Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Corina Maria Diniș has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Gabriel Nicolae Popa

    Department of Electrical Engineering and Industrial Informatics, Politehnica University of Timișoara, 5 Revolution Street, 331128 Hunedoara, Romania

    8 shared publications
  • G N Popa

    Politehnica University of Timisoara, Department of Electrical Engineering and Industrial Informatics, 5 Revolution Street, Hunedoara, 331128, Romania

    6 shared publications
  • A Iagăr

    Politehnica University of Timisoara, Department of Electrical Engineering and Industrial Informatics, 5 Revolution Street, Hunedoara, 331128, Romania

    4 shared publications
  • Angela Iagăr

    Politehnica University of Timisoara, Department of Electrical Engineering and Industrial Informatics, 5 Revolution Street, Hunedoara, 331128, Romania

    3 shared publications
  • C D Cunţan

    Politehnica University of Timisoara, Department of Electrical Engineering and Industrial Informatics, 5 Revolution Street, Hunedoara, 331128, Romania

    2 shared publications
  • A Lagăr

    Politehnica University of Timisoara, Department of Electrical Engineering and Industrial Computer Science, Hunedoara, Romania

    1 shared publication

Latest Publications

  • Open Access

    Comparative Analysis Between Cylindrical-Type Electrostatic Precipitators Used in Household Applications

    by Gabriel Nicolae Popa, Lucian Dăscălescu, Corina Maria Diniș

    It is well known that micrometre-sized particulate matter from burning boilers represents an important health hazard for humans and animals. In this article, a few designs of cylindrical-type electrostatic precipitators (an element has a 354 mm-long aluminium cylinder with 40 mm inner diameter without and with reduced cross-section; 0.16 mm diameter for copper discharge wire) that can be used at the output of household low-power boilers (up to 50 kW) that burn coal are investigated. Negative DC high-voltage energisation (up to 14 kV) and negative pulsed energisation (up to 15 kV at different frequencies: 120, 200, and 280 Hz, using a mechanical rotary spark-gap) of the designs of electrostatic precipitators was provided to measure current and voltage shapes, current through precipitators at different speeds of gas, and dust collection when single or multiple disperser at the inlet of precipitators. A chemical analysis, electrical resistivity, and radioactivity of the collected dust are investigated. The experimental results about collection efficiency with different types of precipitator supplied with DC high-voltage and high-voltage pulses show the collection efficiency was better (2 to 13%, depending on the type of the precipitator and the input distributors) for precipitators with reduced cross-section of the collecting electrode and when the same type of precipitator in conditions of dust that has high electric resistivity.

  • Open Access

    Analogue Computation Converter for Nonhomogeneous Second-Order Linear Ordinary Differential Equation

    by Gabriel Nicolae Popa, Corina Maria Diniș

    Among many other applications, electronic converters can be used with sensors with analogue outputs (DC voltage). This article presents an analogue computation converter with two DC voltages at the inputs (one input changes the frequency of the output signal, another input changes the amplitude of the output signal) that provide a periodic sinusoidal signal (with variable frequency and amplitude) at the output. On the basis of the analogue computation converter is a nonhomogeneous second-order linear ordinary differential equation which is solved analogically. The analogue computation converter consists of analogue multipliers and operational amplifiers, composed of seven function circuits: two analogue multiplication circuits, two analogue addition circuits, one non-inverting amplifier, and two integration circuits (with RC time constants). At the output of an oscillator is a sinusoidal signal which depends on the DC voltages applied on two inputs (0 ÷ 10 V): at one input, a DC voltage is applied to linearly change the sinusoidal frequency output (up to tens of kHz, according to two time constants), and at the other input, a DC voltage is applied to linearly change the amplitude of the oscillator output signal (up to 10 V). It can be used with sensors which have a DC output voltage and must be converted to a sine wave signal with variable frequency and amplitude with the aim of transmitting information over longer distances through wires. This article presents the detailed theory of the functioning, simulations, and experiments of the analogue computation converter.

