Fengjuan Jing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fengjuan Jing has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Behnam Akhavan
School of Biomedical Engineering, The University of Sydney, Sydney, NSW 2006, Australia
4 shared publications Dong Xie
School of Physics, Southwest Jiaotong University, Chengdu, 610031, China
3 shared publicationsNan Huang
Key Laboratory of Advanced Technologies of Materials, Ministry of Education of China, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
3 shared publicationsYongxiang Leng
Key Laboratory of Advanced Technologies of Materials, Ministry of Education of China, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
3 shared publicationsDan Cheng
Key Laboratory of Advanced Technologies of Materials, Ministry of Education of China, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, China
2 shared publications- Dong Xie
Key Laboratory of Advanced Technologies of Materials, Ministry of Education of China, School of Physical Science and Technology, Southwest Jiaotong University, Chengdu 610031, China
2 shared publications
Latest Publications
- 27 December 2025
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 350, 127394
Interfacial engineering of zirconia-toughened alumina (ZTA) ceramics: Unveiling cu ion-mediated bio-film formation mechanism
- 27 December 2025
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 350, 127394
Interfacial engineering of zirconia-toughened alumina (ZTA) ceramics: Unveiling cu ion-mediated bio-film formation mechanism
- Open Access
Evaluation of the Crystal Structure and Mechanical Properties of Cu Doped TiN Films
In this study, TiN films doped with different copper contents (TiCuN) were prepared by using direct current magnetron sputtering method. The effects of Cu doping on composition, structure, and mechanical properties of TiN films were studied by energy-dispersive spectroscopy (EDS), X-ray diffraction (XRD), a Vickers microhardnessmeter, and density functional theory (DFT). The results of experimental and DFT study showed that Cu mainly replaced Ti atoms in TiN to form replacement solid solution doping. When Cu replaced Ti in TiN, a weak Cu-N (bond population varied from 0.06 to 0.11) covalent bond formed; meanwhile, the bonding strength of Ti-N (bond population varied from 0.29 to 0.4) bond adjacent to Cu increased. When Cu content was low, a small number of weak Cu-N bonds were formed, with strengthened Ti-N bond near Cu atom, resulting in an increased hardness of Cu doped TiN films. According to the theory of weak bonds, when the Cu content was increased further, the number of weak Cu-N bonds increased and TiCuN hardness decreased. With an increase in Cu content, it was found the toughness of TiCuN also increased. The results of this study will provide a theoretical and experimental guidance for improving the toughness and deformation resistance of TiN, which has a potential application in the surface modification of medical devices.
Open AccessEvaluation of the Crystal Structure and Mechanical Properties of Cu Doped TiN Films
In this study, TiN films doped with different copper contents (TiCuN) were prepared by using direct current magnetron sputtering method. The effects of Cu doping on composition, structure, and mechanical properties of TiN films were studied by energy-dispersive spectroscopy (EDS), X-ray diffraction (XRD), a Vickers microhardnessmeter, and density functional theory (DFT). The results of experimental and DFT study showed that Cu mainly replaced Ti atoms in TiN to form replacement solid solution doping. When Cu replaced Ti in TiN, a weak Cu-N (bond population varied from 0.06 to 0.11) covalent bond formed; meanwhile, the bonding strength of Ti-N (bond population varied from 0.29 to 0.4) bond adjacent to Cu increased. When Cu content was low, a small number of weak Cu-N bonds were formed, with strengthened Ti-N bond near Cu atom, resulting in an increased hardness of Cu doped TiN films. According to the theory of weak bonds, when the Cu content was increased further, the number of weak Cu-N bonds increased and TiCuN hardness decreased. With an increase in Cu content, it was found the toughness of TiCuN also increased. The results of this study will provide a theoretical and experimental guidance for improving the toughness and deformation resistance of TiN, which has a potential application in the surface modification of medical devices.
- Open Access
Ti–Cu Coatings Deposited by a Combination of HiPIMS and DC Magnetron Sputtering: The Role of Vacuum Annealing on Cu Diffusion, Microstructure, and Corrosion Resistance
Titanium-copper (Ti–Cu) coatings have attracted extensive attention in the surface modification of industrial and biomedical materials due to their excellent physical and chemical properties and biocompatibility. Here, Ti–Cu coatings are fabricated using a combination of high-power pulsed magnetron sputtering (HPPMS; also known as high power impulse magnetron sputtering (HiPIMS)) and DC magnetron sputtering followed by vacuum annealing at varied temperatures (300, 400, and 500 °C). X-ray diffraction (XRD), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS) data showed that Ti, Cu, and CuTi3 are mainly formed in the coatings before annealing, while Ti3O, Cu2O, and CuTi3 are the main compounds present in the annealed coatings. The cross-sectional TEM micrographs and corresponding EDS results provided evidence that Ti is mainly present on the surface and interfaces of the silicon substrate and the Ti–Cu coatings annealed at 500 °C, while the bulk of the coatings is enriched with Cu. The resistivity of the coatings decreased with increasing the annealing temperature from 300 to 500 °C. Based on self-corrosion current density data, the Ti–Cu coating annealed at 300 °C showed similar corrosion performance compared to the as-deposited Ti–Cu coating, while the corrosion rate increased for the Ti–Cu coatings annealed at 400 and 500 °C. Stable release of copper ions in PBS (cumulative released concentration of 0.8–1.0 μM) for up to 30 days was achieved for all the annealed coatings. Altogether, the results demonstrate that vacuum annealing is a simple and viable approach to tune the Cu diffusion and microstructure of the Ti–Cu coatings, thereby modulating their electrical resistivity, corrosion performance, and Cu ion release behavior.
