Zhiqi Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhiqi Huang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Dongyi Chen
2 shared publicationsHoujun Wang
2 shared publications- Chunting Wan
School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
1 shared publication - Dongyi Chen
School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
1 shared publication Feng Guo
School of Information Engineering, Southwest University of Science and Technology, Mianyang, China
1 shared publication- Feng Guo
School of Information Engineering, Southwest University of Science and Technology, Mianyang, China
1 shared publication
Latest Publications
- Open Access
A Wearable Head Mounted Display Bio-Signals Pad System for Emotion Recognition
Multimodal bio-signals acquisition based on wearable devices and using virtual reality (VR) as stimulus source are promising techniques in emotion recognition research field. Numerous studies have shown that emotional states can be better evoked through Immersive Virtual Environments (IVE). The main goal of this paper is to provide researchers with a system for emotion recognition in VR environments. In this paper, we present a wearable forehead bio-signals acquisition pad which is attached to Head-Mounted Displays (HMD), termed HMD Bio Pad. This system can simultaneously record emotion-related two-channel electroencephalography (EEG), one-channel electrodermal activity (EDA), photoplethysmograph (PPG) and skin temperature (SKT) signals. In addition, we develop a human-computer interaction (HCI) interface which researchers can carry out emotion recognition research using VR HMD as stimulus presentation device. To evaluate the performance of the proposed system, we conducted different experiments to validate the multimodal bio-signals quality, respectively. To validate EEG signal, we have assessed the performance in terms of EEG eyes-blink task and eyes-open and eyes-closed task. The EEG eyes-blink task indicates that the proposed system can achieve comparable EEG signal quality in comparison to the dedicated bio-signals measuring device. The eyes-open and eyes-closed task proves that the proposed system can efficiently record alpha rhythm. Then we used signal-to-noise ratio (SNR) and Skin Conductance Reaction (SCR) signal to validate the performance for EDA acquisition system. A filtered EDA signal, with a high mean SNR of 28.52 dB, is plotted on HCI interface. Moreover, the SCR signal related to stimulus response can be correctly extracted from EDA signal. The SKT acquisition system has been validated effectively by the temperature change experiment when subjects are in unpleasant emotion. The pulse rate (PR) estimated from PPG signal achieved the low mean average absolute error (AAE), which is 1.12 beats per minute (BPM) over 8 recordings. In summary, the proposed HMD Bio Pad offers a portable, comfortable and easy-to-wear device for recording bio-signals. The proposed system could contribute to emotion recognition research in VR environments.
Open AccessA Wearable Head Mounted Display Bio-Signals Pad System for Emotion Recognition
Multimodal bio-signals acquisition based on wearable devices and using virtual reality (VR) as stimulus source are promising techniques in emotion recognition research field. Numerous studies have shown that emotional states can be better evoked through Immersive Virtual Environments (IVE). The main goal of this paper is to provide researchers with a system for emotion recognition in VR environments. In this paper, we present a wearable forehead bio-signals acquisition pad which is attached to Head-Mounted Displays (HMD), termed HMD Bio Pad. This system can simultaneously record emotion-related two-channel electroencephalography (EEG), one-channel electrodermal activity (EDA), photoplethysmograph (PPG) and skin temperature (SKT) signals. In addition, we develop a human-computer interaction (HCI) interface which researchers can carry out emotion recognition research using VR HMD as stimulus presentation device. To evaluate the performance of the proposed system, we conducted different experiments to validate the multimodal bio-signals quality, respectively. To validate EEG signal, we have assessed the performance in terms of EEG eyes-blink task and eyes-open and eyes-closed task. The EEG eyes-blink task indicates that the proposed system can achieve comparable EEG signal quality in comparison to the dedicated bio-signals measuring device. The eyes-open and eyes-closed task proves that the proposed system can efficiently record alpha rhythm. Then we used signal-to-noise ratio (SNR) and Skin Conductance Reaction (SCR) signal to validate the performance for EDA acquisition system. A filtered EDA signal, with a high mean SNR of 28.52 dB, is plotted on HCI interface. Moreover, the SCR signal related to stimulus response can be correctly extracted from EDA signal. The SKT acquisition system has been validated effectively by the temperature change experiment when subjects are in unpleasant emotion. The pulse rate (PR) estimated from PPG signal achieved the low mean average absolute error (AAE), which is 1.12 beats per minute (BPM) over 8 recordings. In summary, the proposed HMD Bio Pad offers a portable, comfortable and easy-to-wear device for recording bio-signals. The proposed system could contribute to emotion recognition research in VR environments.
- 1 December 2012
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 61 (12) , 1932-1937
Stochastic resonance in the logistic growth model with time-modulated correlated noise
Stochastic resonance in the logistic model driven by time-modulated correlated multiplicative and additive noises is investigated. For small amounts of the two noises, a small amplitude of the additive modulated signal and a small intensity of the time-modulated correlated noise, under the adiabatic approximation, the analysis expressions of the signal-to-noise ratios for different frequencies and equal frequencies of the two modulation forces have been obtained. Theoretical and numerical study shows that the signal-to-noise ratios vary non-monotonically with increasing intensities of the multiplicative and additive noises. The curves of the signal-to-noise ratio versus additive noise strength present two peaks while one peak exists in each of the curves for the signal-to-noise ratio as a function of the multiplicative noise intensity. In addition, for equal frequency of the two modulation forces, the signal-to-noise ratio behaves non-monotonically with increasing amplitude of the time-modulation force.
- 1 December 2012
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 61 (12) , 1932-1937
Stochastic resonance in the logistic growth model with time-modulated correlated noise
Stochastic resonance in the logistic model driven by time-modulated correlated multiplicative and additive noises is investigated. For small amounts of the two noises, a small amplitude of the additive modulated signal and a small intensity of the time-modulated correlated noise, under the adiabatic approximation, the analysis expressions of the signal-to-noise ratios for different frequencies and equal frequencies of the two modulation forces have been obtained. Theoretical and numerical study shows that the signal-to-noise ratios vary non-monotonically with increasing intensities of the multiplicative and additive noises. The curves of the signal-to-noise ratio versus additive noise strength present two peaks while one peak exists in each of the curves for the signal-to-noise ratio as a function of the multiplicative noise intensity. In addition, for equal frequency of the two modulation forces, the signal-to-noise ratio behaves non-monotonically with increasing amplitude of the time-modulation force.
- 10 December 2009
- Published by China Science Publishing & Media Ltd. in JOURNAL OF ELECTRONIC MEASUREMENT AND INSTRUMENT
- Vol. 2009 (10) , 31-36
The study on the vibration optimization model of the wearable computer motherboard
- 10 December 2009
- Published by China Science Publishing & Media Ltd. in JOURNAL OF ELECTRONIC MEASUREMENT AND INSTRUMENT
- Vol. 2009 (10) , 31-36
The study on the vibration optimization model of the wearable computer motherboard
- 9 December 2009
- Published by China Science Publishing & Media Ltd. in JOURNAL OF ELECTRONIC MEASUREMENT AND INSTRUMENT
- Vol. 2009 (11) , 11-18
Study on wearable decision-making model of the wearable computer
- 9 December 2009
- Published by China Science Publishing & Media Ltd. in JOURNAL OF ELECTRONIC MEASUREMENT AND INSTRUMENT
- Vol. 2009 (11) , 11-18
Study on wearable decision-making model of the wearable computer