  • Open Access

    About the Aged Degradation of the Materials Used for Medium-Voltage Distributors

    by Gabriel Nicolae Popa, Dimitar Aleksiev Nikolov, Corina Maria Diniș

    The medium-voltage components in the ignition installations for gasoline engines contain electroinsulating materials that lose their properties over time. The purpose of this paper is to measure and analyze the insulation resistance, dielectric absorption ratio and polarization index of the insulation of materials (three types of materials) used for medium-voltage distributors, for several operating periods, in automotive ignition installations. Experiments were conducted with old (operation tens of thousands of km, some with surfaces that have been cleaned) and new medium-voltage distributors, and a megohmmeter was used to measure, over time, the insulation resistance between the central terminal and the output terminals at different test voltages. The insulation resistance of the distributors depends on the use: in the old ones, they have values of tens of GΩ (e.g., up to 100 GΩ) and, in the new ones, of the order of TΩ (e.g., 4–7 TΩ). The more distributors are used, for the same distributor, there are greater differences between the measurements made between terminals and the average values (87% for used distributors, respectively, 2% for new ones). For new or less used distributors, higher values were obtained for the dielectric absorption ratio (1.26–1.27; for used ones, 0.91–0.95) and polarization index (1.15–1.25; for used ones, 0.96–1.15). The results show the importance of the volume insulation resistance of the electroinsulating material compared to the surface resistance and the insignificant improvement when cleaning the internal and external surfaces of the medium-voltage distributors.


  • Open Access

    An Experimental Analysis of Three-Phase Low-Voltage Power Factor Controllers Used in a Deforming Regime

    by Corina Maria Diniș, Gabriel Nicolae Popa

    In industry, to improve the power factor in low-voltage power substations, a power factor controller (the most used method) can be installed which connects capacitors banks (connected, or not, with coils) in the electrical installation. The most important parameters of power engineering are the power factors that indicate the efficiency of energy use. Currently, many non-linear consumers (more single-phase than three-phase) are used on low voltages. Harmonics (currents and/or voltages) are the most important dynamic component of power quality, affecting electrical equipment performance and also reducing power factors. The purpose of this analysis is to increase the displacement power factor and to decrease the total harmonic distortion (for the current) in the conditions where there are linear and non-linear consumers, where the power factor must be improved with capacitors banks. Relevant different consumers have been selected for both the industry and the home sector, as follows: inductive motors that are linear, inductive consumers, compact fluorescent lamps that are non-linear, and capacitive consumers. This analysis was carried out depending on the number of steps used for the power factor controller, the values of the capacitors banks, the AC reactor (connected in series with all consumers), and the LC shunt filters. For a slight deformation regime, a large number of capacitors banks with different values ensure a finer adjustment of the displacement factor. The maximum number of steps that regulators can command should not necessarily be used (the reliability of the installation decreases with the increase in the number of capacitors banks), but a reduced number of steps can be used, which can lead to higher values of displacement power factors. To improve the deforming regime and to increase the displacement power factor, the use of LC shunt filters, connected to a small number of steps, will also increase the displacement power factor (over 0.9) and decrease the total harmonic distortion (up to 7–10%) for the current. Weaker results were obtained with AC reactors connected to the power supply phases of consumers and, if a larger number of stages were used, to which LC shunt filters were connected, these filters become difficult to calibrate (resonances occur).


  • Open Access

    Aspects Regarding of Passive Filters Sustainability for Non-Linear Single-Phase Consumers

