Kim Henrik Blomqvist
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kim Henrik Blomqvist has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
J. Lundbom
Department of Radiology, University of Helsinki and HUS Radiology (Medical Imaging Center), PO Box 340, 00027 HUS, Finland
2 shared publicationsJussi Kuutti
Aalto University
2 shared publicationsN. Lundbom
Department of Radiology, University of Helsinki and HUS Radiology (Medical Imaging Center), PO Box 340, 00027 HUS, Finland
2 shared publicationsPekka Eskelinen
Aalto University, School of Electrical Engineering, Espoo, Finland
2 shared publicationsR. E. Sepponen
Aalto University Department of Electronics, Otakaari 7B, Espoo, Finland
2 shared publicationsRaimo E Sepponen
Aalto University
2 shared publications
Latest Publications
- 25 May 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (4) , 047004
Differential photoplethysmogram sensor with an optical notch filter shows potential for reducing motion artifact signals
Objective: Photoplethysmography (PPG) has become the standard technology used in wearable health and fitness monitoring devices. Although, PPG works well at rest, trying to incorporate it for continuous monitoring is challenging, since the signal is inevitably corrupted by motion artifacts. This paper explores the feasibility of a reflective PPG sensor aiming at reducing the changes caused by motion in the non-pulsatile component of the signal, e.g., changes in venous filling. Approach: The tested sensor consisted of two back-to-back connected photodiodes and a light source with a peak wavelength around 575 nm. Additionally, the second photodiode was covered by a 575 ± 5 nm optical notch filter. Main results: When compared to standard PPG (single detector) on one test subject, the tested sensor provided 4.38 dB of attenuation for a change in venous blood during a gentle lift of upper extremity. Moreover, over 40 dB rejection was measured in the baseline resulting in a very small ‘direct current’ (DC) component. Furthermore, the baseline wander due to respiratory modulation tended to be smaller for the tested sensor. The sensor was not either susceptible for the changes in ambient light or the drift caused by the light source heating up. Significance: We believe that this is the first work that proposes the back-to-back connected photodiodes and a notch filter to reduce in-band noise in PPG. The positive results encourage to further optimize and integrate the sensor. The novelty of the method also brings new perspective to the PPG measurements.
- 25 May 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (4) , 047004
Differential photoplethysmogram sensor with an optical notch filter shows potential for reducing motion artifact signals
Objective: Photoplethysmography (PPG) has become the standard technology used in wearable health and fitness monitoring devices. Although, PPG works well at rest, trying to incorporate it for continuous monitoring is challenging, since the signal is inevitably corrupted by motion artifacts. This paper explores the feasibility of a reflective PPG sensor aiming at reducing the changes caused by motion in the non-pulsatile component of the signal, e.g., changes in venous filling. Approach: The tested sensor consisted of two back-to-back connected photodiodes and a light source with a peak wavelength around 575 nm. Additionally, the second photodiode was covered by a 575 ± 5 nm optical notch filter. Main results: When compared to standard PPG (single detector) on one test subject, the tested sensor provided 4.38 dB of attenuation for a change in venous blood during a gentle lift of upper extremity. Moreover, over 40 dB rejection was measured in the baseline resulting in a very small ‘direct current’ (DC) component. Furthermore, the baseline wander due to respiratory modulation tended to be smaller for the tested sensor. The sensor was not either susceptible for the changes in ambient light or the drift caused by the light source heating up. Significance: We believe that this is the first work that proposes the back-to-back connected photodiodes and a notch filter to reduce in-band noise in PPG. The positive results encourage to further optimize and integrate the sensor. The novelty of the method also brings new perspective to the PPG measurements.
