Mariusz Kamiński
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mariusz Kamiński has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Piotr Budzynski
Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin, Poland
18 shared publications - Mirosław Szala
Faculty of Mechanical Engineering, Lublin University of Technology, Lublin, Poland
8 shared publications - Marek Wiertel
Department of Physics, Institute of Physics, Maria Curie-Sklodowska University, Pl. Marii Curie-Skłodowskiej 1, 20-031 Lublin, Poland
7 shared publications - Zbigniew Surowiec
Department of Physics, Institute of Physics, Maria Curie-Sklodowska University, Pl. Marii Curie-Skłodowskiej 1, 20-031 Lublin, Poland
6 shared publications - Marcin Turek
Institute of Physics Maria Curie‐Skłodowska University Lublin Poland
3 shared publications A Droździel
Institute of Physics, M.Curie-Sklodowska University, M.Curie-Sklodowska sq. 1, 20-031 Lublin, Poland
2 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Walter de Gruyter GmbH in Advances in Materials Science
- Vol. 26 (3) , 83-98
Assessment of the Archard Hardness–Wear Relationship in Swift Xe-Ion-Irradiated Nickel-Based Superalloys
The study evaluates whether irradiation-induced changes in tribological wear of nickel-based superalloys can be explained by corresponding hardness changes using a normalized Archard approach. Previously obtained microhardness and wear data for Inconel 718 and Nimonic 90 irradiated with 160 MeV Xe 24+ ions at fluences of 1.0×10; 14 , 2.5 × 10 14 , and 5.0×10 14 ions/cm 2 were reprocessed. Relative hardness R H , relative wear-track area R A , and the relative Archard coefficient k r were calculated for hardness measured at 1, 5, and 10 gf. For Inconel 718, R H reached 1.87, R A decreased to 0.40, and k r ranged from 0.61 to 1.86. For Nimonic 90, R H decreased to 0.53, R A increased to 30.69, and k r ranged from 4.04 to 31.19. The dependence of k r on indentation load further indicates that a single hardness value may be insufficient for Archard-type interpretation of irradiation-modified surface layers. The results show that wear changes cannot be explained by hardness scaling alone and must be considered together with depth-dependent mechanical response and changes in tribological contact conditions.
- 1 September 2026
- Published by Walter de Gruyter GmbH in Advances in Materials Science
- Vol. 26 (3) , 83-98
Open AccessAssessment of the Archard Hardness–Wear Relationship in Swift Xe-Ion-Irradiated Nickel-Based Superalloys
The study evaluates whether irradiation-induced changes in tribological wear of nickel-based superalloys can be explained by corresponding hardness changes using a normalized Archard approach. Previously obtained microhardness and wear data for Inconel 718 and Nimonic 90 irradiated with 160 MeV Xe 24+ ions at fluences of 1.0×10; 14 , 2.5 × 10 14 , and 5.0×10 14 ions/cm 2 were reprocessed. Relative hardness R H , relative wear-track area R A , and the relative Archard coefficient k r were calculated for hardness measured at 1, 5, and 10 gf. For Inconel 718, R H reached 1.87, R A decreased to 0.40, and k r ranged from 0.61 to 1.86. For Nimonic 90, R H decreased to 0.53, R A increased to 30.69, and k r ranged from 4.04 to 31.19. The dependence of k r on indentation load further indicates that a single hardness value may be insufficient for Archard-type interpretation of irradiation-modified surface layers. The results show that wear changes cannot be explained by hardness scaling alone and must be considered together with depth-dependent mechanical response and changes in tribological contact conditions.
