NSNabil Simaan

Nabil Simaan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nabil Simaan has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enabling Technology for Microvascular Stenting in Ophthalmic Surgery

    by Wei Wei, Claire Popplewell, Stanley Chang, Howard F. Fine, Nabil Simaan

    Microstenting is a potentially revolutionary approach to surgical treatment of microvascular retinal disorders that do not resolve using pharmaceutical treatment. This article presents a novel device called a stent deployment unit (SDU) that aims at enabling microstent placement in ophthalmic surgery. The clinical motivation for this work is highlighted in context of microvascular retinal surgery. The proposed SDU is designed for intraocular adjustment of the approach angle and the position of the stent with respect to the retina. The feasibility of this device is experimentally evaluated on chick chorioallantoic membranes and on agar vascular models. Experiments show dependency on the approach angle with respect to the vasculature and on the mobility of the vasculature. Successful placement of stents was achieved in both experimental media. To the best of our knowledge, this pioneering work is the first to demonstrate successful stent deployment in a scale suitable for retinal surgery. We believe that this technique has the promise of enabling effective vascular treatments for blinding conditions such as central and branch retinal vein occlusion.


  • Design of Planar Parallel Robots With Preloaded Flexures for Guaranteed Backlash Prevention

    by Wei Wei, Nabil Simaan

    The precision of parallel robots is limited by backlash in their joints. This paper investigates algorithms for designing inexpensive planar parallel robots with prescribed backlash-free workspace. The method of closing the backlash of the actuators uses preloaded flexible joints to replace the passive joints. These flexible joints may be made using standard joints with preloaded springs or by using preloaded flexure joints. Given a norm-bounded wrench acting on the robot, an algorithm is presented for determining the required preload for the flexible joints in order to guarantee backlash-free operation along a path or within a prescribed workspace. An investigation of the effects of the preloaded flexible joints on the stiffness is carried out using performance measures comparing the same robot with or without preloaded joints. These performance measures use an extended stiffness definition based on three noncollinear vertices on the moving platform. This paper presents simulations of the statics, stiffness, and backlash prevention algorithm, followed by experimental validations.


  • Top Cited Papers

    Analytic Formulation for Kinematics, Statics, and Shape Restoration of Multibackbone Continuum Robots Via Elliptic Integrals

    by Kai Xu, Nabil Simaan

    This paper presents a novel and unified analytic formulation for kinematics, statics, and shape restoration of multiple-backbone continuum robots. These robots achieve actuation redundancy by independently pulling and pushing three backbones to carry out a bending motion of two-degrees-of-freedom (DoF). A solution framework based on constraints of geometric compatibility and static equilibrium is derived using elliptic integrals. This framework allows the investigation of the effects of different external loads and actuation redundancy resolutions on the shape variations in these continuum robots. The simulation and experimental validation results show that these continuum robots bend into an exact circular shape for one particular actuation resolution. This provides a proof to the ubiquitously accepted circular-shape assumption in deriving kinematics for continuum robots. The shape variations due to various actuation redundancy resolutions are also investigated. The simulation results show that these continuum robots have the ability to redistribute loads among their backbones without introducing significant shape variations. A strategy for partially restoring the shape of the externally loaded continuum robots is proposed. The simulation results show that either the tip orientation or the tip position can be successfully restored.


  • Top Cited Papers

    Design and Integration of a Telerobotic System for Minimally Invasive Surgery of the Throat

    by Nabil Simaan, Kai Xu, Wei Wei, Ankur Kapoor, Peter Kazanzides, Russell Taylor, Paul Flint

    In this paper we present the clinical motivation, design specifications, kinematics, statics, and actuation compensation for a newly constructed telerobotic system for Minimally Invasive Surgery (MIS) of the throat. A hybrid dual-arm telesurgical slave, with 20 joint-space Degrees-of-Freedom (DoFs), is used in this telerobotic system to provide the necessary dexterity in deep surgical fields such as the throat. The telerobotic slave uses novel continuum robots that use multiple super-elastic backbones for actuation and structural integrity. We present the kinematics of the telesurgical slave and methods for actuation compensation to cancel the effects of backlash, friction, and flexibility of the actuation lines. A method for actuation compensation is presented in order to overcome uncertainties of modeling, friction, and backlash. This method uses a tiered hierarchy of two novel approaches of actuation compensation for remotely actuated snake-like robots. The tiered approach for actuation compensation uses compensation in both joint space and configuration space of the continuum robots. These hybrid actuation compensation schemes use intrinsic model information and external data through a recursive linear estimation algorithm and involve compensation using configuration space and joint space variables. Experimental results validate the ability of our integrated telemanipulation system through experiments of suturing and knot tying in confined spaces.


  • Design Considerations for a Minimally Invasive High-Throughput Automation System for Radiation Biodosimetry

    by A. Salerno, J. Zhang, A. Bhatla, O. V. Lyulko, J. Nie, A. Dutta, G. Garty, N. Simaan, G. Randers-Pehrson, Y. L. Yao, et al.

    Design aspects of a minimally invasive high-throughput automation system for radiation biodosimetry are reported. The system, currently under development, relies on robotic devices and advanced high-speed automated image acquisition to perform mass triage following a radiological event. A design concept of the automation system is proposed based on the use of an input stage, a centrifuge module, a cell harvesting system, a liquid handling module, an imaging system and a service robot. The biological assays are described along with an analysis of the throughput requirements. The special requirements imposed by bioassay automation, system throughput and minimal invasiveness lead to the design of a custom-made multipurpose gripper and a cell harvesting module. Results on the embodiment design of these modules are provided. A prototype of the automation system is described.


  • Design and Theoretical Evaluation of Micro-Surgical Manipulators for Orbital Manipulation and Intraocular Dexterity

    by Wei Wei, Roger Goldman, Nabil Simaan, Howard Fine, Stanley Chang

    This paper addresses the design considerations and dexterity evaluation of a novel hybrid two-armed micro-surgical slave robot equipped with intraocular dexterity devices. A unified framework for the kinematic modeling of this robot is presented while using the kinematic constraints stemming from the constrained motion of the eye. An augmented Jacobian describing the kinematics of the eye and the relative motion of each one of the two intraocular dexterity robots (IODR) is presented. Using this framework, the capabilities of this two-armed robot in performing dexterous intraocular operations are evaluated and compared to a similar robot without intraocular dexterity. The kinematic conditioning index (KCI) for the proposed robot is shown to be significant. The results presented show an increase of approximately 33% and 47% in translational and rotational KCI respectively


  • Snake-Like Units Using Flexible Backbones and Actuation Redundancy for Enhanced Miniaturization

    by N. Simaan

    This paper reports some recent analysis and modeling results obtained while developing a tele-robotic system for minimally invasive surgery of the throat. One of the main enabling components of this system is a Distal Dexterity Unit that implements a novel design using a flexible multi-backbone snake-like unit with actuation redundancy and push-pull actuation. The design of this snake-like unit is compared to other alternative designs that use a single flexible-backbone and wire-actuation. A unified kinematic and virtual work model is used to perform this comparison between a multi-backbone snake like unit with an equal-diameter snake-like unit using a single flexible backbone and wire actuation. The comparison is presented for several actuation redundancy resolutions that minimize the load on the flexible backbones. The results show that the multi-backbone design is superior to the alternative wire-actuated designs using a single flexible backbone. The advantages manifest in smaller required actuation forces on the backbones and, as a result, a reduced risk of buckling of the backbones and enhanced potential downsize scalability.