Viktor Bolgov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Viktor Bolgov has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dmitry Kalyuzhniy
O.M. Beketov National University of Urban Economy in Kharkiv
2 shared publications - Yuriy Sayenko
Institute of Electrical Power Engineering, Lodz University of Technology, 20 Stefanowskiego Street, 90-537 Lodz, Poland
2 shared publications Jaan Jarvik
Tallinn University of Technology/Department of Electric Machines and Fundamentals of Electrical Engineering/, Tallinn, Estonia
1 shared publication- Jaan Jarvik
Department of Electric Machines and Fundamentals of Electrical Engineering, TUT, Tallinn, 19086 Estonia. phone: 372-620-3800; fax: 372-620-3800
1 shared publication - Kuno Janson
Department of Electric Machines and Fundamentals of Electrical Engineering, Tallinn University of Technology (TUT), Tallinn, 19086 Estonia
1 shared publication - Maria Sukhonos
O.M. Beketov National University of Urban Economy in Kharkiv
1 shared publication
Latest Publications
- 25 October 2019
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2019 (6) , 65-73
IDENTIFICATION AND ASSESSMENT OF THE INFLUENCE OF UNBALANCE VOLTAGE SOURCES IN THREE-PHASE THREE-WIRE ELECTRIC NETWORKS
Joomla! - the dynamic portal engine and content management system
- 25 October 2019
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2019 (6) , 65-73
IDENTIFICATION AND ASSESSMENT OF THE INFLUENCE OF UNBALANCE VOLTAGE SOURCES IN THREE-PHASE THREE-WIRE ELECTRIC NETWORKS
Joomla! - the dynamic portal engine and content management system
- 31 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 55, 29-35
Mathematical model for real-time assessment of contributions of disturbing sources to power quality level at a Point of Common Coupling
The presented paper describes the generalized mathematical model for the real-time assessment of contributions of disturbing sources (DSs) to voltage unbalance and slow voltage variation at a Point of Common Coupling (PCC). This model is intended to be the basis for a distributed and time-synchronized PQ measuring system. The model was developed on the basis of the node voltage method by using phasors of actual state parameter. DSs are assumed to be randomly distributed throughout the considering network. The simulation verification has demonstrated adequate results.
- 31 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 55, 29-35
Mathematical model for real-time assessment of contributions of disturbing sources to power quality level at a Point of Common Coupling
The presented paper describes the generalized mathematical model for the real-time assessment of contributions of disturbing sources (DSs) to voltage unbalance and slow voltage variation at a Point of Common Coupling (PCC). This model is intended to be the basis for a distributed and time-synchronized PQ measuring system. The model was developed on the basis of the node voltage method by using phasors of actual state parameter. DSs are assumed to be randomly distributed throughout the considering network. The simulation verification has demonstrated adequate results.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21669538,p. 1-7
Current Stabilization for Improving Electromagnetic Compatibility of Highly Varying Loads by Use of Saturable Reactor
Power quality control in the case of powerful abruptly variable loads, e.g. electric arc furnaces, becomes an actual problem due to the deregulation of electricity markets. A way to mitigate distortions on a power supply network, especially the flicker, is load current stabilization. The saturable reactor is proposed as a solution.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21669538,p. 1-7
Current Stabilization for Improving Electromagnetic Compatibility of Highly Varying Loads by Use of Saturable Reactor
Power quality control in the case of powerful abruptly variable loads, e.g. electric arc furnaces, becomes an actual problem due to the deregulation of electricity markets. A way to mitigate distortions on a power supply network, especially the flicker, is load current stabilization. The saturable reactor is proposed as a solution.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
New theoretical approach to input current shaping in ac-dc power converters
A new method for an input current waveform correction in typical power converters is described. It assumes an implementation of the so-called virtual transformer with a fast-changing voltage ratio. Theory and calculations are presented to confirm the method validity. Practical implementation is left out of the scope of the given paper due to size limitations.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
New theoretical approach to input current shaping in ac-dc power converters
A new method for an input current waveform correction in typical power converters is described. It assumes an implementation of the so-called virtual transformer with a fast-changing voltage ratio. Theory and calculations are presented to confirm the method validity. Practical implementation is left out of the scope of the given paper due to size limitations.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1417-1422
Suppression of Voltage Flicker by Saturable Reactor Operating under Forced Magnetization
Power quality control in the case of powerful abruptly variable loads, e.g. electric arc furnaces, becomes an actual problem due to the deregulation of electricity markets. A way to mitigate distortions on a power supply network, especially the flicker, is load current stabilization. The saturable reactor is proposed as a solution.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1417-1422
Suppression of Voltage Flicker by Saturable Reactor Operating under Forced Magnetization
Power quality control in the case of powerful abruptly variable loads, e.g. electric arc furnaces, becomes an actual problem due to the deregulation of electricity markets. A way to mitigate distortions on a power supply network, especially the flicker, is load current stabilization. The saturable reactor is proposed as a solution.