- Open Access
Changes in the Tribological and Mechanical Properties of Nimonic 90 Superalloy After Irradiation with Swift Xenon Ions
The article presents the results of research on the effect of 160 MeV xenon ions irradiation on the mechanical and tribological properties of the Nimonic 90 superalloy. The alloy samples were irradiated with xenon ion fluences ranging from 1 × 1014 to 5 × 1014 Xe24+/cm2 at a temperature of 60 °C. The investigations revealed significant changes in the crystal structure of the material, including the formation of new phases and partial amorphisation of the surface layer, particularly pronounced at the highest irradiation fluence. Measurements of microhardness, coefficient of friction, and wear revealed a deterioration in the mechanical and tribological properties of the samples irradiated with fluences of 1.0 and 2.5 × 1014 Xe24+ ions/cm2, attributed to the formation of radiation-induced defects. Increased friction and wear were observed at depths greater than the predicted range of xenon ions, indicating the occurrence of a long-range effect. After irradiation with a 5.0 × 1014 Xe24+ ions/cm2 fluence, a radiation annealing effect was observed, leading to a partial reduction in the earlier damage and resulting in improved microhardness and reduced wear. To our knowledge, this is the first observation of a radiation annealing effect under these specific irradiation and test conditions. The findings suggest limitations in the application of the Nimonic 90 superalloy in environments exposed to intense ionizing radiation, such as nuclear reactors.
Open AccessChanges in the Tribological and Mechanical Properties of Nimonic 90 Superalloy After Irradiation with Swift Xenon Ions
The article presents the results of research on the effect of 160 MeV xenon ions irradiation on the mechanical and tribological properties of the Nimonic 90 superalloy. The alloy samples were irradiated with xenon ion fluences ranging from 1 × 1014 to 5 × 1014 Xe24+/cm2 at a temperature of 60 °C. The investigations revealed significant changes in the crystal structure of the material, including the formation of new phases and partial amorphisation of the surface layer, particularly pronounced at the highest irradiation fluence. Measurements of microhardness, coefficient of friction, and wear revealed a deterioration in the mechanical and tribological properties of the samples irradiated with fluences of 1.0 and 2.5 × 1014 Xe24+ ions/cm2, attributed to the formation of radiation-induced defects. Increased friction and wear were observed at depths greater than the predicted range of xenon ions, indicating the occurrence of a long-range effect. After irradiation with a 5.0 × 1014 Xe24+ ions/cm2 fluence, a radiation annealing effect was observed, leading to a partial reduction in the earlier damage and resulting in improved microhardness and reduced wear. To our knowledge, this is the first observation of a radiation annealing effect under these specific irradiation and test conditions. The findings suggest limitations in the application of the Nimonic 90 superalloy in environments exposed to intense ionizing radiation, such as nuclear reactors.
- Open Access
- 11 December 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (24) , 1986
Tunable TiZrMoC Coatings: A Comprehensive Study of Microstructure, Mechanical Properties, and Wear Resistance
TiZrMoC coatings were deposited on Si(100) substrates using a DC dual magnetron sputtering. The composition was controlled by adjusting the sputtering parameters of the TiZrMo and graphite targets. The influence of graphite target current on the resulting coating properties was explored. TEM analysis revealed a single-phase structure with Ti/Mo/Zr substitutional elements, columnar grains, and a strong [111] texture. Nanotwins and stacking faults were prevalent within the nanocrystals. EDX, SIMS, XRD, and XPS analyses confirmed the elemental composition and nanostructure. Computational modeling was employed to investigate the mixing behavior of the quaternary solid solutions depending on the valency electron concentration. The films exhibited exceptional mechanical properties, including a maximum hardness of 35 GPa and a wear rate of 2.11 × 10−7 mm3N−1m−1, attributed to the presence of an amorphous carbon layer and optimized deposition parameters. These findings demonstrate the potential of TiZrMoC coatings for advanced applications requiring exceptional wear resistance and durability.
