G. Cavone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
G. Cavone has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- A. M. L. Lanzolla
DIASS, Polytechnic of Bari, viale del Turismo, 8, 74100 Taranto, ITALY
2 shared publications - Attilio Di Nisio
Department of Electrical and Information Engineering, Polytechnic University of Bari, Via E. Orabona 4, 70125 Bari, Italy
2 shared publications - Filippo Attivissimo
Department of Electrical and Information Engineering, Polytechnic University of Bari, Via E. Orabona 4, 70125 Bari, Italy
2 shared publications - Laura Fabbiano
Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, via Orabona 4, 70125 Bari, Italy
2 shared publications - Mario Savino
Dept. of Electrical and Electronic Engineering, Polytechnic of Bari, via E. Orabona 4, 70125 Bari, Italy
2 shared publications - Francesco Adamo
Department of Electrical and Information Engineering, Polytechnic University of Bari, Bari, Italy
1 shared publication
Latest Publications
- 13 May 2009
- Published by Elsevier in Measurement
- Vol. 42 (8) , 1123-1130
Application of hand grip signals for an objective evaluation of Parkinson disease: Analysis and comparison with standard functional clinical tests
- 13 May 2009
- Published by Elsevier in Measurement
- Vol. 42 (8) , 1123-1130
Application of hand grip signals for an objective evaluation of Parkinson disease: Analysis and comparison with standard functional clinical tests
- 1 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1179-1183
Analysis and Optimization of the Acquisition Times in the Magnetic Resonance Imaging
The main purpose of this work is to analyze the magnetic resonance imaging (MRI) methodologies used in noninvasive clinical investigation, with the aim of reducing the time of acquisition by assuring a good quality of the images. This objective is of fundamental importance to both increase the number of clinical tests produced with this equipments and to reduce the radiation doses in the patients. For this purpose the parameters influencing the time acquisition and the signal-to-noise ratio (SNR) were investigated and a software platform to optimize the imaging time acquisition was developed. This work was carried out in collaboration with Martina Franca (Italy) Hospital. Tanks to the staff of this sanitary structure it has been possible to get the necessary material for the correct development of the simulation algorithm and the sample images on which the algorithm has been applied and verified.
- 1 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1179-1183
Analysis and Optimization of the Acquisition Times in the Magnetic Resonance Imaging
The main purpose of this work is to analyze the magnetic resonance imaging (MRI) methodologies used in noninvasive clinical investigation, with the aim of reducing the time of acquisition by assuring a good quality of the images. This objective is of fundamental importance to both increase the number of clinical tests produced with this equipments and to reduce the radiation doses in the patients. For this purpose the parameters influencing the time acquisition and the signal-to-noise ratio (SNR) were investigated and a software platform to optimize the imaging time acquisition was developed. This work was carried out in collaboration with Martina Franca (Italy) Hospital. Tanks to the staff of this sanitary structure it has been possible to get the necessary material for the correct development of the simulation algorithm and the sample images on which the algorithm has been applied and verified.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 110-112
Development of a System for Soil Microclimatic Analysis
In this paper the design and the development of a moisture sensor for granular and porous mediums are presented. In the proposed method the moisture is measured by estimating the velocity of propagation of seismic waves (both compressional and shear ones) between a transmitter and a receiver separated by a known distance. The first experimental results are illustrated and compared with theoretical results.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 110-112
Development of a System for Soil Microclimatic Analysis
In this paper the design and the development of a moisture sensor for granular and porous mediums are presented. In the proposed method the moisture is measured by estimating the velocity of propagation of seismic waves (both compressional and shear ones) between a transmitter and a receiver separated by a known distance. The first experimental results are illustrated and compared with theoretical results.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-5
Improved Static Testing of A/D Converters for DC Measurements
A new static test for DC digital instruments and analog-to-digital converters is presented. The test is truly static because it uses only DC voltages with a small superimposed noise. It is much faster than the one described in IEEE standard 1057/94, since it uses a minimal number of input signals and acquired samples in a theoretically nearly optimal manner (ML estimation). Besides, contrary to the test described in IEEE Standards 1241/00, it allows off-line measurements and testing of stand-alone instruments like digital multimeters. Both simulations and experimental results are provided to illustrate the performance of the proposed test method.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-5
Improved Static Testing of A/D Converters for DC Measurements
A new static test for DC digital instruments and analog-to-digital converters is presented. The test is truly static because it uses only DC voltages with a small superimposed noise. It is much faster than the one described in IEEE standard 1057/94, since it uses a minimal number of input signals and acquired samples in a theoretically nearly optimal manner (ML estimation). Besides, contrary to the test described in IEEE Standards 1241/00, it allows off-line measurements and testing of stand-alone instruments like digital multimeters. Both simulations and experimental results are provided to illustrate the performance of the proposed test method.