Brian A. Burnett
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brian A. Burnett has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Mark A. Williams
WMG, University of Warwick, Coventry, UK
5 shared publications - Danielle G. Norman
University of Warwick, Coventry, UK.
3 shared publications - Jason M. Warnett
University of Warwick
3 shared publications - Mark Payne
West Midlands Police, Police Headquarters, Lloyd House, Colmore Circus, Birmingham B4 6NQ, England, United Kingdom
3 shared publications - Waltraud Baier
WMG, International Manufacturing Centre, University of Warwick Coventry, CV4 7AL, UK
3 shared publications - Derrick G. Watson
Department of Psychology, University of Warwick, Coventry CV4 7AL, UK
2 shared publications
Latest Publications
- Open Access
- 12 November 2019
- Published by Springer Nature in International journal of legal medicine
- Vol. 134 (4) , 1441-1450
Using micro-computed tomography to examine the larynx in cases of suspected strangulation—a comparison of case findings and control images
The examination of strangulation is one of the most challenging causes of death diagnoses encountered in forensic pathology. The injuries are often subtle and difficult to detect, especially in cases that lack superficial marks. Fractures of the laryngeal skeleton are commonly regarded as evidence of strangulation but these can be too subtle to be detected during autopsy. Micro-CT is a novel imaging technique that achieves a spatial resolution 1 μm or less which lends itself to the examination of small and delicate structures such as the larynx. However, there is little information to date regarding the appearance of the larynx at this scale, thus complicating the interpretation of the micro-CT images. This study therefore uses micro-CT to examine ten larynges from strangulation deaths and to compare them to nineteen samples from donor individuals in order to distinguish between naturally occurring features and actual trauma. It was found that there are several features which mimic damage in the donor group. Using associated case information, initial trends and patterns of different strangulation methods were established.
- 12 November 2019
- Published by Springer Nature in International journal of legal medicine
- Vol. 134 (4) , 1441-1450
Open AccessUsing micro-computed tomography to examine the larynx in cases of suspected strangulation—a comparison of case findings and control images
The examination of strangulation is one of the most challenging causes of death diagnoses encountered in forensic pathology. The injuries are often subtle and difficult to detect, especially in cases that lack superficial marks. Fractures of the laryngeal skeleton are commonly regarded as evidence of strangulation but these can be too subtle to be detected during autopsy. Micro-CT is a novel imaging technique that achieves a spatial resolution 1 μm or less which lends itself to the examination of small and delicate structures such as the larynx. However, there is little information to date regarding the appearance of the larynx at this scale, thus complicating the interpretation of the micro-CT images. This study therefore uses micro-CT to examine ten larynges from strangulation deaths and to compare them to nineteen samples from donor individuals in order to distinguish between naturally occurring features and actual trauma. It was found that there are several features which mimic damage in the donor group. Using associated case information, initial trends and patterns of different strangulation methods were established.
- Open Access
- 1 December 2018
- Published by Elsevier in Forensic Science International
- Vol. 293, 91-100
Micro-CT for saw mark analysis on human bone
- 1 December 2018
- Published by Elsevier in Forensic Science International
- Vol. 293, 91-100
Open AccessMicro-CT for saw mark analysis on human bone
- Open Access
- 1 February 2018
- Published by Elsevier in Forensic Science International
- Vol. 283, 156-172
The cutting edge — Micro-CT for quantitative toolmark analysis of sharp force trauma to bone
- 1 February 2018
- Published by Elsevier in Forensic Science International
- Vol. 283, 156-172
Open AccessThe cutting edge — Micro-CT for quantitative toolmark analysis of sharp force trauma to bone
- Open Access
- 1 January 2018
- Published by Elsevier in Forensic Science International
- Vol. 282, 93
Corrigendum to “Novel application of three-dimensional technologies in a case of dismemberment” [Forensic Sci. Int. 270C (2017) 139–145]
- 1 January 2018
- Published by Elsevier in Forensic Science International
- Vol. 282, 93
Open AccessCorrigendum to “Novel application of three-dimensional technologies in a case of dismemberment” [Forensic Sci. Int. 270C (2017) 139–145]
- Open Access
- 1 January 2017
- Published by Elsevier in Forensic Science International
- Vol. 270, 139-145
Novel application of three-dimensional technologies in a case of dismemberment
- 1 January 2017
- Published by Elsevier in Forensic Science International
- Vol. 270, 139-145
Open AccessNovel application of three-dimensional technologies in a case of dismemberment