoration. However, this paper respects all efforts and attempts and tries to illustrate the achievements, up to now, in power system restoration, as well as research gaps.
- 29 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 16 (3) , 4334-4344
A Novel Fast Transient Stability Assessment of Power Systems Using Fault-On Trajectory
In this article, for fast transient stability status (TSS) prediction, a new scheme is proposed, which does not require any postfault data and predicts TSS using data measured until the end of the fault-on period. In this method, phasor measurement units (PMUs) are located at synchronous generators' (SGs) buses to gather time-synchronized data. Then, these measurements are applied to the proposed procedure to calculate the feature set utilizing fault-on and prefault information and predict TSS by a decision tree classifier. Since the feature set does not include any postfault (i.e., after short-circuit clearance) data, the proposed method has the capability of fast prediction of postdisturbance TSS, and hence, it provides more opportunity for system operators and/or special protection systems to implement timely corrective actions to prevent instability. Also, the results of the time-domain analysis carried out in IEEE14-bus, IEEE39-bus, 16-Machine (68-bus), and IEEE118-bus test systems and comparison of them with previous techniques reveal that although the proposed method requires fewer PMUs, it can forecast TSS accurately under N-1 and N-2 conditions. Besides, these results confirm that, considering the measurement error, when the rotor angle of SGs is estimated using the data measured by WAMS, the proposed method accurately predicts TSS.
- 29 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 16 (3) , 4334-4344
A Novel Fast Transient Stability Assessment of Power Systems Using Fault-On Trajectory
In this article, for fast transient stability status (TSS) prediction, a new scheme is proposed, which does not require any postfault data and predicts TSS using data measured until the end of the fault-on period. In this method, phasor measurement units (PMUs) are located at synchronous generators' (SGs) buses to gather time-synchronized data. Then, these measurements are applied to the proposed procedure to calculate the feature set utilizing fault-on and prefault information and predict TSS by a decision tree classifier. Since the feature set does not include any postfault (i.e., after short-circuit clearance) data, the proposed method has the capability of fast prediction of postdisturbance TSS, and hence, it provides more opportunity for system operators and/or special protection systems to implement timely corrective actions to prevent instability. Also, the results of the time-domain analysis carried out in IEEE14-bus, IEEE39-bus, 16-Machine (68-bus), and IEEE118-bus test systems and comparison of them with previous techniques reveal that although the proposed method requires fewer PMUs, it can forecast TSS accurately under N-1 and N-2 conditions. Besides, these results confirm that, considering the measurement error, when the rotor angle of SGs is estimated using the data measured by WAMS, the proposed method accurately predicts TSS.
- 3 November 2020
- Published by Springer Nature
- p. 37-66
Integration of Large-Scale Photovoltaic Power Plants into Power Networks to Maintain System Stability
- 3 November 2020
- Published by Springer Nature
- p. 37-66
Integration of Large-Scale Photovoltaic Power Plants into Power Networks to Maintain System Stability
- 13 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 15 (1) , 923-934
A Remedial Action Scheme to Prevent Mid/Long-Term Voltage Instabilities
The main objective of this article is to propose a special protection system (SPS) to execute efficient remedial actions to prevent mid-term and long-term voltage instabilities. In this method, when the operating point (OP) leaves the normal operation state, the proposed SPS is initiated to execute the required corrective remedial actions to bring the OP back to a normal state and maintain bus voltages above prespecified thresholds. Considering the local nature of Volt/Var control and in order to execute fast remedial actions, in this approach, the required generation rescheduling or load shedding procedures were selected based on the electrical distance concept. This allows for remedial actions with the highest impact on volt/var control. In addition, in generation rescheduling procedures, the proposed method uses the ability of utility-scale photovoltaic resources, which can change their generation quickly. This plays a major role in maintaining stability of power systems. Efficiency of the proposed algorithm was validated through several scenarios performed in IEEE 39-bus, Nordic32, and PST 16 test systems using DIgSILENT PowerFactory software. Results of these dynamic simulations and their comparison with some previously published methods show the effectiveness of this method in timely executing appropriate remedial actions to maintain system stability.
