Wei Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wei Pan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Rui Xue
Chinese Academy of Sciences
2 shared publications - Shaoqi Yang
Chinese Academy of Sciences
2 shared publications - Xiujuan Xie
State Key Laboratory of Cryogenic Science and Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications - Dongsheng Ni
Institute of Modern Physics of Chinese Academy of Sciences, Lanzhou, China
1 shared publication - Gang Zhou
Chinese Academy of Sciences
1 shared publication J H Wu
State Key Laboratory of Technologies in Space Cryogenic Propellants, TIPC/CAS, Beijing, 100190, China
1 shared publication
Latest Publications
- 6 October 2023
- Published by Springer Nature
- p. 33-40
Design and Preliminary Test of a Helium Cryogenic Refrigerator for the High Energy FRagment Separator of HIAF
- 6 October 2023
- Published by Springer Nature
- p. 33-40
Design and Preliminary Test of a Helium Cryogenic Refrigerator for the High Energy FRagment Separator of HIAF
- 6 October 2023
- Published by Springer Nature
- p. 85-91
Investigation on Dry Vacuum Pumps Suitable for Superfluid Helium Cryogenic Refrigeration
- 6 October 2023
- Published by Springer Nature
- p. 85-91
Investigation on Dry Vacuum Pumps Suitable for Superfluid Helium Cryogenic Refrigeration
- Open Access
- 29 December 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 278 (1) , 012087
The control system of a 2kW@20K helium refrigerator
The automatic control of a helium refrigerator includes three aspects, that is, one-button start and stop control, safety protection control, and cooling capacity control. The 2kW@20K helium refrigerator's control system uses the SIEMENS PLC S7-300 and its related programming and configuration software Step7 and the industrial monitoring software WinCC, to realize the dynamic control of its process, the real-time monitoring of its data, the safety interlock control, and the optimal control of its cooling capacity. At first, this paper describes the control architecture of the whole system in detail, including communication configuration and equipment introduction; and then introduces the sequence control strategy of the dynamic processes, including the start and stop control mode of the machine and the safety interlock control strategy of the machine; finally tells the precise control strategy of the machine's cooling capacity. Eventually, the whole system achieves the target of one-button starting and stopping, automatic fault protection and stable running to the target cooling capacity, and help finished the cold helium pressurization test of aerospace products.
- 29 December 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 278 (1) , 012087
Open AccessThe control system of a 2kW@20K helium refrigerator
The automatic control of a helium refrigerator includes three aspects, that is, one-button start and stop control, safety protection control, and cooling capacity control. The 2kW@20K helium refrigerator's control system uses the SIEMENS PLC S7-300 and its related programming and configuration software Step7 and the industrial monitoring software WinCC, to realize the dynamic control of its process, the real-time monitoring of its data, the safety interlock control, and the optimal control of its cooling capacity. At first, this paper describes the control architecture of the whole system in detail, including communication configuration and equipment introduction; and then introduces the sequence control strategy of the dynamic processes, including the start and stop control mode of the machine and the safety interlock control strategy of the machine; finally tells the precise control strategy of the machine's cooling capacity. Eventually, the whole system achieves the target of one-button starting and stopping, automatic fault protection and stable running to the target cooling capacity, and help finished the cold helium pressurization test of aerospace products.