    by Corina Maria Diniș, Gabriel Nicolae Popa, Corina Daniela Cunțan, Angela Iagăr

    The efficient use of electrical energy (an important component of sustainability) has become increasingly important for electrical consumers (industrial and non-industrial) as we face the challenges of climate change and the need to protect the environment. This theme is essential for guaranteeing a secure and sustainable future for both present and future generations. The power quality and the efficiency of electrical energy are connected to each other. Some power quality problems are caused by natural and unpredictable events, but many disturbances affecting power quality are caused by suppliers and consumers. One of the most important parameters in power engineering is the power factor, which indicates the degree of efficient use of electrical energy. Harmonics is the most important dynamic component of power quality, which affects the operation of electrical equipment and, at the same time, reduces the power factor. Harmonic sources in power systems are generally associated with nonlinear loads. To analyze the operating of passive filters (series L, shunt LC, T type LCL), two groups of experiments (relevant consumers were chosen for the industry as well as from the household sector) were carried out with single-phase nonlinear consumers: in the first group of experiments, a variable-frequency drive is used to supply a three-phase induction motor with variable load; in the second group of experiments, compact fluorescent lamps and LED lamps were used. Following the experiments, it was found that the difficulty of calibrating coils (to size a filter), especially the coils with a core, and the change in electrical properties over time for capacitors. For a certain type of consumer, the improvement of the current waveform depends on the type of filter used, the possibility of improving the power factor (to use electrical energy efficiently), and the role of the source impedance, which is particularly important to improve the efficiency of passive filters. Through the appropriate choice of the passive filter, a decrease in the deforming regime is obtained, with a slight decrease in the active power, and by increasing the power factor, a decrease in the losses of electrical energy from the electrical networks is obtained, with direct implications for the emission of greenhouse gases.


  • Open Access

    Low-Cost System with Transient Reduction for Automatic Power Factor Controller in Three-Phase Low-Voltage Installations

    by Gabriel Nicolae Popa, Corina Maria Diniș

    In power engineering, the importance of maintaining a high power factor in low-voltage electrical installations is known. In power substations for industry, the usual method of coupling is to use an automatic power factor controller which connects capacitors banks (with electromagnetic contactors). Sometimes, AC reactors are connected to the phases of the capacitors banks (to reduce transient phenomena and the deforming regime), depending on the desired value of the power factor. This paper presents an analysis (more focused on experimentation) of a low-cost system for automatic regulation of the power factor with a reduction in transients and an increase in the life of contactors (eliminating the electric arc during switching on), with capacitors banks for low-voltage three-phase installations that connect the capacitors banks by means of one three-phase solid-state relay (an expensive device for a quality device; one is used for all capacitors banks) and using several electromagnetic contactors. The automatic power factor adjustment system has a controller with a microprocessor with six outputs, controlled by the phase shift between the current (measured with a current transformer proportional to the current in a bar) and the phase voltage, which is part of a system of distribution bars (L1,2,3, N) from which electrical consumers (e.g., induction motors) are supplied. To reduce transients when connecting capacitors banks, a three-phase solid-state relay and two related electromagnetic contactors are used for each capacitors bank. The automatic power factor controller is connected to two low-capacity PLCs that control the logic of connecting the capacitors banks to reduce transients. By using the proposed regulation system, a cheaper control solution is obtained compared to the use of one solid-state relay for each capacitors banks, under the conditions in which the power factor adjustment is made as in the classic solution. If twelve capacitors banks are used, the proposed installation is 22.57% cheaper than the classical power factor regulation installation.


  • Open Access

    Investigations on Three-Section Plate-Type Electrostatic Precipitators Used in Thermoelectric Power Plants

    by Gabriel Nicolae Popa, Corina Maria Diniș, Angela Iagăr

    Dust emissions must be managed and reduced as much as possible to safeguard the environment and human health. Plate-type electrostatic precipitators have been used to decrease pollution in a number of sectors, particularly for applications needing massive volumes of gas to be dedusted at high dust concentrations and temperatures. This paper examines large-capacity plate-type electrostatic precipitators with three sections used in a coal-fired thermal power plant. Using simulations and experiments, the collection efficiency (in different ways of supplying sections, without and with sections rapping), the influence of dust resistivity and a dust layer on the surfaces of collection electrodes, the electrical parameters (voltage, current density, and space charge density) for the sections of the electrostatic precipitators, and the electrical parameters of the power sources (voltage, current, power, and power factor) are studied. A higher dust resistivity will cause a change in the shape of the voltage delivered to the sections, an increase in the average voltage from sections, and a decrease in collecting efficiency (by a few percent). A greater degree of intermittence alters the current-voltage characteristics of the sections, decreases the current across the sections, and improves collection efficiency. The density of space charges increases with the degree of intermittency and is highest at the input section. With increasing thickness of the dust layer on the collection electrodes, the collection efficiency increases. PM10 dust particles (which have a lower migration speed) are the hardest to collect with ESPs. When the sections are rapping, PM 20–30 dust particles are more difficult to collect because their migration speeds decrease significantly (compared to the situation when the sections are not rapping). The operation of the power sources of the ESP sections is dynamic, being controlled by the regulators, and the current (or current density), depending on the voltage characteristics, changes permanently (at intervals of a few seconds). The power sources of the sections are deforming consumers (the current is much different from the sinusoidal form).


