Pierre-André Vuissoz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pierre-André Vuissoz has a total of 119 co-authors. Here are the top co-authors by number of shared publications:
- Jacques Felblinger
IADI (U1254) Université de Lorraine and Inserm Nancy France
27 shared publications - Freddy Odille
IADI U1254, INSERM and Université de Lorraine Nancy France
15 shared publications Damien Mandry
CHRU de Nancy, CHRU Nancy Brabois, Nancy, 54035, FRANCE
10 shared publications- Karyna Isaieva
IADI U1254, Inserm, Université de Lorraine, Nancy, France
9 shared publications - Laurent Bonnemains
U947, INSERM, Nancy, France
6 shared publications Christophe Meyer
U947, INSERM, Nancy, France
5 shared publications
Latest Publications
- 24 February 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (4) , 1505-1516
Cardiac neural representations for ECG-guided slice-to-volume reconstruction
- 24 February 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (4) , 1505-1516
Cardiac neural representations for ECG-guided slice-to-volume reconstruction
- Open Access
- 1 January 2026
- Published by Wiley in Radiology Research and Practice
- Vol. 2026 (1) , 6214002
Biomechanical Assessment Using MRI of Custom‐Made Bovine Pericardial Tubes as Potential Aortic Replacements
Introduction: Autologous materials for vessel replacement in infected fields have high morbidity and mortality rates. Custom‐made bovine pericardial tubes (CMBPTs) offer a promising alternative with advantages such as reliability, strength, and availability. However, limited biomechanical data hinder predictions of in vivo performance. This study evaluates the physiological strain and distensibility of CMBPTs in vitro under simulated abdominal aortic flow using magnetic resonance imaging (MRI). A secondary objective is to compare strain and distensibility calculations using phase contrast (PC) and steady‐state free precession (SSFP) MRI sequences. Methods: Seven CMBPTs were tested under physiological aortic conditions with a pulsatile flow rate of 1650 mL/min using in vitro MRI. PC and SSFP sequences were employed, with PC estimating velocity and strain, while SSFP assessed strain separately. Image analysis was performed using QIR‐MR software. Results: Strain was measured using magnitude images. The mean maximum cross‐sectional areas were 419 ± 22.1 (PC) and 438.4 ± 24.3 mm 2 (SSFP), while minimum areas were 374.5 ± 21.1 and 397.6 ± 23.4 mm 2 , respectively. The mean strain percentages were 12.1% ± 3.60% (PC) and 10.3% ± 3.20% (SSFP), with distensibility values of 1.5 ± 0.5 × 10 −3 and 1.3 ± 0.4 × 10 −3 mmHg −1 , respectively. Conclusion: CMBPTs exhibit biomechanical properties similar to the abdominal aorta, suggesting potential for vascular applications. Both MRI sequences provided comparable results, supporting their reliability. Further research is needed to confirm long‐term performance.
- 1 January 2026
- Published by Wiley in Radiology Research and Practice
- Vol. 2026 (1) , 6214002
Open AccessBiomechanical Assessment Using MRI of Custom‐Made Bovine Pericardial Tubes as Potential Aortic Replacements
Introduction: Autologous materials for vessel replacement in infected fields have high morbidity and mortality rates. Custom‐made bovine pericardial tubes (CMBPTs) offer a promising alternative with advantages such as reliability, strength, and availability. However, limited biomechanical data hinder predictions of in vivo performance. This study evaluates the physiological strain and distensibility of CMBPTs in vitro under simulated abdominal aortic flow using magnetic resonance imaging (MRI). A secondary objective is to compare strain and distensibility calculations using phase contrast (PC) and steady‐state free precession (SSFP) MRI sequences. Methods: Seven CMBPTs were tested under physiological aortic conditions with a pulsatile flow rate of 1650 mL/min using in vitro MRI. PC and SSFP sequences were employed, with PC estimating velocity and strain, while SSFP assessed strain separately. Image analysis was performed using QIR‐MR software. Results: Strain was measured using magnitude images. The mean maximum cross‐sectional areas were 419 ± 22.1 (PC) and 438.4 ± 24.3 mm 2 (SSFP), while minimum areas were 374.5 ± 21.1 and 397.6 ± 23.4 mm 2 , respectively. The mean strain percentages were 12.1% ± 3.60% (PC) and 10.3% ± 3.20% (SSFP), with distensibility values of 1.5 ± 0.5 × 10 −3 and 1.3 ± 0.4 × 10 −3 mmHg −1 , respectively. Conclusion: CMBPTs exhibit biomechanical properties similar to the abdominal aorta, suggesting potential for vascular applications. Both MRI sequences provided comparable results, supporting their reliability. Further research is needed to confirm long‐term performance.