- 12 February 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (2) , 025034
Quantification of visceral adiposity: evaluation of the body electrical loss analysis
Body electrical loss analysis (BELA) is a measurement of the electrical losses caused by the human abdomen when placed into an alternating magnetic field. This study aimed at finding a prediction formula for visceral fat area (VFA) from BELA. Thirty-eight test subjects covering the body mass index of 19.6–39.4 kg m −2 and the waist circumference of 78–128 cm underwent BELA, single-frequency electrical abdominal impedance measurement (SAI), conventional bioelectrical impedance analysis and cross-sectional magnetic resonance imaging (MRI). The BELA was compared with the amount of visceral and subcutaneous fat calculated from MR images. The strongest correlation between BELA and VFA ( r = 0.61, SEE = 59.30) was found at the height of umbilicus +5 cm, and it tended to decrease when the measurement height was lowered. The correlation to subcutaneus fat area (SFA) at the height of umbilicus +5 cm was r = 0.43 (lower is better), and it tended to increase when the measurement height was lowered. The correlation of BELA to VFA in the evaluation cohort is not strong enough to tolerate obtaining the prediction formula for VFA by regression among BELA and MRI. Also the large SEE value suggests a poor agreement with MRI. Thus the results suggest that in its current form BELA cannot be applied as a diagnostic device to measure visceral fat. Although SAI can help in identifying the abdominal SF layer thickness, it did not help when applied to BELA analysis.
- 12 February 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (2) , 025034
Quantification of visceral adiposity: evaluation of the body electrical loss analysis
Body electrical loss analysis (BELA) is a measurement of the electrical losses caused by the human abdomen when placed into an alternating magnetic field. This study aimed at finding a prediction formula for visceral fat area (VFA) from BELA. Thirty-eight test subjects covering the body mass index of 19.6–39.4 kg m −2 and the waist circumference of 78–128 cm underwent BELA, single-frequency electrical abdominal impedance measurement (SAI), conventional bioelectrical impedance analysis and cross-sectional magnetic resonance imaging (MRI). The BELA was compared with the amount of visceral and subcutaneous fat calculated from MR images. The strongest correlation between BELA and VFA ( r = 0.61, SEE = 59.30) was found at the height of umbilicus +5 cm, and it tended to decrease when the measurement height was lowered. The correlation to subcutaneus fat area (SFA) at the height of umbilicus +5 cm was r = 0.43 (lower is better), and it tended to increase when the measurement height was lowered. The correlation of BELA to VFA in the evaluation cohort is not strong enough to tolerate obtaining the prediction formula for VFA by regression among BELA and MRI. Also the large SEE value suggests a poor agreement with MRI. Thus the results suggest that in its current form BELA cannot be applied as a diagnostic device to measure visceral fat. Although SAI can help in identifying the abdominal SF layer thickness, it did not help when applied to BELA analysis.
- Open Access
Evaluation of Visitor Counting Technologies and Their Energy Saving Potential through Demand-Controlled Ventilation
Direction-sensitive visitor counting sensors can be used in demand-controlled ventilation (DCV). The counting performance of two light beam sensors and three camera sensors, all direction sensitive, was simultaneously evaluated at an indoor location. Direction insensitive sensors (two mat sensors and one light beam sensor) were additionally tested as a reference. Bidirectional counting data of free people flow was collected for 36 days in one-hour resolution, including five hours of manual counting. Compared to the manual results, one of the light beam sensors had the most equally balanced directional overall counting errors (4.6% and 5.2%). The collected data of this sensor was used to model the air transportation energy consumption of visitor counting sensor-based DCV and constant air volume ventilation (CAV). The results suggest that potential savings in air transportation energy consumption could be gained with the modeled DCV as its total daily airflow during the test period was 54% of the total daily airflow of the modeled CAV on average. A virtually real-time control of ventilation could be realized with minute-level counting resolution. Site-specific calibration of the visitor counting sensors is advisable and they could be complemented with presence detectors to avoid unnecessary ventilation during unoccupied periods of the room. A combination of CO2 and visitor counting sensors could be exploited in DCV to always guarantee sufficient ventilation with a short response time.
