Gergely Csány
Gergely Csány has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Miklós Gyöngy
Faculty of Information Technology and Bionics Pázmány Péter Catholic University Budapest Hungary
6 shared publications - Klára Szalai
Department of Dermatology, Venereology and Dermatooncology, Semmelweis University, Mária u. 41, 1085 Budapest, Hungary
4 shared publications - Domonkos Csabai
Dermus Ltd., Sopron út 64, 1116 Budapest, Hungary
3 shared publications - Péter Marosán-Vilimszky
Faculty of Information Technology and Bionics, Pázmány Péter Catholic University, Práter u. 50/a, 1083 Budapest, Hungary
3 shared publications - András Horváth
Dipartimento di Informatica, Università di Torino, Torino, Italy
2 shared publications - Kende Lőrincz
Department of Dermatology, Venereology and Dermatooncology Semmelweis University Budapest Hungary
2 shared publications
Latest Publications
- Open Access
- 15 January 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (1) , 204
Preliminary Clinical Experience with a Novel Optical–Ultrasound Imaging Device on Various Skin Lesions
A compact handheld skin ultrasound imaging device has been developed that uses co-registered optical and ultrasound imaging to provide diagnostic information about the full skin depth. The aim of the current work is to present the preliminary clinical results of this device. Using additional photographic, dermoscopic and ultrasonic images as reference, the images from the device were assessed in terms of the detectability of the main skin layer boundaries and characteristic image features. Combined optical-ultrasonic recordings of various types of skin lesions (melanoma, basal cell carcinoma, seborrheic keratosis, dermatofibroma, naevus, dermatitis and psoriasis) were taken with the device (N = 53) and compared with images captured with a reference portable skin ultrasound imager. The investigator and two additional independent experts performed the evaluation. The detectability of skin structures was over 90% for the epidermis, the dermis and the lesions. The morphological and echogenicity information observed for the different skin lesions were found consistent with those of the reference ultrasound device and relevant ultrasound images in the literature. The presented device was able to obtain simultaneous in-vivo optical and ultrasound images of various skin lesions. This has the potential for further investigations, including the preoperative planning of skin cancer treatment.
- 15 January 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (1) , 204
Open AccessPreliminary Clinical Experience with a Novel Optical–Ultrasound Imaging Device on Various Skin Lesions
A compact handheld skin ultrasound imaging device has been developed that uses co-registered optical and ultrasound imaging to provide diagnostic information about the full skin depth. The aim of the current work is to present the preliminary clinical results of this device. Using additional photographic, dermoscopic and ultrasonic images as reference, the images from the device were assessed in terms of the detectability of the main skin layer boundaries and characteristic image features. Combined optical-ultrasonic recordings of various types of skin lesions (melanoma, basal cell carcinoma, seborrheic keratosis, dermatofibroma, naevus, dermatitis and psoriasis) were taken with the device (N = 53) and compared with images captured with a reference portable skin ultrasound imager. The investigator and two additional independent experts performed the evaluation. The detectability of skin structures was over 90% for the epidermis, the dermis and the lesions. The morphological and echogenicity information observed for the different skin lesions were found consistent with those of the reference ultrasound device and relevant ultrasound images in the literature. The presented device was able to obtain simultaneous in-vivo optical and ultrasound images of various skin lesions. This has the potential for further investigations, including the preoperative planning of skin cancer treatment.
- Open Access
- 3 July 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (7) , 1207
Automated Skin Lesion Classification on Ultrasound Images
The growing incidence of skin cancer makes computer-aided diagnosis tools for this group of diseases increasingly important. The use of ultrasound has the potential to complement information from optical dermoscopy. The current work presents a fully automatic classification framework utilizing fully-automated (FA) segmentation and compares it with classification using two semi-automated (SA) segmentation methods. Ultrasound recordings were taken from a total of 310 lesions (70 melanoma, 130 basal cell carcinoma and 110 benign nevi). A support vector machine (SVM) model was trained on 62 features, with ten-fold cross-validation. Six classification tasks were considered, namely all the possible permutations of one class versus one or two remaining classes. The receiver operating characteristic (ROC) area under the curve (AUC) as well as the accuracy (ACC) were measured. The best classification was obtained for the classification of nevi from cancerous lesions (melanoma, basal cell carcinoma), with AUCs of over 90% and ACCs of over 85% obtained with all segmentation methods. Previous works have either not implemented FA ultrasound-based skin cancer classification (making diagnosis more lengthy and operator-dependent), or are unclear in their classification results. Furthermore, the current work is the first to assess the effect of implementing FA instead of SA classification, with FA classification never degrading performance (in terms of AUC or ACC) by more than 5%.