Open AccessTi–Cu Coatings Deposited by a Combination of HiPIMS and DC Magnetron Sputtering: The Role of Vacuum Annealing on Cu Diffusion, Microstructure, and Corrosion Resistance
Titanium-copper (Ti–Cu) coatings have attracted extensive attention in the surface modification of industrial and biomedical materials due to their excellent physical and chemical properties and biocompatibility. Here, Ti–Cu coatings are fabricated using a combination of high-power pulsed magnetron sputtering (HPPMS; also known as high power impulse magnetron sputtering (HiPIMS)) and DC magnetron sputtering followed by vacuum annealing at varied temperatures (300, 400, and 500 °C). X-ray diffraction (XRD), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS) data showed that Ti, Cu, and CuTi3 are mainly formed in the coatings before annealing, while Ti3O, Cu2O, and CuTi3 are the main compounds present in the annealed coatings. The cross-sectional TEM micrographs and corresponding EDS results provided evidence that Ti is mainly present on the surface and interfaces of the silicon substrate and the Ti–Cu coatings annealed at 500 °C, while the bulk of the coatings is enriched with Cu. The resistivity of the coatings decreased with increasing the annealing temperature from 300 to 500 °C. Based on self-corrosion current density data, the Ti–Cu coating annealed at 300 °C showed similar corrosion performance compared to the as-deposited Ti–Cu coating, while the corrosion rate increased for the Ti–Cu coatings annealed at 400 and 500 °C. Stable release of copper ions in PBS (cumulative released concentration of 0.8–1.0 μM) for up to 30 days was achieved for all the annealed coatings. Altogether, the results demonstrate that vacuum annealing is a simple and viable approach to tune the Cu diffusion and microstructure of the Ti–Cu coatings, thereby modulating their electrical resistivity, corrosion performance, and Cu ion release behavior.
- 1 November 2020
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 116, 111198
Reactive magnetron co-sputtering of Ti-xCuO coatings: Multifunctional interfaces for blood-contacting devices
- 1 November 2020
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 116, 111198
Reactive magnetron co-sputtering of Ti-xCuO coatings: Multifunctional interfaces for blood-contacting devices
- 1 November 2019
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 104, 109969
Multifunctional Ti-xCu coatings for cardiovascular interfaces: Control of microstructure and surface chemistry
- 1 November 2019
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 104, 109969
Multifunctional Ti-xCu coatings for cardiovascular interfaces: Control of microstructure and surface chemistry
- 23 January 2018
- Published by Wiley in Advanced Materials Interfaces
- Vol. 5 (6)
Catalytic Formation of Nitric Oxide Mediated by Ti–Cu Coatings Provides Multifunctional Interfaces for Cardiovascular Applications
An ideal surface of a cardiovascular device, such as a stent, must be multifunctional: promoting endothelialization to regenerate the vessel's natural endothelial cell (EC) lining; inhibiting the proliferation of smooth muscle cells that occlude vessels; and simultaneously mitigating thrombosis that leads to the spontaneous formation of blood clots. Here it is reported on Ti–Cu interfaces that demonstrate this required multifunctionality through the controlled release of copper ions that induce the catalytic formation of nitric oxide (NO). Ti–Cu coatings, deposited on stainless steel substrates via direct current magnetron sputtering, demonstrate a significantly higher NO‐release catalytic activity compared to Ti coatings due to release of copper ions. Ti–Cu surfaces that stimulate optimum catalytic formation of NO significantly decrease smooth muscle cell proliferation, inhibit platelet adhesion, and improve endothelial cell EC compatibility. The development of such catalytic surfaces through a simple sputtering method holds great promise for the fabrication of advanced multifunctional cardiovascular devices such as stents and coronary implants.
- 23 January 2018
- Published by Wiley in Advanced Materials Interfaces
- Vol. 5 (6)
Catalytic Formation of Nitric Oxide Mediated by Ti–Cu Coatings Provides Multifunctional Interfaces for Cardiovascular Applications
An ideal surface of a cardiovascular device, such as a stent, must be multifunctional: promoting endothelialization to regenerate the vessel's natural endothelial cell (EC) lining; inhibiting the proliferation of smooth muscle cells that occlude vessels; and simultaneously mitigating thrombosis that leads to the spontaneous formation of blood clots. Here it is reported on Ti–Cu interfaces that demonstrate this required multifunctionality through the controlled release of copper ions that induce the catalytic formation of nitric oxide (NO). Ti–Cu coatings, deposited on stainless steel substrates via direct current magnetron sputtering, demonstrate a significantly higher NO‐release catalytic activity compared to Ti coatings due to release of copper ions. Ti–Cu surfaces that stimulate optimum catalytic formation of NO significantly decrease smooth muscle cell proliferation, inhibit platelet adhesion, and improve endothelial cell EC compatibility. The development of such catalytic surfaces through a simple sputtering method holds great promise for the fabrication of advanced multifunctional cardiovascular devices such as stents and coronary implants.
- 1 January 2018
- Published by Shanghai Institute of Ceramics in Journal of Inorganic Materials
- Vol. 33 (10) , 1089-1096
Microstructure of TiCuO Films on Copper Ion Release and Endothelial Cell Behavior
- 1 January 2018
- Published by Shanghai Institute of Ceramics in Journal of Inorganic Materials
- Vol. 33 (10) , 1089-1096
Microstructure of TiCuO Films on Copper Ion Release and Endothelial Cell Behavior