Open AccessEvaluation of Visitor Counting Technologies and Their Energy Saving Potential through Demand-Controlled Ventilation
Direction-sensitive visitor counting sensors can be used in demand-controlled ventilation (DCV). The counting performance of two light beam sensors and three camera sensors, all direction sensitive, was simultaneously evaluated at an indoor location. Direction insensitive sensors (two mat sensors and one light beam sensor) were additionally tested as a reference. Bidirectional counting data of free people flow was collected for 36 days in one-hour resolution, including five hours of manual counting. Compared to the manual results, one of the light beam sensors had the most equally balanced directional overall counting errors (4.6% and 5.2%). The collected data of this sensor was used to model the air transportation energy consumption of visitor counting sensor-based DCV and constant air volume ventilation (CAV). The results suggest that potential savings in air transportation energy consumption could be gained with the modeled DCV as its total daily airflow during the test period was 54% of the total daily airflow of the modeled CAV on average. A virtually real-time control of ventilation could be realized with minute-level counting resolution. Site-specific calibration of the visitor counting sensors is advisable and they could be complemented with presence detectors to avoid unnecessary ventilation during unoccupied periods of the room. A combination of CO2 and visitor counting sensors could be exploited in DCV to always guarantee sufficient ventilation with a short response time.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance of commercial over-head camera sensors in recognizing patterns of two and three persons: A case study
Accurate visitor counting is needed in the research of people flows and people distributions. A case study about the performance of four commercial direction-sensitive over-head camera sensors (Axis and Biodata video camera counters, Sick time-of-flight camera, and Irisys thermographic people counter) in detecting patterns of two and three persons was carried out. Although all the tested sensors except Axis generally performed well with the patterns of two people, error rates of even over 20% were observed with the three-person patterns. Simultaneous false positive and false negative detections also occasionally speciously improved the counting results of Axis and Sick. Due to these flaws the accuracies of the sensors do not allow reliable people flow modeling or estimation of room occupancy levels, but is sufficient e.g. for measuring the order of magnitude of customer flows. However, as there are differences between separate counting sites, the results are only indicative in general.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance of commercial over-head camera sensors in recognizing patterns of two and three persons: A case study
Accurate visitor counting is needed in the research of people flows and people distributions. A case study about the performance of four commercial direction-sensitive over-head camera sensors (Axis and Biodata video camera counters, Sick time-of-flight camera, and Irisys thermographic people counter) in detecting patterns of two and three persons was carried out. Although all the tested sensors except Axis generally performed well with the patterns of two people, error rates of even over 20% were observed with the three-person patterns. Simultaneous false positive and false negative detections also occasionally speciously improved the counting results of Axis and Sick. Due to these flaws the accuracies of the sensors do not allow reliable people flow modeling or estimation of room occupancy levels, but is sufficient e.g. for measuring the order of magnitude of customer flows. However, as there are differences between separate counting sites, the results are only indicative in general.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 185-187
Integrating performance and production oriented design of satellite oscillators
This paper is based on background research [1] in which a manufacturability analysis was carried out for of an oscillator made for 5 GHz satellite and radar bands. The electronic circuit uses two cascaded bipolar microwave transistors in an emitter feedback amplifier configuration which is combined with a cylindrical dielectric resonator. Three miniature coupling loops are included in it, one for amplifier input, one for amplifier output via a Wilkinson power divider and another for the optional tuning varactor diode. We have formulated two research questions: Firstly, how much is it possible to increase the Q-value of the resonator by improving the manufacturing quality of its milled geometries? Secondly, is it possible to describe the required manufacturing accuracy with the Q-value added to the Product Data Management (PDM) data set? This paper focuses on the multidisciplinary aspects of the integrated performance and production oriented design of satellite oscillators. For the first time, the quality characteristic (Q-value) could be utilized directly in the mechanical PDM data of an oscillator to guide production.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 185-187
Integrating performance and production oriented design of satellite oscillators
This paper is based on background research [1] in which a manufacturability analysis was carried out for of an oscillator made for 5 GHz satellite and radar bands. The electronic circuit uses two cascaded bipolar microwave transistors in an emitter feedback amplifier configuration which is combined with a cylindrical dielectric resonator. Three miniature coupling loops are included in it, one for amplifier input, one for amplifier output via a Wilkinson power divider and another for the optional tuning varactor diode. We have formulated two research questions: Firstly, how much is it possible to increase the Q-value of the resonator by improving the manufacturing quality of its milled geometries? Secondly, is it possible to describe the required manufacturing accuracy with the Q-value added to the Product Data Management (PDM) data set? This paper focuses on the multidisciplinary aspects of the integrated performance and production oriented design of satellite oscillators. For the first time, the quality characteristic (Q-value) could be utilized directly in the mechanical PDM data of an oscillator to guide production.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 64 (17363705) , 199-202