- 11 December 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (24) , 1986
Open AccessTunable TiZrMoC Coatings: A Comprehensive Study of Microstructure, Mechanical Properties, and Wear Resistance
TiZrMoC coatings were deposited on Si(100) substrates using a DC dual magnetron sputtering. The composition was controlled by adjusting the sputtering parameters of the TiZrMo and graphite targets. The influence of graphite target current on the resulting coating properties was explored. TEM analysis revealed a single-phase structure with Ti/Mo/Zr substitutional elements, columnar grains, and a strong [111] texture. Nanotwins and stacking faults were prevalent within the nanocrystals. EDX, SIMS, XRD, and XPS analyses confirmed the elemental composition and nanostructure. Computational modeling was employed to investigate the mixing behavior of the quaternary solid solutions depending on the valency electron concentration. The films exhibited exceptional mechanical properties, including a maximum hardness of 35 GPa and a wear rate of 2.11 × 10−7 mm3N−1m−1, attributed to the presence of an amorphous carbon layer and optimized deposition parameters. These findings demonstrate the potential of TiZrMoC coatings for advanced applications requiring exceptional wear resistance and durability.
- Open Access
Effect of Xenon Ion Irradiation on the Properties of Austenitic Steel AISI 316
This study investigated changes in the crystal lattice, tribological properties and friction mechanism of AISI 316 steel irradiated with swift 160 MeV xenon ions. The irradiation process caused the increased roughness of the steel surface and the swelling of the material. The thickness of the irradiated layer increased by about 13 nm. Following irradiation with the fluences 2.5 × 1014 and 3.2 × 1014 (Xe24+/cm2), martensite formed in the surface layer. Fluctuating changes were also observed with respect to the coefficient of friction and the degree of wear of the AISI 316 steel samples. Irradiation also increased the microhardness of the steel.
Open AccessEffect of Xenon Ion Irradiation on the Properties of Austenitic Steel AISI 316
This study investigated changes in the crystal lattice, tribological properties and friction mechanism of AISI 316 steel irradiated with swift 160 MeV xenon ions. The irradiation process caused the increased roughness of the steel surface and the swelling of the material. The thickness of the irradiated layer increased by about 13 nm. Following irradiation with the fluences 2.5 × 1014 and 3.2 × 1014 (Xe24+/cm2), martensite formed in the surface layer. Fluctuating changes were also observed with respect to the coefficient of friction and the degree of wear of the AISI 316 steel samples. Irradiation also increased the microhardness of the steel.
- Open Access
- 20 June 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (12) , 1061
Microstructural, Electrical, and Tribomechanical Properties of Mo-W-C Nanocomposite Films
This study investigates the phase composition, microstructure, and their influence on the properties of Mo-W-C nanocomposite films deposited by dual-source magnetron sputtering. The synthesised films consist of metal carbide nanograins embedded in an amorphous carbon matrix. It has been found that nanograins are composed of the hexagonal β-(Mo2 + W2)C phase at a low carbon source power. An increase in the power results in the change in the structure of the carbide nanoparticles from a single-phase to a mixture of the β-(Mo2 + W2)C and NaCl-type α-(Mo + W)C(0.65≤k≤1) solid-solution phases. The analysis of electrical properties demonstrates that the nanograin structure of the films favours the occurrence of hopping conductivity. The double-phase structure leads to a twofold increase in the relaxation time compared to the single-phase one. Films with both types of nanograin structures exhibit tunnelling conductance without the need for thermal activation. The average distance between the potential wells produced by the carbide nanograins in nanocomposite films is approximately 3.4 ± 0.2 nm. A study of tribomechanical properties showed that Mo-W-C films composed of a mixture of the β-(Mo2 + W2)C and α-(Mo + W)C(0.65≤k≤1) phases have the highest hardness (19–22 GPa) and the lowest friction coefficient (0.15–0.24) and wear volume (0.00302–0.00381 mm2). Such a combination of electrical and tribomechanical properties demonstrates the suitability of Mo-W-C nanocomposite films for various micromechanical devices and power electronics.