- Open Access
Reconstruction of the Complete Vocal Tract Contour Through Acoustic to Articulatory Inversion Using Real-Time MRI Data
Acoustic to articulatory inversion has often been limited to a small part of the vocal tract because the data are generally EMA (ElectroMagnetic Articulography) data requiring sensors to be glued to easily accessible articulators. The presented acoustic to articulation model focuses on the inversion of the entire vocal tract from the glottis, the complete tongue, the velum, to the lips. It relies on a realtime dynamic MRI database of more than 3 hours of speech. The data are the denoised speech signal and the automatically segmented articulator contours. Several bidirectional LSTM-based approaches have been used, either inverting each articulator individually or inverting all articulators simultaneously. To our knowledge, this is the first complete inversion of the vocal tract. The average RMSE precision on the test set is 1.65 mm to be compared with the pixel size which is 1.62 mm.
Open AccessReconstruction of the Complete Vocal Tract Contour Through Acoustic to Articulatory Inversion Using Real-Time MRI Data
Acoustic to articulatory inversion has often been limited to a small part of the vocal tract because the data are generally EMA (ElectroMagnetic Articulography) data requiring sensors to be glued to easily accessible articulators. The presented acoustic to articulation model focuses on the inversion of the entire vocal tract from the glottis, the complete tongue, the velum, to the lips. It relies on a realtime dynamic MRI database of more than 3 hours of speech. The data are the denoised speech signal and the automatically segmented articulator contours. Several bidirectional LSTM-based approaches have been used, either inverting each articulator individually or inverting all articulators simultaneously. To our knowledge, this is the first complete inversion of the vocal tract. The average RMSE precision on the test set is 1.65 mm to be compared with the pixel size which is 1.62 mm.
- 15 August 2025
- Published by IOP Publishing in Physiological Measurement
- Vol. 46 (9)
Sensor-free physiological guidance for free-breathing cardiac cine MRI using implicit neural representation CineJENSE reconstruction
Objective: The aim of this study was to explore free-breathing cardiac cine images reconstructed with sensor-free physiological signals estimates. Such signals were estimated using the noise variance of the radio frequency receiver coils. Reconstructions with reference signals acquired during MR scan were compared with the sensor-free reconstructions using an extended CineJENSE algorithm. Approach: Free-breathing untriggered MRI cine data from 27 patients and 22 healthy volunteers in various slice orientations were acquired simultaneously with physiological signals using external sensors (ECG and respiratory belts). Physiological signals were estimated using the noise variance of receiver coils and specific signal processing with source separation. CineJENSE reconstruction, based on implicit neural representations was adapted to free-breathing data. Correlation coefficient between both respiration signals and F1-score of the cardiac peak detections were computed for quantitative results. The reconstructed images were visually inspected to asses their quality and presence of motion artefacts and an automatic segmentation was performed and compared to the manual segmentation with DICE scores computation. Main results: An average correlation coefficient of 0.69 ± 0.22 and F1-score of 0.73 ± 0.23 for all subjects was found. Reconstructed images quality was close to that of the reconstructed images with reference signals, although slightly lower (2.51 ± 0.8 and 2.84 ± 0.7). Dice scores for LV was 0.86 ± 0.13 for reconstructed images with sensor-free estimations compared to 0.85 ± 0.12 with external sensors. Significance: This study demonstrated overall good quality images of free-breathing acquisitions using cardiac and respiration motion estimations based on the RF noise navigator.
