Miguel A. Frias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Miguel A. Frias has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Nicolas Vuilleumier
Department of Medicine, Medical Faculty, Geneva University, Geneva, Switzerland
4 shared publicationsJulien Virzi
Division of Laboratory Medicine, Diagnostic Department, Geneva University Hospitals, 4 rue Gabrielle-Perret-Gentil, 1205 Geneva, Switzerland; Department of Medical Specialties, Faculty of Medicine, University of Geneva, 1 rue Michel Servet, 1205 Geneva, Switzerland
2 shared publications- Nicolas Vuilleumier
Division of Laboratory Medicine, Diagnostic Department, Geneva University Hospitals
2 shared publications Richard W. James
Division of Endocrinology, Diabetes, Nutrition and Patient Education, Department of Medicine, University Hospitals of Geneva and University of Geneva, Geneva, Switzerland
2 shared publications- Anouar Hafiane
Department of Medicine, Faculty of Medicine, Research Institute of the McGill University Health Centre, Montreal, Canada
1 shared publication Aurélien Thomas
Unit of Toxicology, University Centre of Legal Medicine, Lausanne‐Geneva, Switzerland
1 shared publication
Latest Publications
- Open Access
- 10 February 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (4) , 386
Ferritin: A Biomarker Requiring Caution in Clinical Decision
Objectives. To determine the ferritin inter-assay differences between three “Conformité Européenne” (CE) marked tests, the impact on reference intervals (RI), and the proportion of individuals with iron deficiency (ID), we used plasma and serum from healthy blood donors (HBD) recruited in three different Switzerland regions. Design and Methods. Heparinized plasma and serum from HBD were obtained from three different transfusion centers in Switzerland (Fribourg, Geneva, and Neuchatel). One hundred forty samples were recruited per center and per matrix, with a gender ratio of 50%, for a total of 420 HBD samples available per matrix. On both matrices, ferritin concentrations were quantified by three different laboratories using electrochemiluminescence (ECL), latex immunoturbidimetric assay (LIA), and luminescent oxygen channeling immunoassay (LOCI) assays, respectively. The degree of agreement between matrices and between the three sites/methods was assessed by Passing–Bablok and we evaluated the proportion of individuals deemed to have ID per method. Results. Overall, no difference between serum and heparinized plasma ferritin values was observed according to Passing–Bablok analyses (proportional bias range: 1.0–3.0%; maximum constant bias: 1.84 µg/L). Significant median ferritin differences (p < 0.001 according to Kruskal–Wallis test) were observed between the three methods (i.e., 83.6 µg/L, 103.5 µg/L, and 62.1 µg/L for ECL, LIA, and LOCI in heparinized plasma, respectively), with proportional bias varying significantly between ±16% and ±32% on serum and from ±14% to ±35% on plasma with no sign of gender-related differences. Affecting the lower end of RI, the proportion of ID per method substantially varied between 4.76% (20/420) for ECL, 2.86% (12/420) for LIA, and 9.05% (38/420) for LOCI. Conclusions. Serum and heparinized plasma are exchangeable for ferritin assessment. However, the order of magnitude of ferritin differences across methods and HBD recruitment sites could lead to diagnostic errors if uniform RI were considered. Challenging the recently proposed use of uniform ferritin thresholds, our results highlight the importance of method- and region-specific RI for ferritin due to insufficient inter-assay harmonization. Failing to do so significantly impacts ID diagnosis.
- 10 February 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (4) , 386
Open AccessFerritin: A Biomarker Requiring Caution in Clinical Decision
Objectives. To determine the ferritin inter-assay differences between three “Conformité Européenne” (CE) marked tests, the impact on reference intervals (RI), and the proportion of individuals with iron deficiency (ID), we used plasma and serum from healthy blood donors (HBD) recruited in three different Switzerland regions. Design and Methods. Heparinized plasma and serum from HBD were obtained from three different transfusion centers in Switzerland (Fribourg, Geneva, and Neuchatel). One hundred forty samples were recruited per center and per matrix, with a gender ratio of 50%, for a total of 420 HBD samples available per matrix. On both matrices, ferritin concentrations were quantified by three different laboratories using electrochemiluminescence (ECL), latex immunoturbidimetric assay (LIA), and luminescent oxygen channeling immunoassay (LOCI) assays, respectively. The degree of agreement between matrices and between the three sites/methods was assessed by Passing–Bablok and we evaluated the proportion of individuals deemed to have ID per method. Results. Overall, no difference between serum and heparinized plasma ferritin values was observed according to Passing–Bablok analyses (proportional bias range: 1.0–3.0%; maximum constant bias: 1.84 µg/L). Significant median ferritin differences (p < 0.001 according to Kruskal–Wallis test) were observed between the three methods (i.e., 83.6 µg/L, 103.5 µg/L, and 62.1 µg/L for ECL, LIA, and LOCI in heparinized plasma, respectively), with proportional bias varying significantly between ±16% and ±32% on serum and from ±14% to ±35% on plasma with no sign of gender-related differences. Affecting the lower end of RI, the proportion of ID per method substantially varied between 4.76% (20/420) for ECL, 2.86% (12/420) for LIA, and 9.05% (38/420) for LOCI. Conclusions. Serum and heparinized plasma are exchangeable for ferritin assessment. However, the order of magnitude of ferritin differences across methods and HBD recruitment sites could lead to diagnostic errors if uniform RI were considered. Challenging the recently proposed use of uniform ferritin thresholds, our results highlight the importance of method- and region-specific RI for ferritin due to insufficient inter-assay harmonization. Failing to do so significantly impacts ID diagnosis.