- 20 June 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (12) , 1061
Open AccessMicrostructural, Electrical, and Tribomechanical Properties of Mo-W-C Nanocomposite Films
This study investigates the phase composition, microstructure, and their influence on the properties of Mo-W-C nanocomposite films deposited by dual-source magnetron sputtering. The synthesised films consist of metal carbide nanograins embedded in an amorphous carbon matrix. It has been found that nanograins are composed of the hexagonal β-(Mo2 + W2)C phase at a low carbon source power. An increase in the power results in the change in the structure of the carbide nanoparticles from a single-phase to a mixture of the β-(Mo2 + W2)C and NaCl-type α-(Mo + W)C(0.65≤k≤1) solid-solution phases. The analysis of electrical properties demonstrates that the nanograin structure of the films favours the occurrence of hopping conductivity. The double-phase structure leads to a twofold increase in the relaxation time compared to the single-phase one. Films with both types of nanograin structures exhibit tunnelling conductance without the need for thermal activation. The average distance between the potential wells produced by the carbide nanograins in nanocomposite films is approximately 3.4 ± 0.2 nm. A study of tribomechanical properties showed that Mo-W-C films composed of a mixture of the β-(Mo2 + W2)C and α-(Mo + W)C(0.65≤k≤1) phases have the highest hardness (19–22 GPa) and the lowest friction coefficient (0.15–0.24) and wear volume (0.00302–0.00381 mm2). Such a combination of electrical and tribomechanical properties demonstrates the suitability of Mo-W-C nanocomposite films for various micromechanical devices and power electronics.
- Open Access
Effect of 160 MeV Xenon Ion Irradiation on the Tribological Properties and Crystal Structure of 100Cr6 Bearing Steel
This is the first study ever to show the impact of high-energy 160 MeV xenon ion irradiation on the properties of 100Cr6 bearing steel. The projected range (Rp) of xenon ions is 8.2 µm. Fluence-dependent variations in the coefficient of friction and wear of the 100Cr6 steel material have been observed. These changes correlate with shifts in the crystal lattice constant and variations in the oxygen, carbon, and iron content in the wear track. Fluence-dependent changes in these parameters have been observed for the first time. Irradiation reduces stresses in the crystal lattice, leading to crystallite size increase. The modifications in the properties of 100Cr6 steel result from radiation-induced defects caused by electronic ion stopping. The degree of these modifications depends on the applied irradiation fluence. Furthermore, the use of a higher irradiation fluence value appears to mitigate the effects produced by a lower fluence.
Open AccessEffect of 160 MeV Xenon Ion Irradiation on the Tribological Properties and Crystal Structure of 100Cr6 Bearing Steel
This is the first study ever to show the impact of high-energy 160 MeV xenon ion irradiation on the properties of 100Cr6 bearing steel. The projected range (Rp) of xenon ions is 8.2 µm. Fluence-dependent variations in the coefficient of friction and wear of the 100Cr6 steel material have been observed. These changes correlate with shifts in the crystal lattice constant and variations in the oxygen, carbon, and iron content in the wear track. Fluence-dependent changes in these parameters have been observed for the first time. Irradiation reduces stresses in the crystal lattice, leading to crystallite size increase. The modifications in the properties of 100Cr6 steel result from radiation-induced defects caused by electronic ion stopping. The degree of these modifications depends on the applied irradiation fluence. Furthermore, the use of a higher irradiation fluence value appears to mitigate the effects produced by a lower fluence.
- Open Access
- 1 January 2023
- Published by TANGER Ltd.
- Vol. 2023, 461-466
Effect of high-energy Xe ion implantation on tribological properties of chromium under wet conditions
- 1 January 2023
- Published by TANGER Ltd.