An open-source hardware for electrical bioimpedance measurement
This paper describes open-source hardware to measure both the magnitude and phase of the electrical bioimpedance in a frequency range from few kilohertz up to 100 kHz by using a four-electrode technique. The amount of current injected and the sensitivity of the system can be set to the desired range by changing the front-end resistor values. The system can be easily built and adapted with the help of the design details made available at GitHub. The practical performance was evaluated in abdominal impedance measurement, which was the primary motivation to build the system. Other experiments were performed with a 2R-1C circuit, a 10-Ω resistor, and a 100-nF capacitor, with observed relative errors in the impedances of -0.73 ± 0.34 %, -2.47 ± 1.43 % and -8.81 ± 0.64 % (mean ± SD), respectively, from 10 kHz to 100 kHz.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 64 (17363705) , 199-202
An open-source hardware for electrical bioimpedance measurement
This paper describes open-source hardware to measure both the magnitude and phase of the electrical bioimpedance in a frequency range from few kilohertz up to 100 kHz by using a four-electrode technique. The amount of current injected and the sensitivity of the system can be set to the desired range by changing the front-end resistor values. The system can be easily built and adapted with the help of the design details made available at GitHub. The practical performance was evaluated in abdominal impedance measurement, which was the primary motivation to build the system. Other experiments were performed with a 2R-1C circuit, a 10-Ω resistor, and a 100-nF capacitor, with observed relative errors in the impedances of -0.73 ± 0.34 %, -2.47 ± 1.43 % and -8.81 ± 0.64 % (mean ± SD), respectively, from 10 kHz to 100 kHz.
- 1 April 2011
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 22 (5)
Instrumentation amplifier implements second-order active low-pass filter with high gain factor
- 1 April 2011
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 22 (5)
Instrumentation amplifier implements second-order active low-pass filter with high gain factor
- Open Access
- 1 January 2011
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 10 (1) , 98
Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration
Body electrical loss analysis (BELA) is a new non-invasive way to assess visceral fat depot size through the use of electromagnetism. BELA has worked well in phantom measurements, but the technology is not yet fully validated. Ten volunteers (5 men and 5 women, age: 22-60 y, BMI: 21-30 kg/m2, waist circumference: 73-108 cm) were measured with the BELA instrument and with cross-sectional magnetic resonance imaging (MRI) at the navel level, navel +5 cm and navel -5 cm. The BELA signal was compared with visceral and subcutaneous fat areas calculated from the MR images. The BELA signal did not correlate with subcutaneous fat area at any level, but correlated significantly with visceral fat area at the navel level and navel +5 cm. The correlation was best at level of navel +5 cm (R2 = 0.74, P < 0.005, SEE = 29.7 cm2, LOOCV = 40.1 cm2), where SEE is the standard error of the estimate and LOOCV is the root mean squared error of leave-one-out style cross-validation. The average estimate of repeatability of the BELA signal observed through the study was ±9.6 %. One of the volunteers had an exceptionally large amount of visceral fat, which was underestimated by BELA. The correlation of the BELA signal with the visceral but not with the subcutaneous fat area as measured by MRI is promising. The lack of correlation with the subcutaneous fat suggests that subcutaneous fat has a minor influence to the BELA signal. Further research will show if it is possible to develop a reliable low-cost method for the assessment of visceral fat either using BELA only or combining it, for example, with bioelectrical impedance measurement. The combination of these measurements may help assessing visceral fat in a large scale of body composition. Before large-scale clinical testing and ROC analysis, the initial BELA instrumentation requires improvements. The accuracy of the present equipment is not sufficient for such new technology.
- 1 January 2011
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 10 (1) , 98
Open AccessBody electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration
Body electrical loss analysis (BELA) is a new non-invasive way to assess visceral fat depot size through the use of electromagnetism. BELA has worked well in phantom measurements, but the technology is not yet fully validated. Ten volunteers (5 men and 5 women, age: 22-60 y, BMI: 21-30 kg/m2, waist circumference: 73-108 cm) were measured with the BELA instrument and with cross-sectional magnetic resonance imaging (MRI) at the navel level, navel +5 cm and navel -5 cm. The BELA signal was compared with visceral and subcutaneous fat areas calculated from the MR images. The BELA signal did not correlate with subcutaneous fat area at any level, but correlated significantly with visceral fat area at the navel level and navel +5 cm. The correlation was best at level of navel +5 cm (R2 = 0.74, P < 0.005, SEE = 29.7 cm2, LOOCV = 40.1 cm2), where SEE is the standard error of the estimate and LOOCV is the root mean squared error of leave-one-out style cross-validation. The average estimate of repeatability of the BELA signal observed through the study was ±9.6 %. One of the volunteers had an exceptionally large amount of visceral fat, which was underestimated by BELA. The correlation of the BELA signal with the visceral but not with the subcutaneous fat area as measured by MRI is promising. The lack of correlation with the subcutaneous fat suggests that subcutaneous fat has a minor influence to the BELA signal. Further research will show if it is possible to develop a reliable low-cost method for the assessment of visceral fat either using BELA only or combining it, for example, with bioelectrical impedance measurement. The combination of these measurements may help assessing visceral fat in a large scale of body composition. Before large-scale clinical testing and ROC analysis, the initial BELA instrumentation requires improvements. The accuracy of the present equipment is not sufficient for such new technology.