  • Open Access

    Power factor measuring device using microcontroller for single-phase consumers

    by C M Diniş, G N Popa, A Iagăr

    The paper presents a device with microcontroller for measuring the power factor used for single-phase low voltage electrical consumers. Voltage and current are measured, and the paper presents two constructive variants of pulse circuits (TTL compatible) used to measure the phase-shift between current and voltage. In the first constructive variant, without galvanic separation, the voltage measurement is performed with a voltage divider connected in parallel with the consumer, and the current measurement is made by a shunt resistor connected in series with the consumer. In the second construction variant, with galvanic separation, the voltage is measured by a step-down voltage transformer, and the current is measured with a current transformer that has a load resistance. The signals coming from the voltage and current measuring equipment are limited by a group of diodes, then amplified-separated, and the resulting signals are connected to the input of a XOR TTL logic gate. The signal from the XOR TTL gate output has constant amplitude pulses and time durations proportional to the phase-shift value between current and voltage. The signal after the XOR TTL gate is applied to the digital input of a microcontroller development board that, also, has an LCD shield. The program used to calculate the power factor according to the pulse length (proportional with phase-shift value) is presented. Experiments are performed with RL consumers to measure the power factor and the obtained measurements are compared with those measured with a precision device (power quality analyser).


  • Open Access

    Considerations on Current and Voltage Unbalance of Nonlinear Loads in Residential and Educational Sectors

    by Gabriel Nicolae Popa, Angela Iagăr, Corina Maria Diniș

    Most often, electrical consumers in the residential and educational sectors are different from industrial electrical consumers. Whereas the vast majority of industrial electrical consumers are low-voltage, three-phase (with three or four wires), electrical consumers in the residential and educational sectors are low-voltage, single-phase. However, in practice, electrical consumers in the residential and educational sectors are in large numbers. Usually, current and voltage unbalances are lower in the industrial sector compared to the residential and educational sectors, where there are a large number of low-voltage, single-phase consumers that are connected/disconnected in an uncontrollable way and that need to be wired and balanced on each phase of power transformers from power substations. The purpose of this paper is to present the results of electrical balance and improve the power factor in the power substation from residential and educational sectors. The paper investigates the current and voltage unbalance of nonlinear con sumers in the residential and educational sectors. For this purpose, we performed measurements in the laboratory and the power substation to investigate the unbalance in the three-phase system. Laboratory measurements were made in the unbalanced operation of the single-phase electrical consumers connected at three-phase system. The measurements from power substation were carried out after the electrical consumers were uniformly spread among the three phases from the low-voltage power network, on two different days: a workday and a weekend day. The current and apparent power unbalance were reduced and the power factor was improved using the capacitive single-phase electric consumers (e.g., personal computers, which are in large numbers in such sectors) evenly across the phases.


  • Open Access

    An analyse on analogue ESR-meter

    by C M Diniş, G N Popa, C D Cunţan, A Iagăr

    The paper presents an analogue ESR meter, made with a JFET integrated circuit, which can be used to identify defective electrolytic capacitors. It is powered by continuous voltage and consists of a differential voltage source, a 100 kHz oscillator, a Wheatstone bridge with resistors supplied with alternating voltage, in a connecting arm of bridge being connected the electrolytic capacitors to be checked, a voltage amplifier-comparator with optical warning, a high-pass filter and a voltage-current converter. At the output of voltage-current converter is a milliammeter pointing out the ESR value (up to 20 Ω). Measurements were made on a batch of electrolytic capacitors (new and used) and a comparative analysis was performed between the measured values with an analogue ESR-meter and a digital one.