Lorenzo Massimi

Lorenzo Massimi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lorenzo Massimi has a total of 173 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Insulin fails to mitigate amyloid pathology but modulates intestinal morphology in the 5xFAD model revealed by synchrotron-based XPCT

    by Esra Ayan, Francesca Palermo, Giorgia Cavioli, Sevginur Bostan, Busra Zuleyha Dogan, Kader Kilic, Arife Ahsen Kaplan, Inna Bukreeva, Lorenzo Massimi, Elena Longo, et al.

    Intranasal insulin has been investigated as a metabolic intervention in Alzheimer’s disease (AD), but its effects across the brain–gut axis remain unclear. We combined multiscale synchrotron X-ray phase-contrast tomography (XPCT), amyloid-β immunofluorescence, and fecal metaproteomics to examine structural and molecular responses in 5xFAD mice. Twenty-four mice representing wild-type and 5xFAD genotypes, saline and insulin conditions, and terminal ages of 2 and 6 months received insulin at 1 U/mouse/day for 5 weeks. Micro-XPCT visualized plaque-like deposits, nanoXPCT revealed their heterogeneous internal organization, and MOAB-2 labeling provided qualitative support for amyloid pathology. Detectable plaque burden was not lower after treatment: deposits occurred in two of three treated versus none of three untreated 5xFAD mice at 2 months, and treated animals had higher descriptive regional means at 6 months. In the ileum, insulin was associated with lower villus length and crypt depth in 6-month-old 5xFAD mice, whereas no significant differences were detected at 2 months. Fecal profiles retained broad taxonomic overlap but differed in functional annotations, with hydrolase-associated fractions of 81%, 92%, 96%, and 93% across untreated wild-type, treated wild-type, untreated 5xFAD, and treated 5xFAD conditions, respectively, within the selected peptide subset. Thus, lower ileal dimensions coexisted with non-reduced detectable brain plaque burden and a fecal protein profile distinct from untreated wild type. Together, these findings reveal contrasting central and peripheral patterns following intranasal insulin treatment in 5xFAD mice: no detectable reduction in cerebral plaque burden, alongside attenuation of selected ileal structural alterations and distinct fecal metaproteomic profiles. Although exploratory, the findings raise the possibility that intranasal insulin alters amyloid compartmentalization or plaque detectability rather than promoting amyloid clearance, while producing distinct peripheral remodeling.

  • Open Access

    Retrieval of multiple fibre orientations using X-ray dark-field signal modelling

    by Lorenzo Massimi, Michela Fratini, Shashidhara Marathe, Christoph Rau, Giuseppe Gigli, Alessandro Olivo, Alessia Cedola

  • Open Access

    Multi-parametric µMRI and Synchrotron radiation-based XPCT for studying human bone tissue in archaeological contexts

    by Francesca Palermo, Martina Trocchi, Michela Fratini, Inna Bukreeva, Lorenzo Massimi, Alfredo Coppa, Alessia Cedola, Silvia Capuani


  • Open Access

    Optimising sample preparation to enhance contrast-to-noise ratio in X-ray phase contrast tomography white matter (WM) imaging of the central nervous system

    by Michela Fratini, Lorenzo Massimi, Francesco Brun, Darren Batey, Inna Bukreeva, Alberto Mittone, Alberto Bravin, Elena Longo, Giuliana Tromba, Federico Giove, et al.

    The choice of fixative is critical in X-ray phase-contrast tomography (XPCT) because it affects tissue preservation, contrast enhancement and compatibility with other imaging techniques. A careful selection and optimization of fixatives can lead to significant improvements in the quality and accuracy of imaging results, which is especially important when studying complex biological systems such as those involved in neurodegeneration, where it is crucial to maintain the fine details of the Grey Matter (GM) and White Matter (WM) structures. Dehydration with ethanol and xylene is commonly used as it effectively removes water while minimising structural alterations. Using perfusion in ethanol and dehydration in xylene as a secondary fixative can increase the contrast, thereby improving the visibility of myelinated fibers without using a contrast agent. In this paper we discuss an optimised fixation method to significantly enhance the contrast and boost the signal to noise ratio (SNR) in XPCT images of WM in the central nervous system (CNS).


  • Open Access

    Investigating gut alterations in Alzheimer’s disease: In-depth analysis with micro- and nano-3D X-ray phase contrast tomography

    by Francesca Palermo, Nicole Marrocco, Letizia Dacomo, Elena Grisafi, Viviana Moresi, Alessia Sanna, Lorenzo Massimi, Marianna Musella, Laura Maugeri, Inna Bukreeva, et al.

    Alzheimer’s disease (AD), a debilitating neurodegenerative disorder, remains one of the foremost public health challenges affecting more than 30 million people worldwide with the etiology still largely enigmatic. The intricate gut-brain axis, serving as a vital communication network between the gut and the brain, appears to wield influence in the progression of AD. Our study showcases the remarkable precision of x-ray phase-contrast tomography (XPCT) in conducting an advanced three-dimensional examination of gut cellular composition and structure. The exploitation of micro- and nano-XPCT on various AD mouse models unveiled relevant alterations in villi and crypts, cellular transformations in Paneth and goblet cells, along with the detection of telocytes, neurons, erythrocytes, and mucus secretion by goblet cells within the gut cavity. The observed gut structural variations may elucidate the transition from dysbiosis to neurodegeneration and cognitive decline. Leveraging XPCT could prove pivotal in early detection and prognosis of the disease.