- Vol. 2023, 461-466
Open AccessEffect of high-energy Xe ion implantation on tribological properties of chromium under wet conditions
- Open Access
Effect of Nitrogen Ion Implantation on the Cavitation Erosion Resistance and Cobalt-Based Solid Solution Phase Transformations of HIPed Stellite 6
From the wide range of engineering materials traditional Stellite 6 (cobalt alloy) exhibits excellent resistance to cavitation erosion (CE). Nonetheless, the influence of ion implantation of cobalt alloys on the CE behaviour has not been completely clarified by the literature. Thus, this work investigates the effect of nitrogen ion implantation (NII) of HIPed Stellite 6 on the improvement of resistance to CE. Finally, the cobalt-rich matrix phase transformations due to both NII and cavitation load were studied. The CE resistance of stellites ion-implanted by 120 keV N+ ions two fluences: 5 × 1016 cm−2 and 1 × 1017 cm−2 were comparatively analysed with the unimplanted stellite and AISI 304 stainless steel. CE tests were conducted according to ASTM G32 with stationary specimen method. Erosion rate curves and mean depth of erosion confirm that the nitrogen-implanted HIPed Stellite 6 two times exceeds the resistance to CE than unimplanted stellite, and has almost ten times higher CE reference than stainless steel. The X-ray diffraction (XRD) confirms that NII of HIPed Stellite 6 favours transformation of the ε(hcp) to γ(fcc) structure. Unimplanted stellite ε-rich matrix is less prone to plastic deformation than γ and consequently, increase of γ phase effectively holds carbides in cobalt matrix and prevents Cr7C3 debonding. This phenomenon elongates three times the CE incubation stage, slows erosion rate and mitigates the material loss. Metastable γ structure formed by ion implantation consumes the cavitation load for work-hardening and γ → ε martensitic transformation. In further CE stages, phases transform as for unimplanted alloy namely, the cavitation-inducted recovery process, removal of strain, dislocations resulting in increase of γ phase. The CE mechanism was investigated using a surface profilometer, atomic force microscopy, SEM-EDS and XRD. HIPed Stellite 6 wear behaviour relies on the plastic deformation of cobalt matrix, starting at Cr7C3/matrix interfaces. Once the Cr7C3 particles lose from the matrix restrain, they debond from matrix and are removed from the material. Carbides detachment creates cavitation pits which initiate cracks propagation through cobalt matrix, that leads to loss of matrix phase and as a result the CE proceeds with a detachment of massive chunk of materials.
Open AccessEffect of Nitrogen Ion Implantation on the Cavitation Erosion Resistance and Cobalt-Based Solid Solution Phase Transformations of HIPed Stellite 6
From the wide range of engineering materials traditional Stellite 6 (cobalt alloy) exhibits excellent resistance to cavitation erosion (CE). Nonetheless, the influence of ion implantation of cobalt alloys on the CE behaviour has not been completely clarified by the literature. Thus, this work investigates the effect of nitrogen ion implantation (NII) of HIPed Stellite 6 on the improvement of resistance to CE. Finally, the cobalt-rich matrix phase transformations due to both NII and cavitation load were studied. The CE resistance of stellites ion-implanted by 120 keV N+ ions two fluences: 5 × 1016 cm−2 and 1 × 1017 cm−2 were comparatively analysed with the unimplanted stellite and AISI 304 stainless steel. CE tests were conducted according to ASTM G32 with stationary specimen method. Erosion rate curves and mean depth of erosion confirm that the nitrogen-implanted HIPed Stellite 6 two times exceeds the resistance to CE than unimplanted stellite, and has almost ten times higher CE reference than stainless steel. The X-ray diffraction (XRD) confirms that NII of HIPed Stellite 6 favours transformation of the ε(hcp) to γ(fcc) structure. Unimplanted stellite ε-rich matrix is less prone to plastic deformation than γ and consequently, increase of γ phase effectively holds carbides in cobalt matrix and prevents Cr7C3 debonding. This phenomenon elongates three times the CE incubation stage, slows erosion rate and mitigates the material loss. Metastable γ structure formed by ion implantation consumes the cavitation load for work-hardening and γ → ε martensitic transformation. In further CE stages, phases transform as for unimplanted alloy namely, the cavitation-inducted recovery process, removal of strain, dislocations resulting in increase of γ phase. The CE mechanism was investigated using a surface profilometer, atomic force microscopy, SEM-EDS and XRD. HIPed Stellite 6 wear behaviour relies on the plastic deformation of cobalt matrix, starting at Cr7C3/matrix interfaces. Once the Cr7C3 particles lose from the matrix restrain, they debond from matrix and are removed from the material. Carbides detachment creates cavitation pits which initiate cracks propagation through cobalt matrix, that leads to loss of matrix phase and as a result the CE proceeds with a detachment of massive chunk of materials.