- 1 January 2011
- Published by Springer Nature in IFMBE Proceedings
- p. 66-69
Body Electrical Loss Analysis (BELA) – An Electromagnetic Method for the Assessment of Abdominal Visceral Fat Accumulation
- 1 January 2011
- Published by Springer Nature in IFMBE Proceedings
- p. 66-69
Body Electrical Loss Analysis (BELA) – An Electromagnetic Method for the Assessment of Abdominal Visceral Fat Accumulation
- Open Access
- 1 January 2010
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 9 (1) , 65
A feasibility study of altered spatial distribution of losses induced by eddy currents in body composition analysis
Tomographic imaging has revealed that the body mass index does not give a reliable state of overall fitness. However, high measurement costs make the tomographic imaging unsuitable for large scale studies or repeated individual use. This paper reports an experimental investigation of a new electromagnetic method and its feasibility for assessing body composition. The method is called body electrical loss analysis (BELA). The BELA method uses a high-Q parallel resonant circuit to produce a time-varying magnetic field. The Q of the resonator changes when the sample is placed in its coil. This is caused by induced eddy currents in the sample. The new idea in the BELA method is the altered spatial distribution of the electrical losses generated by these currents. The distribution of losses is varied using different excitation frequencies. The feasibility of the method was tested using simplified phantoms. Two of these phantoms were rough estimations of human torso. One had fat in the middle of its volume and saline solution in the outer shell volume. The other had reversed conductivity distributions. The phantoms were placed in the resonator and the change in the losses was measured. Five different excitation frequencies from 100 kHz to 200 kHz were used. The rate of loss as a function of frequency was observed to be approximately three times larger for a phantom with fat in the middle of its volume than for one with fat in its outer shell volume. At higher frequencies the major signal contribution can be shifted toward outer shell volume. This enables probing the conductivity distribution of the subject by weighting outer structural components. The authors expect that the loss changing rate over frequency can be a potential index for body composition analysis.
- 1 January 2010
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 9 (1) , 65
Open AccessA feasibility study of altered spatial distribution of losses induced by eddy currents in body composition analysis
Tomographic imaging has revealed that the body mass index does not give a reliable state of overall fitness. However, high measurement costs make the tomographic imaging unsuitable for large scale studies or repeated individual use. This paper reports an experimental investigation of a new electromagnetic method and its feasibility for assessing body composition. The method is called body electrical loss analysis (BELA). The BELA method uses a high-Q parallel resonant circuit to produce a time-varying magnetic field. The Q of the resonator changes when the sample is placed in its coil. This is caused by induced eddy currents in the sample. The new idea in the BELA method is the altered spatial distribution of the electrical losses generated by these currents. The distribution of losses is varied using different excitation frequencies. The feasibility of the method was tested using simplified phantoms. Two of these phantoms were rough estimations of human torso. One had fat in the middle of its volume and saline solution in the outer shell volume. The other had reversed conductivity distributions. The phantoms were placed in the resonator and the change in the losses was measured. Five different excitation frequencies from 100 kHz to 200 kHz were used. The rate of loss as a function of frequency was observed to be approximately three times larger for a phantom with fat in the middle of its volume than for one with fat in its outer shell volume. At higher frequencies the major signal contribution can be shifted toward outer shell volume. This enables probing the conductivity distribution of the subject by weighting outer structural components. The authors expect that the loss changing rate over frequency can be a potential index for body composition analysis.