Gang Zong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gang Zong has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Bin Peng
School of Environment and Architecture, University of Shanghai for Science and Technology, Shanghai 200093, China
1 shared publication - Dongdong Wang
University of Shanghai for Science and Technology
1 shared publication - Fengyu Zhang
Department of Disaster Mitigation for Structures, Tongji University, Shanghai 200092, China
1 shared publication Guang-Zhen Ren
Tongji University College of Civil Engineering
1 shared publication- Jie Xiao
School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou 510006, China
1 shared publication - Jinhai Zhao
College of Mechanics and Engineering Science, Hohai University, Nanjing 211100, China
1 shared publication
Latest Publications
- Open Access
An Excitation Modification Method for Predicting Subway-Induced Vibrations of Unopened Lines
Accurate prediction of subway-induced environmental vibrations for unopened lines remains a significant challenge due to the difficulty in determining appropriate excitation inputs. To address this issue, this study proposes an excitation modification method based on field measurements and numerical simulations. First, field measurements were conducted on a subway line in Shanghai to analyze vibration propagation characteristics and validate a two-dimensional finite element model (FEM). Subsequently, based on the validated model, frequency-band excitation modification formulas were derived. Distinct from existing empirical approaches that often rely on simple statistical scaling, the proposed method utilizes parametric numerical analyses to determine frequency-dependent correction coefficients for four key parameters: tunnel burial depth, tunnel diameter, soil properties, and train speed. The reliability of the proposed method was verified through theoretical analysis and an engineering application. The results demonstrate that the proposed method improves prediction accuracy for tunnels in similar soft soil regions, reducing the prediction error from 10.1% to 5.2% in the engineering case study. Furthermore, parametric sensitivity analysis reveals that ground vibration levels generally decrease with increases in burial depth, tunnel diameter, and soil stiffness, while exhibiting an increase with train speed. This study improves the reliability of vibration prediction in the absence of direct measurements and provides a practical tool for early-stage design and vibration mitigation for unopened lines.
Open AccessAn Excitation Modification Method for Predicting Subway-Induced Vibrations of Unopened Lines
Accurate prediction of subway-induced environmental vibrations for unopened lines remains a significant challenge due to the difficulty in determining appropriate excitation inputs. To address this issue, this study proposes an excitation modification method based on field measurements and numerical simulations. First, field measurements were conducted on a subway line in Shanghai to analyze vibration propagation characteristics and validate a two-dimensional finite element model (FEM). Subsequently, based on the validated model, frequency-band excitation modification formulas were derived. Distinct from existing empirical approaches that often rely on simple statistical scaling, the proposed method utilizes parametric numerical analyses to determine frequency-dependent correction coefficients for four key parameters: tunnel burial depth, tunnel diameter, soil properties, and train speed. The reliability of the proposed method was verified through theoretical analysis and an engineering application. The results demonstrate that the proposed method improves prediction accuracy for tunnels in similar soft soil regions, reducing the prediction error from 10.1% to 5.2% in the engineering case study. Furthermore, parametric sensitivity analysis reveals that ground vibration levels generally decrease with increases in burial depth, tunnel diameter, and soil stiffness, while exhibiting an increase with train speed. This study improves the reliability of vibration prediction in the absence of direct measurements and provides a practical tool for early-stage design and vibration mitigation for unopened lines.
- Open Access
Crack Propagation Analysis of Steels with Initial Defects by New Peridynamics
Steel structure specimens exhibit high strength and ductility and are often subjected to complex loading conditions and pre-existing cracks in critical engineering applications. In this study, peridynamics (PD) theory—known for its unique advantages in modeling structural damage and failure—is employed to establish specimens with bilateral cracks and double central cracks at varying longitudinal spacings. To address the complexity of elastic–plastic behavior, the D-M model is applied to transform the nonlinear problem into an equivalent linear elastic one. This approach is integrated with PD theory and the crack tip opening displacement (COD) concept of fracture mechanics to derive a novel linear fracture criterion, termed the PD-COD. Furthermore, numerical models based on PD and the PD-COD criterion are developed for central cross double-crack specimens, enabling analysis of crack propagation under loading. The results validate the effectiveness of the PD-COD damage criterion and elucidate the underlying mechanisms of crack propagation in centrally intersecting double-crack configurations. This work contributes to a deeper understanding of the damage evolution in defective steel structures under load and provides theoretical guidance for engineering design.
