Qi Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qi Guo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Mengjun Liao
EPRI of China Southern Power Grid
2 shared publications- Changgang Li
Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, Shandong University, Jinan 250061, China
1 shared publication - Changyu Liu
School of Civil and Hydraulic Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, China
1 shared publication - Hengxu Zhang
School of Electrical Engineering, Shandong University, Jinan 250061, China
1 shared publication - Qiurong Yan
College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
1 shared publication - Tian Tian
School of Hydropower and Information Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
1 shared publication
Latest Publications
- 27 December 2025
- Published by Springer Nature
- p. 1357-1380
Dynamic/Transient Interactions with AC Network Components and Other Converters
- 27 December 2025
- Published by Springer Nature
- p. 1357-1380
Dynamic/Transient Interactions with AC Network Components and Other Converters
- 27 April 2024
- Published by Springer Nature
- p. 1-25
Dynamic/Transient Interactions with AC Network Components and Other Converters
- 27 April 2024
- Published by Springer Nature
- p. 1-25
Dynamic/Transient Interactions with AC Network Components and Other Converters
- Open Access
Evaluation of DFIGs’ Primary Frequency Regulation Capability for Power Systems with High Penetration of Wind Power
Accompanying the continuous increase in wind power penetration, the power system inertia is reduced, and the system frequency regulation performance deteriorates. Wind turbine generators are required to participate in primary frequency regulation (PFR) to support system frequency. Here, the PFR capability of the widely-used doubly-fed induction generator (DFIG) is evaluated to estimate the participation of the DFIG in system frequency control. The frequency regulation model of the DFIG is established and briefly discussed. The equivalent PFR droop coefficient is then deduced from the model using a small signal increment method to evaluate the DFIG’s PFR capability. Key factors affecting the equivalent droop coefficient are studied, and the droop control is optimized to keep the equivalent droop coefficient in the desired range. The proposed method is verified utilizing a provincial power grid model of China.
Open AccessEvaluation of DFIGs’ Primary Frequency Regulation Capability for Power Systems with High Penetration of Wind Power
Accompanying the continuous increase in wind power penetration, the power system inertia is reduced, and the system frequency regulation performance deteriorates. Wind turbine generators are required to participate in primary frequency regulation (PFR) to support system frequency. Here, the PFR capability of the widely-used doubly-fed induction generator (DFIG) is evaluated to estimate the participation of the DFIG in system frequency control. The frequency regulation model of the DFIG is established and briefly discussed. The equivalent PFR droop coefficient is then deduced from the model using a small signal increment method to evaluate the DFIG’s PFR capability. Key factors affecting the equivalent droop coefficient are studied, and the droop control is optimized to keep the equivalent droop coefficient in the desired range. The proposed method is verified utilizing a provincial power grid model of China.
- Open Access
An Improved Ant Lion Optimization Algorithm and Its Application in Hydraulic Turbine Governing System Parameter Identification
In this paper, an improved ant lion optimization (IALO) algorithm for parameter identification of hydraulic turbine governing system (HTGS) is proposed. In the proposed algorithm, the search space is explored by the ant lion optimization first, and then the domain is searched by the particle swarm optimization (PSO) in each iteration cycle. A chaotic mutation operation namely Logistics map is introduced for the elite to break out of the local optimum. In mutation operation, a serial-parallel combined method is developed to increase the diversity of mutant population. When the proposed IALO algorithm is applied in the parameter identification of HTGS, the comparative simulation results show that the proposed IALO algorithm has the highest accuracy among different optimization algorithms, and the proposed IALO algorithm has a good convergence characteristic and high stability.
Open AccessAn Improved Ant Lion Optimization Algorithm and Its Application in Hydraulic Turbine Governing System Parameter Identification
In this paper, an improved ant lion optimization (IALO) algorithm for parameter identification of hydraulic turbine governing system (HTGS) is proposed. In the proposed algorithm, the search space is explored by the ant lion optimization first, and then the domain is searched by the particle swarm optimization (PSO) in each iteration cycle. A chaotic mutation operation namely Logistics map is introduced for the elite to break out of the local optimum. In mutation operation, a serial-parallel combined method is developed to increase the diversity of mutant population. When the proposed IALO algorithm is applied in the parameter identification of HTGS, the comparative simulation results show that the proposed IALO algorithm has the highest accuracy among different optimization algorithms, and the proposed IALO algorithm has a good convergence characteristic and high stability.