  • Open Access

    T staging esophageal tumors with x rays

    by Tom Partridge, Paul Wolfson, Jinxing Jiang, Lorenzo Massimi, Alberto Astolfo, Nargiza Djurabekova, Savvas Savvidis, Charlotte Maughan Jones, Charlotte Hagen, E. Millard, et al.

    With histopathology results typically taking several days, the ability to stage tumors during interventions could provide a step change in various cancer interventions. X-ray technology has advanced significantly in recent years with the introduction of phase-based imaging methods. These have been adapted for use in standard labs rather than specialized facilities such as synchrotrons, and approaches that enable fast 3D scans with conventional x-ray sources have been developed. This opens the possibility to produce 3D images with enhanced soft tissue contrast at a level of detail comparable to histopathology, in times sufficiently short to be compatible with use during surgical interventions. In this paper we discuss the application of one such approach to human esophagi obtained from esophagectomy interventions. We demonstrate that the image quality is sufficiently high to enable tumor T staging based on the x-ray datasets alone. Alongside detection of involved margins with potentially life-saving implications, staging tumors intra-operatively has the potential to change patient pathways, facilitating optimization of therapeutic interventions during the procedure itself. Besides a prospective intra-operative use, the availability of high-quality 3D images of entire esophageal tumors can support histopathological characterization, from enabling “right slice first time” approaches to understanding the histopathology in the full 3D context of the surrounding tumor environment.


  • Open Access

    Quantification of porosity in composite plates using planar X-ray phase contrast imaging

    by D. Shoukroun, L. Massimi, M. Endrizzi, A. Nesbitt, D. Bate, P. Fromme, A. Olivo


  • Open Access

    Modulation transfer function (MTF) evaluation for x-ray phase imaging system employing attenuation masks

    by Glafkos Havariyoun, Lorenzo Massimi, Charlotte Hagen, Marco Endrizzi, Alessandro Olivo

    Objective. Attenuation masks can be used in x-ray imaging systems to increase their inherent spatial resolution and/or make them sensitive to phase effects, a typical example being Edge Illumination x-ray phase contrast imaging (EI-XPCI). This work investigates the performance of a mask-based system such as EI-XPCI in terms of Modulation Transfer Function (MTF), in the absence of phase effects. Approach . Pre-sampled MTF measurements, using an edge, were performed on the same system implemented without masks, with non-skipped masks and finally with skipped masks (i.e. masks in which apertures illuminate every other pixel row/column). Results are compared to simulations and finally images of a resolution bar pattern acquired with all the above setups are presented. Main results . Compared to the detector’s inherent MTF, the non-skipped mask setup provides improved MTF results. In comparison to an ideal case where signal spill-out into neighbouring pixels is negligible, this improvement takes place only at specific frequencies of the MTF, dictated by the spatial repetition of the spill-out signal. This is limited with skipped masks, which indeed provide further MTF improvements over a larger frequency range. Experimental MTF measurements are supported through simulation and resolution bar pattern images. Significance . This work has quantified the improvement in MTF due to the use of attenuation masks and lays the foundation for how acceptance and routine quality control tests will have to be modified when systems using masks are introduced in clinical practice and how MTF results will compare to those of conventional imaging systems.


  • Open Access

    Time resolved in-situ multi-contrast X-ray imaging of melting in metals

    by Lorenzo Massimi, Samuel J. Clark, Sebastian Marussi, Adam Doherty, Saurabh M. Shah, Joachim Schulz, Shashidhara Marathe, Christoph Rau, Marco Endrizzi, Peter D. Lee, et al.

    In this work, the application of a time resolved multi-contrast beam tracking technique to the investigation of the melting and solidification process in metals is presented. The use of such a technique allows retrieval of three contrast channels, transmission, refraction and dark-field, with millisecond time resolution. We investigated different melting conditions to characterize, at a proof-of-concept level, the features visible in each of the contrast channels. We found that the phase contrast channel provides a superior visibility of the density variations, allowing the liquid metal pool to be clearly distinguished. Refraction and dark-field were found to highlight surface roughness formed during solidification. This work demonstrates that the availability of the additional contrast channels provided by multi-contrast X-ray imaging delivers additional information, also when imaging high atomic number specimens with a significant absorption.


  • Replacing the detector mask with a structured scintillator in edge-illumination x-ray phase contrast imaging

    by Lorenzo Massimi, Gibril K. Kallon, Ian Buchanan, Marco Endrizzi, Piotr Dobrosz, Rob Brooks, Daniel Brau, Ed Bullard, Alessandro Olivo

    We present a proof-of-concept edge illumination x-ray phase contrast system where the detector mask has been replaced by an indirect conversion detector in which sensitive and insensitive regions have been obtained by “patterning” the scintillator. This was achieved by creating a free-standing grid with period and aperture size matching that of a typical detector mask and filling the apertures with gadolinium oxysulfide. Images of various samples were collected with both the modified and the original edge illumination systems based on the use of two masks to characterize the performances of this detector design. We found that, despite the proof-of-concept nature of this attempt resulting in a structured detector with suboptimal performance, it allows effective separation of the attenuation and refraction channels through phase retrieval and the visualization of hard-to-detect features such as cartilage through the latter channel, thus demonstrating that the proposed approach holds the potential to lead to improved stability since it will use a single optical element facilitating the design of rotating phase contrast systems or the retrofitting of conventional x-ray systems.