Open AccessCrack Propagation Analysis of Steels with Initial Defects by New Peridynamics
Steel structure specimens exhibit high strength and ductility and are often subjected to complex loading conditions and pre-existing cracks in critical engineering applications. In this study, peridynamics (PD) theory—known for its unique advantages in modeling structural damage and failure—is employed to establish specimens with bilateral cracks and double central cracks at varying longitudinal spacings. To address the complexity of elastic–plastic behavior, the D-M model is applied to transform the nonlinear problem into an equivalent linear elastic one. This approach is integrated with PD theory and the crack tip opening displacement (COD) concept of fracture mechanics to derive a novel linear fracture criterion, termed the PD-COD. Furthermore, numerical models based on PD and the PD-COD criterion are developed for central cross double-crack specimens, enabling analysis of crack propagation under loading. The results validate the effectiveness of the PD-COD damage criterion and elucidate the underlying mechanisms of crack propagation in centrally intersecting double-crack configurations. This work contributes to a deeper understanding of the damage evolution in defective steel structures under load and provides theoretical guidance for engineering design.
- Open Access
- 20 November 2023
- Published by Springer Nature in Research Square
Analysis of Acceleration Signal of Field-Structure Seismological Networks and Assessment of Far-field Earthquake Action in Shanghai
The monitoring acceleration signal of field and structure is the first-hand data for assessment of earthquake action. Two field-structure seismological networks were set on different campuses of Tongji University and were put on the top floor of two tall buildings along with the field nearby. A 21-story steel-concrete composite structure and a 14-story reinforced concrete structure of two seismological networks are the tallest buildings on the two campuses. Twenty-three far-field earthquake records were obtained from October 2020 to January 2023. In this paper, the monitoring acceleration signals of the field and structure were analyzed. The actual measured amplification coefficient of the monitored structure was obtained according to the ratio of the peak value of structure signal and the ground signal, and compared with the actual response spectrum of the structure. Based on the statistical analysis of effective peak ground acceleration, the future peak level of far-field ground acceleration was obtained. The response spectrum of 5% damping ratio was obtained and found to be larger than the design spectrum curve. Corresponding to intersection point of two major regions of the spectrum curve, the characteristic period was longer than the value of 0.9s in the design code. And the spectrum curve spikes at a period of about 2.5s in the decline region. All these demonstrates double peak before and after the characteristic period in the response amplification spectrum curve, which was the basic features of the far-field earthquake action of two seismological networks. The spike of the spectrum curve in the long-period region means the amplification of long-period components in the earthquake signal. It is caused by the deep saturated covering layer in Shanghai and should be paid more attention to, especially for highly flexible structures.
