JLJames Langston

James Langston

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


James Langston has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Practical Estimation of Accuracy in Power Hardware-in-the-Loop Simulation Using Impedance Measurements

    by James Langston, Thiago Szymanski, Karl Schoder, Michael Mischa Steurer, Rodney G. Roberts

    Power hardware-in-the-loop (PHIL) simulation is a technique whereby actual power hardware is interfaced to a virtual surrounding system, simulated in real-time, through PHIL interfaces making use of power amplifiers and/or actuators. While PHIL simulation affords many advantages for flexible testing of power hardware, the accuracy of the experiment can be degraded through the non-ideal aspects of the PHIL interface, including distortion in the frequency domain, delays, and disturbances. This paper presents a practical method to estimate a subset of the closed-loop transfer function accuracy metrics of a PHIL experiment based on impedance measurements from the experiment. The method of assessing the impacts of the PHIL interfaces is demonstrated through application to an experiment in which two simulated systems are coupled through two PHIL interfaces with high bandwidth power amplifiers, enabling comparison of results with those from the ideal system.


  • Distributed energy storage allocation algorithm for early stage design

    by James Langston, Mark Stanovich, Karl Schoder, Michael Steurer

    This paper presents a novel algorithm for representing the effects of an optimal energy scheduling system in early stage analyses of systems employing distributed energy storage. The algorithm was developed in the context of a framework for analysis of systems employing energy storage, which includes such considerations as: system topology; load buffering, leveling, and shedding; uncertainty; size, weight, and cost. The presented algorithm provides a means for computing an optimal schedule of energy resource allocation for power- and energy-constrained scenarios. Of particular interest, the algorithm considers the possibility to withhold available stored energy from lower priority loads in order to serve higher priority loads at a later time (in a given scenario). By contrast, other works have generally assumed that energy is allocated immediately when a power deficit would otherwise require load to be shed.


  • Testing of a novel medium voltage impedance measurement unit

    by Karl Schoder, Mischa Steurer, Ferene Bogdan, John Hauer, James Langston, Dushan Boroyevich, Rolando Burgos, Igor Cvetkovic, Zhiyu Shen, Christina DiMarino

    In recent years the interest in deriving new concepts for electric distribution systems that build on power electronics converter interfaces for system components has increased rapidly. This interest is based on the promise that the power electronics based interfaces between distribution and generation/loads bring about higher efficiency, compacter implementation, and improved controllability. Nevertheless, ensuring stability of these converter dominated systems is a challenge. One means of analyzing stability properties is through measuring impedances, i.e., measuring input and output impedances of connected components. This paper presents results of testing the first available medium voltage impedance measurement unit.


  • System studies for a bi-directional advanced hybrid drive system (AHDS) for application on a future surface combatant

    by James Langston, Michael Andrus, Michael Steurer, Dwight Alexander, Jeffrey Buck, George Robinson, Don Wieczenski

    A project is currently underway to develop a bi-directional advanced hybrid drive system (AHDS) for application to a future surface combatant. This system would support propulsion powered through ship service gas turbine generators, as well as ship service power supplied from the mechanical propulsion gas turbines. This paper discusses system studies currently being conducted to assess the requirements and implications of incorporation of two such AHDS units on a future surface combatant.


  • Performance of 2G HTS Tapes in Sub-Cooled LN2 for Superconducting Fault Current Limiting Applications

    by J. C. Llambes, D. Hazelton, J. Duval, M. Albertini, S. Repnoy, V. Selvamanickam, G. Majkic, I. Kesign, J. Langston, M. Steurer, et al.

    Within the past few years a newer, more robust type of superconductor known as 2nd Generation High Temperature Superconductor (HTS) wire, has become available in sufficient quantity and lengths for developers to build prototype devices and test their capabilities. This new material offers the potential for revolutionary changes in superconducting transformers and Super conducting Fault Current Limiters to enable better thermal stability and fast quenching capabilities that can meet the stringent demands of large transient faults for distribution and transmission power lines. This manuscript discusses the manufacturing and latest tests and capabilities of sub-cooled superconducting fault current limiter device and modules designed for distribution and trans mission lines. We will also discuss the advantages and superior performance of the new 2nd Generation HTS superconductors under sub-cooled liquid nitrogen operation when used in super conducting fault current limiters. The feasibility demonstration and performance of sub-cooled SFCL superconducting modules for distribution and transmission SFCL devices will be discussed.