- Open Access
- 26 March 2021
- Published by Wiley in Physiological Reports
- Vol. 9 (6) , e14786
Sphingosine‐1‐phosphate as a key player of insulin secretion induced by high‐density lipoprotein treatment
HDL improves insulin secretion by beta cells S1P plays a role in HDL‐induced insulin secretion HDL increases intracellular S1P content.
- 26 March 2021
- Published by Wiley in Physiological Reports
- Vol. 9 (6) , e14786
Open AccessSphingosine‐1‐phosphate as a key player of insulin secretion induced by high‐density lipoprotein treatment
HDL improves insulin secretion by beta cells S1P plays a role in HDL‐induced insulin secretion HDL increases intracellular S1P content.
- 1 March 2020
- Published by Elsevier in Metabolism
- Vol. 104, 154141
High-density lipoprotein cholesterol efflux capacity and cardiovascular risk in autoimmune and non-autoimmune diseases
- 1 March 2020
- Published by Elsevier in Metabolism
- Vol. 104, 154141
High-density lipoprotein cholesterol efflux capacity and cardiovascular risk in autoimmune and non-autoimmune diseases
- 1 June 2019
- Published by Elsevier in Journal of Immunological Methods
- Vol. 469, 33-41
ELISA methods comparison for the detection of auto-antibodies against apolipoprotein A1
- 1 June 2019
- Published by Elsevier in Journal of Immunological Methods
- Vol. 469, 33-41
ELISA methods comparison for the detection of auto-antibodies against apolipoprotein A1
- 1 February 2018
- Published by Elsevier in Clinical Biochemistry
- Vol. 52, 142-147
Impact of long distance rowing on biological health: A pilot study
- 1 February 2018
- Published by Elsevier in Clinical Biochemistry
- Vol. 52, 142-147
Impact of long distance rowing on biological health: A pilot study
- Open Access
- 22 January 2018
- Published by Frontiers Media SA in Frontiers in Pharmacology
- Vol. 8, 989
Pharmacological Intervention to Modulate HDL: What Do We Target?
The cholesterol concentrations of low-density lipoprotein (LDL) and high-density lipoprotein (HDL) have traditionally served as risk factors for cardiovascular disease. As such, novel therapeutic interventions aiming to raise HDL cholesterol have been tested in the clinical setting. However, most trials led to a significant increase in HDL cholesterol with no improvement in cardiovascular events. The complexity of the HDL particle, which exerts multiple physiological functions and is comprised of a number of subclasses, has raised the question as to whether there should be more focus on HDL subclass and function rather than cholesterol quantity. We review current data regarding HDL subclasses and subclass-specific functionality and highlight how current lipid modifying drugs such as statins, cholesteryl ester transfer protein inhibitors, fibrates and niacin often increase cholesterol concentrations of specific HDL subclasses. In addition this review sets out arguments suggesting that the HDL3 subclass may provide better protective effects than HDL2.
- 22 January 2018
- Published by Frontiers Media SA in Frontiers in Pharmacology
- Vol. 8, 989
Open AccessPharmacological Intervention to Modulate HDL: What Do We Target?
The cholesterol concentrations of low-density lipoprotein (LDL) and high-density lipoprotein (HDL) have traditionally served as risk factors for cardiovascular disease. As such, novel therapeutic interventions aiming to raise HDL cholesterol have been tested in the clinical setting. However, most trials led to a significant increase in HDL cholesterol with no improvement in cardiovascular events. The complexity of the HDL particle, which exerts multiple physiological functions and is comprised of a number of subclasses, has raised the question as to whether there should be more focus on HDL subclass and function rather than cholesterol quantity. We review current data regarding HDL subclasses and subclass-specific functionality and highlight how current lipid modifying drugs such as statins, cholesteryl ester transfer protein inhibitors, fibrates and niacin often increase cholesterol concentrations of specific HDL subclasses. In addition this review sets out arguments suggesting that the HDL3 subclass may provide better protective effects than HDL2.