- 3 July 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (7) , 1207
Open AccessAutomated Skin Lesion Classification on Ultrasound Images
The growing incidence of skin cancer makes computer-aided diagnosis tools for this group of diseases increasingly important. The use of ultrasound has the potential to complement information from optical dermoscopy. The current work presents a fully automatic classification framework utilizing fully-automated (FA) segmentation and compares it with classification using two semi-automated (SA) segmentation methods. Ultrasound recordings were taken from a total of 310 lesions (70 melanoma, 130 basal cell carcinoma and 110 benign nevi). A support vector machine (SVM) model was trained on 62 features, with ten-fold cross-validation. Six classification tasks were considered, namely all the possible permutations of one class versus one or two remaining classes. The receiver operating characteristic (ROC) area under the curve (AUC) as well as the accuracy (ACC) were measured. The best classification was obtained for the classification of nevi from cancerous lesions (melanoma, basal cell carcinoma), with AUCs of over 90% and ACCs of over 85% obtained with all segmentation methods. Previous works have either not implemented FA ultrasound-based skin cancer classification (making diagnosis more lengthy and operator-dependent), or are unclear in their classification results. Furthermore, the current work is the first to assess the effect of implementing FA instead of SA classification, with FA classification never degrading performance (in terms of AUC or ACC) by more than 5%.
- Open Access
First clinical experience with a novel optical-ultrasound imaging device on various skin pathologies
Objectives A compact handheld skin ultrasound imaging device has been developed that uses co-registered optical and ultrasound imaging to provide diagnostic information about the full skin depth and lesions encountered therein. The aim of the current work is to present the first clinical results of the device. Using additional photographic, dermoscopic and ultrasonic images as reference, the images from the device are assessed in terms of the detectability of the skin layer boundaries (between the epidermis, dermis, and subcutis), and in terms of image features produced by common skin lesions. Methods Combined optical-ultrasonic recordings of various types of common skin lesions (melanoma, basal cell carcinoma, keratosis, dermatofibroma, naevus, dermatitis, psoriasis) were taken with the device (N = 53) and compared with images from a reference portable skin ultrasound imager. The investigator and two additional independent experts evaluated and compared the images in terms of skin structure detectability and skin lesion features. Results Skin structure detectability was unanimously over 90 % for epidermis, dermis and lesion. Morphological and echogenicity information observed for melanoma, basal cell carcinoma, keratoses, dermatofibroma, naevi, atopic dermatitis, psoriasis were found consistent with those of the reference ultrasound device and relevant ultrasound images in the literature. Conclusions The presented device is able to obtain simultaneous in-vivo optical and ultrasound images of common skin lesions. This has the potential to provide relevant information in a number of settings to be investigated in the future, including preoperative planning of skin cancer treatment.
Open AccessFirst clinical experience with a novel optical-ultrasound imaging device on various skin pathologies
Objectives A compact handheld skin ultrasound imaging device has been developed that uses co-registered optical and ultrasound imaging to provide diagnostic information about the full skin depth and lesions encountered therein. The aim of the current work is to present the first clinical results of the device. Using additional photographic, dermoscopic and ultrasonic images as reference, the images from the device are assessed in terms of the detectability of the skin layer boundaries (between the epidermis, dermis, and subcutis), and in terms of image features produced by common skin lesions. Methods Combined optical-ultrasonic recordings of various types of common skin lesions (melanoma, basal cell carcinoma, keratosis, dermatofibroma, naevus, dermatitis, psoriasis) were taken with the device (N = 53) and compared with images from a reference portable skin ultrasound imager. The investigator and two additional independent experts evaluated and compared the images in terms of skin structure detectability and skin lesion features. Results Skin structure detectability was unanimously over 90 % for epidermis, dermis and lesion. Morphological and echogenicity information observed for melanoma, basal cell carcinoma, keratoses, dermatofibroma, naevi, atopic dermatitis, psoriasis were found consistent with those of the reference ultrasound device and relevant ultrasound images in the literature. Conclusions The presented device is able to obtain simultaneous in-vivo optical and ultrasound images of common skin lesions. This has the potential to provide relevant information in a number of settings to be investigated in the future, including preoperative planning of skin cancer treatment.
