MJMilica Jovčevski

Milica Jovčevski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Milica Jovčevski has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optimization of the electrostatic precipitators in unit A1 of the Kostolac A thermal power plant

    by Zoran Marković, Milić Erić, Aleksandar Milićević, Rastko Jovanović, Nikola Živković, Ivan Lazović, Milica Jovčevski

    The plate-wire electrostatic precipitator (ESP) achieves maximum efficiency by simultaneously generating the maximum spark voltage via a homogeneous velocity field of the flue gas between the plates. The consortium, consisting of the Vinča Institute of nuclear sciences and the Nikola Tesla Electrotechnical Institute, has successfully developed and applied new measuring equipment and the original methodology for diagnosing the actual working conditions and optimization of the ESP. This paper presents the results of testing and optimization of the ESP of the Kostolac A thermal power plant unit A1. Based on the results of measurements of particulate emissions, flue gas velocity distribution in the flue ducts and chambers of the ESP, the reconstruction of the mechanical turning and damping elements of the ESP and the installation of new power control elements have been proposed. The effectiveness of the proposed measures can be seen in the improvement of the homogeneity parameters of the velocity distribution in the vertical cross-sections in the front of the first and behind the last electric field of the electrostatic precipitator.

  • Open Access

    Experimental research of the lignite drying process in packed bed

    by Milić Erić, Zoran Marković, Aleksandar Milićević, Rastko Jovanović, Danka Kostadinović, Ivan Lazović, Milica Jovčevski

    One of the biggest challenges is the development of low-carbon technologies for coal utilization. Clean coal technologies are a group of measures aimed at reducing carbon dioxide emissions by increasing the energy efficiency of coal-fired power plants. Experimental studies were carried out on the convective drying of lignite. The drying process was investigated under the packed bed conditions. The effects of sample size, temperature and coal grain size on the drying rate were investigated. Temperature was recognized as the most influential parameter.

  • Open Access

    Mathematical and CFD methods for prediction of thermal pollution caused by thermal power plant

    by Milica Jovcevski, Mirjana Lakovic, Iliya Iliev, Milos Banjac, Filip Stojkovski, Marko Mancic

    Wastewaters from power plants is a major concern for environmental protection. After the water is used in thermal power plant, the heated effluent is again discharged in the same water body from where it is taken. This not only disturbs the aquatic life but also affects the balance of the ecosystem. This paper presents the background of the thermal pollution, modelling approach and analysis methods for prediction of thermal pollution. A 2-D model of Sava River is discussed. The thermal power plant Nikola Tesla B was considered. Analysis of thermal discharge into the Sava River for the twelve-year period has been carried out. It was done a comparative analysis of the results obtained using mathematical (Electricity of France ? EDF) method and numerical analysis using the CFD software package ANSYS FLUENT. A comparison of these two methods was made in order to show that it is possible to predict thermal pollution precisely and that it is possible to apply these methods in the design of industrial plants and not only in large thermal power plants. Finally, the results showed the matching of the obtained values at greater distances from the water outlet of the thermal power plant.


  • Open Access

    RELATIONSHIP BETWEEN THERMAL POLLUTION AND IMPACT OF OUTLET ANGLE OF THE THERMAL DISCHARGE

    by Milica Jovčevski, Mirjana Laković, Filip Stojkovski, Milica Ivanović

    Predicting the behavior of thermal discharges from power plants under different outlet angles of the thermal discharge was done. The operation of power plant Nikola Tesla B was considered. This power plant has a once-through cooling system and uses the Sava River as a natural water cooling system. For numerical simulation, Ansys Fluent software package was used. Five positions of the channel discharge angle were considered. A two-dimensional model was developed and the k-ε turbulence model was applied. During the analysis, the values of maximum temperatures generated by pouring the discharge channel were considered. Also, the size of the field affected by this type of pollution was observed. The obtained data as a result of numerical simulation can be used to study problems associated with the mixing of heated water discharged from thermal power plants into the river flow. With this study, it is possible to reduce the impact of thermal pollution from the power plant by selecting an adequate outlet angle for the thermal discharge channel.


  • Improving the energy efficiency of a 110 MW thermal power plant by low-cost modification of the cooling system

    by Milica Jović, Mirjana Laković, Miloš Banjac

    The electric power system of the Republic of Serbia relies mostly on lignite-fired thermal power plants, with 70% of the total electricity generation. Most of these plants are over 30 years old, and investment in their modernization is necessary. The energy efficiency of the 110 MW coal-fired power plant in which the condenser is cooled by the mechanical draught wet cooling towers system is analyzed in this paper. Attention is primarily devoted to operating conditions of the cold end of the plant, i.e. to the interrelationship of the condenser and cooling towers. Most important parameters that affect the operation of the cooling towers system are ambient air temperature and relative humidity, specific mass flow rate, and temperature of cooled water. With the existing cooling system, the overall energy efficiency of the plant is low, especially in the summer months, even less than 30%, due to adverse weather conditions. By upgrading existing cooling tower system by adaptation of two additional cooling tower cells, overall energy efficiency can be increased by 1.5%. The cooling tower system rehabilitation investments payback period is estimated to be less than one year. Static method for economic and financial assessment is used.


  • Boiler for combustion fuel in a fluidized bed

    by Mirjana Lakovic, Milica Jovic, Branislav Stojanovic

    Fuel combustion in fluidized bed combustion is a process that is current and which every day gives more attention and there are many studies that have been closely associated with this technology. This combustion technology is widespread and constantly improving the range of benefits it provides primarily due to reduced emissions. This paper presents the boilers for combustion in a fluidized bed, whit characteristics and advantages. Also is shown the development of this type of boilers in Republic of Serbia. In this paper is explained the concept of fluidized bed combustion. Boilers for this type of combustion can be improved and thereby increase their efficiency level. More detailed characteristics are given for boilers with bubbling and circulating fluidized bed as well as their mutual comparison.