Maria T. Penella
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maria T. Penella has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Manel Gasulla
Department of Electronic Engineering, Universitat Politcnica de CatalunyaBarcelonaTech, Castelldefels, Barcelona, Spain
3 shared publications
Latest Publications
- 18 February 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 59 (4) , 857-865
Runtime Extension of Low-Power Wireless Sensor Nodes Using Hybrid-Storage Units
The sensor nodes of wireless sensor networks remain inactive most of the time to achieve longer runtimes. Power is mainly provided by batteries, which are either primary or secondary. Because of its internal impedance, a significant voltage drop can appear across the battery terminals at the activation time of the node, thus preventing the extraction of all the energy from the battery. Additionally, internal losses can also be significant. Consequently, the runtime is reduced. The addition of a supercapacitor in parallel with the battery, thus forming a hybrid-storage device, has been proposed under pulsed loads to increase the power capabilities and reduce both the voltage drop and the internal losses at the battery. However, this strategy has not yet thoroughly been analyzed and tested in low-power wireless sensor nodes. This paper presents a comprehensive theoretical analysis that extends previous works found in the literature and provides design guidelines for choosing the appropriate supercapacitor. The analysis is supported by extensive experimental results. Two low-capacity (< 200 mAh) batteries were tested together with their hybrid-storage unit counterparts when using an electronic load as a pulsed current sink. The hybrid-storage units always achieved a higher runtime. One of the batteries was also tested using a sensor node. The runtime extension was 16% and 33% when connecting the hybrid-storage unit directly and through a dc-dc switching regulator to the sensor node, respectively.
- 18 February 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 59 (4) , 857-865
Runtime Extension of Low-Power Wireless Sensor Nodes Using Hybrid-Storage Units
The sensor nodes of wireless sensor networks remain inactive most of the time to achieve longer runtimes. Power is mainly provided by batteries, which are either primary or secondary. Because of its internal impedance, a significant voltage drop can appear across the battery terminals at the activation time of the node, thus preventing the extraction of all the energy from the battery. Additionally, internal losses can also be significant. Consequently, the runtime is reduced. The addition of a supercapacitor in parallel with the battery, thus forming a hybrid-storage device, has been proposed under pulsed loads to increase the power capabilities and reduce both the voltage drop and the internal losses at the battery. However, this strategy has not yet thoroughly been analyzed and tested in low-power wireless sensor nodes. This paper presents a comprehensive theoretical analysis that extends previous works found in the literature and provides design guidelines for choosing the appropriate supercapacitor. The analysis is supported by extensive experimental results. Two low-capacity (< 200 mAh) batteries were tested together with their hybrid-storage unit counterparts when using an electronic load as a pulsed current sink. The hybrid-storage units always achieved a higher runtime. One of the batteries was also tested using a sensor node. The runtime extension was 16% and 33% when connecting the hybrid-storage unit directly and through a dc-dc switching regulator to the sensor node, respectively.
- 1 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1184-1188
Battery Squeezing under Low-Power Pulsed Loads
Autonomous sensors are wireless measurement systems that in order to achieve longer runtimes remain inactive most of the time and wake up only to acquire and send data. As a result, autonomous sensors can be modeled as low-power pulsed loads. Power is provided by batteries, either primary or secondary. Whenever the autonomous sensor wakes up, a significant voltage drop can appear between the battery terminals, thus preventing to squeeze all the available energy from the battery and leading to a reduction of the load runtime. This work proposes the use of hybrid-storage units, formed by the parallel combination of a battery and a (super)capacitor, in order to extend the runtime of low-power pulsed loads. We show analytical expressions of the transient voltage drop at the terminals of the hybrid-storage unit and deduce the minimal value of the capacitor to be used for a given voltage drop. Experimental results support the theoretical analysis. We tested several combinations of batteries and capacitors as the hybrid-storage unit under pulsed loads of tens of milliamps. Finally, we assessed the performance of the hybrid-storage unit when using as a load a commercial transceiver intended for wireless sensor networks applications.
- 1 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1184-1188
Battery Squeezing under Low-Power Pulsed Loads
Autonomous sensors are wireless measurement systems that in order to achieve longer runtimes remain inactive most of the time and wake up only to acquire and send data. As a result, autonomous sensors can be modeled as low-power pulsed loads. Power is provided by batteries, either primary or secondary. Whenever the autonomous sensor wakes up, a significant voltage drop can appear between the battery terminals, thus preventing to squeeze all the available energy from the battery and leading to a reduction of the load runtime. This work proposes the use of hybrid-storage units, formed by the parallel combination of a battery and a (super)capacitor, in order to extend the runtime of low-power pulsed loads. We show analytical expressions of the transient voltage drop at the terminals of the hybrid-storage unit and deduce the minimal value of the capacitor to be used for a given voltage drop. Experimental results support the theoretical analysis. We tested several combinations of batteries and capacitors as the hybrid-storage unit under pulsed loads of tens of milliamps. Finally, we assessed the performance of the hybrid-storage unit when using as a load a commercial transceiver intended for wireless sensor networks applications.
- Open Access
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-5
A Review of Commercial Energy Harvesters for Autonomous Sensors
Current commercial autonomous sensors are mainly powered by primary batteries. Batteries need to be replaced and hence can become the largest and most expensive part of the system. On the other hand, our environment is full of waste and unused energy such as that coming from the sun or mechanical vibrations. As a result, commercial energy harvesters are increasingly available to power autonomous sensors. This work presents and analyses commercial energy harvesters currently available. First, environmental energy sources are classified and described. Then, energy harvesting principles are described and some guidelines are given to calculate the maximum power consumption allowed and the energy storage capacity required for the autonomous sensor. Finally, commercial energy harvesters are evaluated to determine their capability to power a commercial autonomous sensor in some given circumstances.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-5
Open AccessA Review of Commercial Energy Harvesters for Autonomous Sensors
Current commercial autonomous sensors are mainly powered by primary batteries. Batteries need to be replaced and hence can become the largest and most expensive part of the system. On the other hand, our environment is full of waste and unused energy such as that coming from the sun or mechanical vibrations. As a result, commercial energy harvesters are increasingly available to power autonomous sensors. This work presents and analyses commercial energy harvesters currently available. First, environmental energy sources are classified and described. Then, energy harvesting principles are described and some guidelines are given to calculate the maximum power consumption allowed and the energy storage capacity required for the autonomous sensor. Finally, commercial energy harvesters are evaluated to determine their capability to power a commercial autonomous sensor in some given circumstances.