- 13 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 15 (1) , 923-934
A Remedial Action Scheme to Prevent Mid/Long-Term Voltage Instabilities
The main objective of this article is to propose a special protection system (SPS) to execute efficient remedial actions to prevent mid-term and long-term voltage instabilities. In this method, when the operating point (OP) leaves the normal operation state, the proposed SPS is initiated to execute the required corrective remedial actions to bring the OP back to a normal state and maintain bus voltages above prespecified thresholds. Considering the local nature of Volt/Var control and in order to execute fast remedial actions, in this approach, the required generation rescheduling or load shedding procedures were selected based on the electrical distance concept. This allows for remedial actions with the highest impact on volt/var control. In addition, in generation rescheduling procedures, the proposed method uses the ability of utility-scale photovoltaic resources, which can change their generation quickly. This plays a major role in maintaining stability of power systems. Efficiency of the proposed algorithm was validated through several scenarios performed in IEEE 39-bus, Nordic32, and PST 16 test systems using DIgSILENT PowerFactory software. Results of these dynamic simulations and their comparison with some previously published methods show the effectiveness of this method in timely executing appropriate remedial actions to maintain system stability.
- Open Access
- 20 March 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (10) , 1816-1828
Voltage stability assessment algorithm to predict power system loadability margin
In this study, a novel voltage stability assessment algorithm (VSAA) is proposed, which can accurately detect the stability stiffness of power systems. To this purpose, VSAA uses only three measured samples of a bus voltage and the power flowing out of the bus to detect the maximum loadability limit of that bus. Although VSAA has a low computational burden and uses only locally measured data, it can consider the impact of small and/or large disturbances that change the Thevenin equivalent network (i.e. PV curve) seen from the target bus and is able to accurately assess the stability status. To examine the performance of VSAA, it was applied and tested on a 4‐bus, IEEE 39‐bus, Nordic32 and IEEE 33‐bus distribution test systems using DIgSILENT PowerFactory software. The static and dynamic simulation results show the advantages of VSAA over other stability indices proposed in the literature and verify its efficiency and accuracy for online applications.
- 20 March 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (10) , 1816-1828
Open AccessVoltage stability assessment algorithm to predict power system loadability margin
In this study, a novel voltage stability assessment algorithm (VSAA) is proposed, which can accurately detect the stability stiffness of power systems. To this purpose, VSAA uses only three measured samples of a bus voltage and the power flowing out of the bus to detect the maximum loadability limit of that bus. Although VSAA has a low computational burden and uses only locally measured data, it can consider the impact of small and/or large disturbances that change the Thevenin equivalent network (i.e. PV curve) seen from the target bus and is able to accurately assess the stability status. To examine the performance of VSAA, it was applied and tested on a 4‐bus, IEEE 39‐bus, Nordic32 and IEEE 33‐bus distribution test systems using DIgSILENT PowerFactory software. The static and dynamic simulation results show the advantages of VSAA over other stability indices proposed in the literature and verify its efficiency and accuracy for online applications.
- Open Access
- 26 December 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (4) , e2806
A comprehensive assessment to propose an improved line stability index
So far, several line stability indices have been introduced and used for evaluating voltage stability status of power systems. The objective of this paper is to propose a comprehensive assessment of these indices and also to propose a modified line stability index to accurately assess the stability status of networks in different situations. To this purpose, the performance of several line indices at different conditions is analyzed. Also, to categorize system states to normal, alert, and emergency, proper thresholds are proposed for these indices. It will be shown that although line indices are able to properly assess the stability of a two‐bus system, they cannot detect the stability status in real networks. Therefore, a modified index has been proposed, which can accurately assess the stability status of power systems. The static and dynamic simulation results performed in the Institute of Electrical and Electronics Engineer (IEEE) 39‐ and 118‐bus test systems verify the performance of the proposed index.
- 26 December 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (4) , e2806
Open AccessA comprehensive assessment to propose an improved line stability index
So far, several line stability indices have been introduced and used for evaluating voltage stability status of power systems. The objective of this paper is to propose a comprehensive assessment of these indices and also to propose a modified line stability index to accurately assess the stability status of networks in different situations. To this purpose, the performance of several line indices at different conditions is analyzed. Also, to categorize system states to normal, alert, and emergency, proper thresholds are proposed for these indices. It will be shown that although line indices are able to properly assess the stability of a two‐bus system, they cannot detect the stability status in real networks. Therefore, a modified index has been proposed, which can accurately assess the stability status of power systems. The static and dynamic simulation results performed in the Institute of Electrical and Electronics Engineer (IEEE) 39‐ and 118‐bus test systems verify the performance of the proposed index.
- 30 December 2017
- Published by Springer Nature
- p. 125-151
Dynamic Stability Improvement of Islanded Power Plant by Smart Power Management System: Implementation of PMS Logic
- 30 December 2017
- Published by Springer Nature
- p. 125-151
Dynamic Stability Improvement of Islanded Power Plant by Smart Power Management System: Implementation of PMS Logic