Ronalee Lo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ronalee Lo has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Ellis Meng
Department of Biomedical Engineering, University of Southern California, Los Angeles, USA
2 shared publications- Ellis Meng
University of Southern California
2 shared publications Kenrick Kuwahara
University of Southern California, Viterbi School of Engineering, 1042 Downey Way, DRB-140, Los Angeles, CA 90089-1111, USA
1 shared publicationMark S. Humayun
University of Southern California, Department of Ophthalmology, 1042 Downey Way, DRB-140, Los Angeles, CA 90089-1111, USA
1 shared publicationPo-Ying Li
University of Southern California, Viterbi School of Engineering, 1042 Downey Way, DRB-140, Los Angeles, CA 90089-1111, USA
1 shared publicationRajat Agrawal
University of Southern California, Department of Ophthalmology, 1042 Downey Way, DRB-140, Los Angeles, CA 90089-1111, USA
1 shared publication
Latest Publications
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 20 (5) , 1163-1173
A Modular Heat-Shrink-Packaged Check Valve With High Pressure Shutoff
A novel check valve featuring adhesiveless packaging in heat-shrink tubing and dual regulation of in-plane flow is presented. The modular design enables simple replacement of valve components to modify valve behavior and performance. The specific design is intended for low-profile fluidic applications requiring flow control, such as drug delivery devices. The heat-shrink packaging scheme is extremely robust and can withstand >; 2000 mmHg (266.6 kPa) without leakage. Three different valve geometries were investigated and evaluated with theoretical and finite-element modeling analyses. Repeated flow regulation experiments on a fully packaged, hydrated valve demonstrated flow regulation between 25 and 2000 mmHg (3.33-266.6 kPa) and leak-free closure up to 500 mmHg (66.7 kPa) of reverse pressure with no observed stiction. The valve closing time constants were also determined.
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 20 (5) , 1163-1173
A Modular Heat-Shrink-Packaged Check Valve With High Pressure Shutoff
A novel check valve featuring adhesiveless packaging in heat-shrink tubing and dual regulation of in-plane flow is presented. The modular design enables simple replacement of valve components to modify valve behavior and performance. The specific design is intended for low-profile fluidic applications requiring flow control, such as drug delivery devices. The heat-shrink packaging scheme is extremely robust and can withstand >; 2000 mmHg (266.6 kPa) without leakage. Three different valve geometries were investigated and evaluated with theoretical and finite-element modeling analyses. Repeated flow regulation experiments on a fully packaged, hydrated valve demonstrated flow regulation between 25 and 2000 mmHg (3.33-266.6 kPa) and leak-free closure up to 500 mmHg (66.7 kPa) of reverse pressure with no observed stiction. The valve closing time constants were also determined.
- 16 June 2008
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 132 (2) , 531-539
Integrated and reusable in-plane microfluidic interconnects
- 16 June 2008
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 132 (2) , 531-539
Integrated and reusable in-plane microfluidic interconnects
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2067-2070
A Reusable In-Plane Polymer Integrated Microfluidic Interconnect
A novel reusable, in-plane polymer interconnect directly integrated into a microfluidic system is demonstrated. This approach features plug-and-play style connections to microfluidic networks in which commercially available non-coring syringe needles are simply inserted through pre-defined polydimethylsiloxane (PDMS) septums to form rapid, on-demand connections to microchannels. These septums are mechanically anchored by one layer of SU-8 that also forms the microchannels. Interconnect design, fabrication, theoretical analysis, and experimental results (pull-out force and leakage) are presented.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2067-2070
A Reusable In-Plane Polymer Integrated Microfluidic Interconnect
A novel reusable, in-plane polymer interconnect directly integrated into a microfluidic system is demonstrated. This approach features plug-and-play style connections to microfluidic networks in which commercially available non-coring syringe needles are simply inserted through pre-defined polydimethylsiloxane (PDMS) septums to form rapid, on-demand connections to microchannels. These septums are mechanically anchored by one layer of SU-8 that also forms the microchannels. Interconnect design, fabrication, theoretical analysis, and experimental results (pull-out force and leakage) are presented.
- 1 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 74-77
A Passive Refillable Intraocular MEMS Drug Delivery Device
This paper presents the first passive implantable microelectromechanical systems (MEMS) device for targeted intraocular delivery of therapeutic compounds. In particular, this device addresses the treatment of chronic, difficult to reach diseases that affect the retina including retinitis pigmentosa, age-related macular degeneration, diabetic retinopathy, and glaucoma. The device is composed of three structural polymethyldisiloxane (PDMS) layers that are irreversibly bonded without the use of any adhesives. These layers form an integrated drug delivery device consisting of a refillable reservoir, tube, check valve, and suture tabs. This device requires a single implantation surgery and is capable of repeated delivery of multiple drugs. Characterization of the refillable reservoir and check valve performance is presented. Preliminary surgical implantation results of a mechanical test structure are also presented
- 1 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 74-77
A Passive Refillable Intraocular MEMS Drug Delivery Device
This paper presents the first passive implantable microelectromechanical systems (MEMS) device for targeted intraocular delivery of therapeutic compounds. In particular, this device addresses the treatment of chronic, difficult to reach diseases that affect the retina including retinitis pigmentosa, age-related macular degeneration, diabetic retinopathy, and glaucoma. The device is composed of three structural polymethyldisiloxane (PDMS) layers that are irreversibly bonded without the use of any adhesives. These layers form an integrated drug delivery device consisting of a refillable reservoir, tube, check valve, and suture tabs. This device requires a single implantation surgery and is capable of repeated delivery of multiple drugs. Characterization of the refillable reservoir and check valve performance is presented. Preliminary surgical implantation results of a mechanical test structure are also presented