- 15 August 2025
- Published by IOP Publishing in Physiological Measurement
- Vol. 46 (9)
Sensor-free physiological guidance for free-breathing cardiac cine MRI using implicit neural representation CineJENSE reconstruction
Objective: The aim of this study was to explore free-breathing cardiac cine images reconstructed with sensor-free physiological signals estimates. Such signals were estimated using the noise variance of the radio frequency receiver coils. Reconstructions with reference signals acquired during MR scan were compared with the sensor-free reconstructions using an extended CineJENSE algorithm. Approach: Free-breathing untriggered MRI cine data from 27 patients and 22 healthy volunteers in various slice orientations were acquired simultaneously with physiological signals using external sensors (ECG and respiratory belts). Physiological signals were estimated using the noise variance of receiver coils and specific signal processing with source separation. CineJENSE reconstruction, based on implicit neural representations was adapted to free-breathing data. Correlation coefficient between both respiration signals and F1-score of the cardiac peak detections were computed for quantitative results. The reconstructed images were visually inspected to asses their quality and presence of motion artefacts and an automatic segmentation was performed and compared to the manual segmentation with DICE scores computation. Main results: An average correlation coefficient of 0.69 ± 0.22 and F1-score of 0.73 ± 0.23 for all subjects was found. Reconstructed images quality was close to that of the reconstructed images with reference signals, although slightly lower (2.51 ± 0.8 and 2.84 ± 0.7). Dice scores for LV was 0.86 ± 0.13 for reconstructed images with sensor-free estimations compared to 0.85 ± 0.12 with external sensors. Significance: This study demonstrated overall good quality images of free-breathing acquisitions using cardiac and respiration motion estimations based on the RF noise navigator.
- Open Access
- 22 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (11) , 5840
Feasibility of Implementing Motion-Compensated Magnetic Resonance Imaging Reconstruction on Graphics Processing Units Using Compute Unified Device Architecture
Motion correction in magnetic resonance imaging (MRI) has become increasingly complex due to the high computational demands of iterative reconstruction algorithms and the heterogeneity of emerging computing platforms. However, the clinical applicability of these methods requires fast processing to ensure rapid and accurate diagnostics. Graphics processing units (GPUs) have demonstrated substantial performance gains in various reconstruction tasks. In this work, we present a GPU implementation of the reconstruction kernel for the generalized reconstruction by inversion of coupled systems (GRICS), an iterative joint optimization approach that enables 3D high-resolution image reconstruction with motion correction. Three implementations were compared: (i) a C++ CPU version, (ii) a Matlab–GPU version (with minimal code modifications allowing data storage in GPU memory), and (iii) a native GPU version using CUDA. Six distinct datasets, including various motion types, were tested. The results showed that the Matlab–GPU approach achieved speedups ranging from 1.2× to 2.0× compared to the CPU implementation, whereas the native CUDA version attained speedups of 9.7× to 13.9×. Across all datasets, the normalized root mean square error (NRMSE) remained on the order of to , indicating that the CUDA-accelerated method preserved image quality. Furthermore, a roofline analysis was conducted to quantify the kernel’s performance on one of the evaluated datasets. The kernel achieved 250 GFLOP/s, representing a 15.6× improvement over the performance of the Matlab–GPU version. These results confirm that GPU-based implementations of GRICS can drastically reduce reconstruction times while maintaining diagnostic fidelity, paving the way for more efficient clinical motion-compensated MRI workflows.- 22 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (11) , 5840
Open AccessFeasibility of Implementing Motion-Compensated Magnetic Resonance Imaging Reconstruction on Graphics Processing Units Using Compute Unified Device Architecture
Motion correction in magnetic resonance imaging (MRI) has become increasingly complex due to the high computational demands of iterative reconstruction algorithms and the heterogeneity of emerging computing platforms. However, the clinical applicability of these methods requires fast processing to ensure rapid and accurate diagnostics. Graphics processing units (GPUs) have demonstrated substantial performance gains in various reconstruction tasks. In this work, we present a GPU implementation of the reconstruction kernel for the generalized reconstruction by inversion of coupled systems (GRICS), an iterative joint optimization approach that enables 3D high-resolution image reconstruction with motion correction. Three implementations were compared: (i) a C++ CPU version, (ii) a Matlab–GPU version (with minimal code modifications allowing data storage in GPU memory), and (iii) a native GPU version using CUDA. Six distinct datasets, including various motion types, were tested. The results showed that the Matlab–GPU approach achieved speedups ranging from 1.2× to 2.0× compared to the CPU implementation, whereas the native CUDA version attained speedups of 9.7× to 13.9×. Across all datasets, the normalized root mean square error (NRMSE) remained on the order of to , indicating that the CUDA-accelerated method preserved image quality. Furthermore, a roofline analysis was conducted to quantify the kernel’s performance on one of the evaluated datasets. The kernel achieved 250 GFLOP/s, representing a 15.6× improvement over the performance of the Matlab–GPU version. These results confirm that GPU-based implementations of GRICS can drastically reduce reconstruction times while maintaining diagnostic fidelity, paving the way for more efficient clinical motion-compensated MRI workflows. - Open Access
Complete reconstruction of the tongue contour through acoustic to articulatory inversion using real-time MRI data
Acoustic articulatory inversion is a major processing challenge, with a wide range of applications from speech synthesis to feedback systems for language learning and rehabilitation. In recent years, deep learning methods have been applied to the inversion of less than a dozen geometrical positions corresponding to sensors glued to easily accessible articulators. It is therefore impossible to know the shape of the whole tongue from root to tip. In this work, we use high-quality real-time MRI data to track the contour of the tongue. The data used to drive the inversion are therefore the unstructured speech signal and the tongue contours. Several architectures relying on a Bi-MSTM including or not an autoencoder to reduce the dimensionality of the latent space, using or not the phonetic segmentation have been explored. The results show that the tongue contour can be recovered with a median accuracy of 2.21 mm (or 1.37 pixel) taking a context of 1 MFCC frame (static, delta and double-delta cepstral features).