  • Open Access

    Hardware-in-the-Loop Testing of a High-Speed Generator Excitation Controller

    by K. Schoder, J. Langston, M. Steurer, S. Azongha, M. Sloderbeck, T. Chiocchio, C. Edrington, A. Farrell, J. Vaidya, K. Yost

    Electrodynamics Associates (EA) is developing a MW-class high-speed generator and requires testing of the corresponding excitation controller at Florida State University's (FSU) Center for Advanced Power Systems (CAPS) in a controller hardware-in-the-loop (CHIL) environment. The goal of these tests is to verify the functionality of the generator excitation controller prior to a full scale power hardware-in- the-loop (PHIL) test of the entire generator. Such tests will become feasible at FSU-CAPS in spring of 2010 as the center is currently procuring a gear system that will extend the shaft speed range of the existing 5 MW PHIL facility for rotating machinery from 450 rpm up to 24,000 rpm. This paper focuses on the CHIL testing of the primary excitation system controller, in which the secondary excitation power supply, the main generator, the prime mover, and the load were simulated on a real time computer simulator and interfaced to the controller. Simulating the high-speed generator in real-time is especially challenging since non real-time simulation models of such rotating machines typically contain relatively small time constants which pose challenges to real-time simulation algorithms. The paper discusses approaches to overcome these challenges. In addition, the plans and considerations for PHIL testing of the generator are addressed. This setup will enable, for the first time in a laboratory setup, PHIL testing of a MW scale high-speed generator with a realistic representation of its surrounding dynamic environment.

  • Power Hardware-in-the-Loop Testing of a YBCO Coated Conductor Fault Current Limiting Module

    by Christian Schacherer, James Langston, Michael Steurer, Mathias Noe

    In recent years, good progress has been made in improving the quality and quantity afforded by the manufacturing process for YBCO coated conductors. As a result, several programs have started to develop electrical power applications like motors, transformers, and fault current limiters (SCFCL) with these conductors. High voltage resistive type SCFCLs may typically be assembled from modules connected in series and parallel to accommodate the required voltage and current levels. The limited length of such a SCFCL module simplifies the configuration, manufacturing, and maintenance. It also allows testing of these modules under laboratory conditions at reduced power levels. In order to test SCFCL modules under conditions they will experience in high voltage electrical networks, advanced test methods such as power hardware-in-the-loop (PHIL) can offer significant advantages. This method allows studying conditions such as voltage stability and severe system perturbations with the actual SCFCL module in the loop. Hence, the quench and recovery behavior of the SCFCL module can be investigated under conditions characteristic of real electrical power networks without elaborate experimental setups. This paper presents results from PHIL experiments with a SCFCL module consisting of an approx. 10 m coated conductor.


  • Considerations in Simulation of a Notional All-Electric Ship AC/DC Conversion System

    by J. Langston, A. Martin, S. Suryanarayanan, M. Steurer, M. Andrus, S. L. Woodruff, J. Simpson

    In order to characterize and understand the behavior of a simulation model of the AC/DC conversion system of a notional all-electric ship system, experimental design methodology is applied in the construction of surrogate models. Confidence in the fidelity of the simulation is assessed through sensitivity and uncertainty analyses applied to the surrogate models.

  • Voltage Sensitivity to Capacitor Switching on an Existing Fixed Speed Induction Generator Wind Farm

    by M. Steurer, J. Langston, L. Anderson, S. Suryanarayanan, R. Meeker, P. Ribeiro

    Switched capacitors at wind farms employing fixed speed induction generators are intended to provide reactive power support to control and maintain the voltage at the point of common coupling (PCC) within acceptable operational values. Malfunction of the capacitor switching control may lead to voltage depression and, subsequently, to tripping of turbines which could create additional transient power quality disturbances. This paper presents results of simulations of voltage regulation problems of an existing wind farm on the Bonneville power administration (BPA) system where voltage regulation problems have led to the study of possible dynamic voltage compensation schemes to minimize the problem. SCADA data for real and reactive powers and voltage have been analyzed against results from simulation models to verify the behavior and confirm the mechanisms associated with the voltage regulation problems. Other aspects associated with the high fidelity modeling of the wind farm and issues about the sizing of a possible dynamic voltage controller are investigated.


  • Investigating the Impact of Pulsed Power Charging Demands on Shipboard Power Quality

    by M. Steurer, M. Andrus, J. Langston, L. Qi, S. Suryanarayanan, S. Woodruff, P.F. Ribeiro

    The impact of pulsed power loads on shipboard power systems need to be properly determined to prevent pulsed loads from causing unacceptable power quality deviations, interference with other loads and degradation of overall system performance. This paper uses a high fidelity modeling and simulation approach to investigate the impact of real and reactive power, pulse ramp rate, pulse duration and frequency of occurrence of the pulsed power load. For this purpose, a notional shipboard power system, modeled in a real-time digital simulator, is used. Most pulsed loads on shipboard systems are not fed directly from the prime power system but via an energy storage system. This energy storage system in turn is interfaced with the shipboard prime power system typically through an electronic front-end charging circuit. In order to evaluate the impact of pulsed loads, existing power quality standards (related to voltage transients, harmonic distortions, and frequency variations) are applied.