- 20 November 2023
- Published by Springer Nature in Research Square
Open AccessAnalysis of Acceleration Signal of Field-Structure Seismological Networks and Assessment of Far-field Earthquake Action in Shanghai
The monitoring acceleration signal of field and structure is the first-hand data for assessment of earthquake action. Two field-structure seismological networks were set on different campuses of Tongji University and were put on the top floor of two tall buildings along with the field nearby. A 21-story steel-concrete composite structure and a 14-story reinforced concrete structure of two seismological networks are the tallest buildings on the two campuses. Twenty-three far-field earthquake records were obtained from October 2020 to January 2023. In this paper, the monitoring acceleration signals of the field and structure were analyzed. The actual measured amplification coefficient of the monitored structure was obtained according to the ratio of the peak value of structure signal and the ground signal, and compared with the actual response spectrum of the structure. Based on the statistical analysis of effective peak ground acceleration, the future peak level of far-field ground acceleration was obtained. The response spectrum of 5% damping ratio was obtained and found to be larger than the design spectrum curve. Corresponding to intersection point of two major regions of the spectrum curve, the characteristic period was longer than the value of 0.9s in the design code. And the spectrum curve spikes at a period of about 2.5s in the decline region. All these demonstrates double peak before and after the characteristic period in the response amplification spectrum curve, which was the basic features of the far-field earthquake action of two seismological networks. The spike of the spectrum curve in the long-period region means the amplification of long-period components in the earthquake signal. It is caused by the deep saturated covering layer in Shanghai and should be paid more attention to, especially for highly flexible structures.
- Open Access
- 18 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (20) , 11411
Automatic Identification of the Working State of High-Rise Building Machine Based on Machine Learning
High-rise building machines (HBMs) play a crucial role in the construction of super-tall buildings, with their working states directly impacting safety, quality, and progress. Given their extensive floor coverage and complex internal structures, monitoring priorities should shift according to specific workflows. However, existing research has primarily focused on monitoring key HBM components during specific stages, neglecting the automated recognition of HBM workflows, which hinders adaptive monitoring strategies. This study investigates the critical states of HBM construction across various structural layers and proposes a method rooted in vibration signal analysis to determine the HBM’s working state. The method involves collecting vibration signals with a triaxial accelerometer, extracting five distinct vibration signal features, classifying these signals using a k-Nearest Neighbors (kNN) classifier, and finally, outputting the results through a classification rule that aligns with the actual workflow of the HBM. The method was implemented in super-high-rise buildings exceeding 350 m, achieving a measured accuracy of 97.4% in HBM working state recognition. This demonstrates its proficiency in accurately determining the construction state and facilitating timely feedback. Utilizing vibration signal analysis can enhance the efficiency and safety, with potential applications in monitoring large-scale formwork equipment construction processes. This approach provides a versatile solution for a wide range of climbing equipment used in the construction of super-tall buildings and towering structures.
- 18 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (20) , 11411
Open AccessAutomatic Identification of the Working State of High-Rise Building Machine Based on Machine Learning
High-rise building machines (HBMs) play a crucial role in the construction of super-tall buildings, with their working states directly impacting safety, quality, and progress. Given their extensive floor coverage and complex internal structures, monitoring priorities should shift according to specific workflows. However, existing research has primarily focused on monitoring key HBM components during specific stages, neglecting the automated recognition of HBM workflows, which hinders adaptive monitoring strategies. This study investigates the critical states of HBM construction across various structural layers and proposes a method rooted in vibration signal analysis to determine the HBM’s working state. The method involves collecting vibration signals with a triaxial accelerometer, extracting five distinct vibration signal features, classifying these signals using a k-Nearest Neighbors (kNN) classifier, and finally, outputting the results through a classification rule that aligns with the actual workflow of the HBM. The method was implemented in super-high-rise buildings exceeding 350 m, achieving a measured accuracy of 97.4% in HBM working state recognition. This demonstrates its proficiency in accurately determining the construction state and facilitating timely feedback. Utilizing vibration signal analysis can enhance the efficiency and safety, with potential applications in monitoring large-scale formwork equipment construction processes. This approach provides a versatile solution for a wide range of climbing equipment used in the construction of super-tall buildings and towering structures.
- 4 April 2017
- Published by Springer Nature in International Journal of Civil Engineering
- Vol. 16 (7) , 757-768
Investigation of the Influences of Asymmetric Damages on Seismic Assessments for Existing Masonry Structures
- 4 April 2017
- Published by Springer Nature in International Journal of Civil Engineering
- Vol. 16 (7) , 757-768
Investigation of the Influences of Asymmetric Damages on Seismic Assessments for Existing Masonry Structures