Open AccessComplete reconstruction of the tongue contour through acoustic to articulatory inversion using real-time MRI data
Acoustic articulatory inversion is a major processing challenge, with a wide range of applications from speech synthesis to feedback systems for language learning and rehabilitation. In recent years, deep learning methods have been applied to the inversion of less than a dozen geometrical positions corresponding to sensors glued to easily accessible articulators. It is therefore impossible to know the shape of the whole tongue from root to tip. In this work, we use high-quality real-time MRI data to track the contour of the tongue. The data used to drive the inversion are therefore the unstructured speech signal and the tongue contours. Several architectures relying on a Bi-MSTM including or not an autoencoder to reduce the dimensionality of the latent space, using or not the phonetic segmentation have been explored. The results show that the tongue contour can be recovered with a median accuracy of 2.21 mm (or 1.37 pixel) taking a context of 1 MFCC frame (static, delta and double-delta cepstral features).
- Open Access
- 23 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (21) , 9663
Performance Study of an MRI Motion-Compensated Reconstruction Program on Intel CPUs, AMD EPYC CPUs, and NVIDIA GPUs
Motion-compensated image reconstruction enables new clinical applications of Magnetic Resonance Imaging (MRI), but it relies on computationally intensive algorithms. This study focuses on the Generalized Reconstruction by Inversion of Coupled Systems (GRICS) program, applied to the reconstruction of 3D images in cases of non-rigid or rigid motion. It uses hybrid parallelization with the MPI (Message Passing Interface) and OpenMP (Open Multi-Processing). For clinical integration, the GRICS needs to efficiently harness the computational resources of compute nodes. We aim to improve the GRICS’s performance without any code modification. This work presents a performance study of GRICS on two CPU architectures: Intel Xeon Gold and AMD EPYC. The roofline model is used to study the software–hardware interaction and quantify the code’s performance. For CPU–GPU comparison purposes, we propose a preliminary MATLAB–GPU implementation of the GRICS’s reconstruction kernel. We establish the roofline model of the kernel on two NVIDIA GPU architectures: Quadro RTX 5000 and A100. After the performance study, we propose some optimization patterns for the code’s execution on CPUs, first considering only the OpenMP implementation using thread binding and affinity and appropriate architecture-compilation flags and then looking for the optimal combination of MPI processes and OpenMP threads in the case of the hybrid MPI–OpenMP implementation. The results show that the GRICS performed well on the AMD EPYC CPUs, with an architectural efficiency of 52%. The kernel’s execution was fast on the NVIDIA A100 GPU, but the roofline model reported low architectural efficiency and utilization.