- Open Access
- 1 February 2021
- Published by Elsevier in Ultrasonics
- Vol. 110, 106268
Automated seeding for ultrasound skin lesion segmentation
- 1 February 2021
- Published by Elsevier in Ultrasonics
- Vol. 110, 106268
Open AccessAutomated seeding for ultrasound skin lesion segmentation
- Open Access
Estimation of Acoustic Power Output from Electrical Impedance Measurements
A method is proposed for estimating the acoustic power output of ultrasound transducers using a two-port model with electrical impedance measurements made in three different propagation media. When evaluated for two high-intensity focused ultrasound transducers at centre frequencies between 0.50 and 3.19 MHz, the resulting power estimates exceeded acoustic estimates by 4.5–21.8%. The method was shown to be valid for drive levels producing up to 20 MPa in water and should therefore be appropriate for many HIFU (high-intensity focused ultrasound) applications, with the primary advantage of employing relatively low-cost, non-specialist materials and instrumentation.
Open AccessEstimation of Acoustic Power Output from Electrical Impedance Measurements
A method is proposed for estimating the acoustic power output of ultrasound transducers using a two-port model with electrical impedance measurements made in three different propagation media. When evaluated for two high-intensity focused ultrasound transducers at centre frequencies between 0.50 and 3.19 MHz, the resulting power estimates exceeded acoustic estimates by 4.5–21.8%. The method was shown to be valid for drive levels producing up to 20 MPa in water and should therefore be appropriate for many HIFU (high-intensity focused ultrasound) applications, with the primary advantage of employing relatively low-cost, non-specialist materials and instrumentation.
- 16 October 2018
- Published by Elsevier in Ultrasonics
- Vol. 93, 26-36
A real-time data-based scan conversion method for single element ultrasound transducers
- 16 October 2018
- Published by Elsevier in Ultrasonics
- Vol. 93, 26-36
A real-time data-based scan conversion method for single element ultrasound transducers
- 1 January 2017
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 32 (1) , 055002
Simultaneous enhancement of B-mode axial and lateral resolution using axial deconvolution
Enhancement of image resolution in ultrasound images is key to help clinicians end early indicators of pathological lesions. Image resolution enhancement relies on deconvolving the point spread function (PSF) of the imaging system out of the raw ultrasound image prior to envelope detection and other postprocessing steps. Unfortunately, in most cases the PSF is spatially variant, complicating its estimation and subsequent use in deconvolution. The current work is driven by the realization that the PSF can be decomposed into spatially invariant and variant components, namely the electric and geometric responses of the transducer element(s). Since the electric response acts along the axial direction, depth-independent axial deconvolution can be performed along the entire image. Moreover, since axial deconvolution effectively shapes the frequency response of the transducer, lateral resolution can also be enhanced. Using simulated and experimental data from two single element transducers (of 20, 35 MHz nominal frequencies), it is shown frequency-weighted axial deconvolution can simultaneously improve resolution in both directions. The results demonstrate a framework for improving axial and lateral resolution for ultrasound images that is unaffected by depth-dependent effects and that can balance the need for axial and lateral resolution improvement based on their relative values.
- 1 January 2017
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 32 (1) , 055002
Simultaneous enhancement of B-mode axial and lateral resolution using axial deconvolution
Enhancement of image resolution in ultrasound images is key to help clinicians end early indicators of pathological lesions. Image resolution enhancement relies on deconvolving the point spread function (PSF) of the imaging system out of the raw ultrasound image prior to envelope detection and other postprocessing steps. Unfortunately, in most cases the PSF is spatially variant, complicating its estimation and subsequent use in deconvolution. The current work is driven by the realization that the PSF can be decomposed into spatially invariant and variant components, namely the electric and geometric responses of the transducer element(s). Since the electric response acts along the axial direction, depth-independent axial deconvolution can be performed along the entire image. Moreover, since axial deconvolution effectively shapes the frequency response of the transducer, lateral resolution can also be enhanced. Using simulated and experimental data from two single element transducers (of 20, 35 MHz nominal frequencies), it is shown frequency-weighted axial deconvolution can simultaneously improve resolution in both directions. The results demonstrate a framework for improving axial and lateral resolution for ultrasound images that is unaffected by depth-dependent effects and that can balance the need for axial and lateral resolution improvement based on their relative values.
- Open Access
- 19 September 2015
- Published by Elsevier in Physics Procedia
- Vol. 70, 1195-1199
Investigation of Post-mortem Tissue Effects Using Long-time Decorrelation Ultrasound
- 19 September 2015
- Published by Elsevier in Physics Procedia
- Vol. 70, 1195-1199
Open AccessInvestigation of Post-mortem Tissue Effects Using Long-time Decorrelation Ultrasound