- 23 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (21) , 9663
Open AccessPerformance Study of an MRI Motion-Compensated Reconstruction Program on Intel CPUs, AMD EPYC CPUs, and NVIDIA GPUs
Motion-compensated image reconstruction enables new clinical applications of Magnetic Resonance Imaging (MRI), but it relies on computationally intensive algorithms. This study focuses on the Generalized Reconstruction by Inversion of Coupled Systems (GRICS) program, applied to the reconstruction of 3D images in cases of non-rigid or rigid motion. It uses hybrid parallelization with the MPI (Message Passing Interface) and OpenMP (Open Multi-Processing). For clinical integration, the GRICS needs to efficiently harness the computational resources of compute nodes. We aim to improve the GRICS’s performance without any code modification. This work presents a performance study of GRICS on two CPU architectures: Intel Xeon Gold and AMD EPYC. The roofline model is used to study the software–hardware interaction and quantify the code’s performance. For CPU–GPU comparison purposes, we propose a preliminary MATLAB–GPU implementation of the GRICS’s reconstruction kernel. We establish the roofline model of the kernel on two NVIDIA GPU architectures: Quadro RTX 5000 and A100. After the performance study, we propose some optimization patterns for the code’s execution on CPUs, first considering only the OpenMP implementation using thread binding and affinity and appropriate architecture-compilation flags and then looking for the optimal combination of MPI processes and OpenMP threads in the case of the hybrid MPI–OpenMP implementation. The results show that the GRICS performed well on the AMD EPYC CPUs, with an architectural efficiency of 52%. The kernel’s execution was fast on the NVIDIA A100 GPU, but the roofline model reported low architectural efficiency and utilization.
- 10 November 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 243, 107907
Automatic segmentation of vocal tract articulators in real-time magnetic resonance imaging
- 10 November 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 243, 107907
Automatic segmentation of vocal tract articulators in real-time magnetic resonance imaging
- Open Access
- 20 October 2023
- Published by MDPI AG in Journal of Imaging
- Vol. 9 (10) , 233
Super-Resolved Dynamic 3D Reconstruction of the Vocal Tract during Natural Speech
MRI is the gold standard modality for speech imaging. However, it remains relatively slow, which complicates imaging of fast movements. Thus, an MRI of the vocal tract is often performed in 2D. While 3D MRI provides more information, the quality of such images is often insufficient. The goal of this study was to test the applicability of super-resolution algorithms for dynamic vocal tract MRI. In total, 25 sagittal slices of 8 mm with an in-plane resolution of 1.6 × 1.6 mm2 were acquired consecutively using a highly-undersampled radial 2D FLASH sequence. The volunteers were reading a text in French with two different protocols. The slices were aligned using the simultaneously recorded sound. The super-resolution strategy was used to reconstruct 1.6 × 1.6 × 1.6 mm3 isotropic volumes. The resulting images were less sharp than the native 2D images but demonstrated a higher signal-to-noise ratio. It was also shown that the super-resolution allows for eliminating inconsistencies leading to regular transitions between the slices. Additionally, it was demonstrated that using visual stimuli and shorter text fragments improves the inter-slice consistency and the super-resolved image sharpness. Therefore, with a correct speech task choice, the proposed method allows for the reconstruction of high-quality dynamic 3D volumes of the vocal tract during natural speech.
- 20 October 2023
- Published by MDPI AG in Journal of Imaging
- Vol. 9 (10) , 233
Open AccessSuper-Resolved Dynamic 3D Reconstruction of the Vocal Tract during Natural Speech
MRI is the gold standard modality for speech imaging. However, it remains relatively slow, which complicates imaging of fast movements. Thus, an MRI of the vocal tract is often performed in 2D. While 3D MRI provides more information, the quality of such images is often insufficient. The goal of this study was to test the applicability of super-resolution algorithms for dynamic vocal tract MRI. In total, 25 sagittal slices of 8 mm with an in-plane resolution of 1.6 × 1.6 mm2 were acquired consecutively using a highly-undersampled radial 2D FLASH sequence. The volunteers were reading a text in French with two different protocols. The slices were aligned using the simultaneously recorded sound. The super-resolution strategy was used to reconstruct 1.6 × 1.6 × 1.6 mm3 isotropic volumes. The resulting images were less sharp than the native 2D images but demonstrated a higher signal-to-noise ratio. It was also shown that the super-resolution allows for eliminating inconsistencies leading to regular transitions between the slices. Additionally, it was demonstrated that using visual stimuli and shorter text fragments improves the inter-slice consistency and the super-resolved image sharpness. Therefore, with a correct speech task choice, the proposed method allows for the reconstruction of high-quality dynamic 3D volumes of the vocal tract during natural speech.
- 13 February 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (4) , 1123-1124
Editorial for “Simultaneous Highly Efficient Contrast‐Free Lumen and Vessel Wall MR Imaging for Anatomical Assessment of Aortic Disease”
- 13 February 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (4) , 1123-1124
Editorial for “Simultaneous Highly Efficient Contrast‐Free Lumen and Vessel Wall MR Imaging for Anatomical Assessment of Aortic Disease”