Xiaqing Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaqing Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Shengtao Fan
Sch. of Autom. Sci. & Electr. Eng., Beijing Univ. of Aeronaut. & Astronaut., Beijing
3 shared publicationsShuyou Guo
Electrical Engineering Department, Beijing Institute of Petrochemical Technology, BIPT, Beijing, P. R. China
2 shared publicationsLi Zuo
Electrical Engineering Department, Beijing Institute of Petrochemical Technology, BIPT, Beijing, P. R. China
1 shared publicationLuyan Bi
Sch. of Autom. Sci. & Electr. Eng., Beijing Univ. of Aeronaut. & Astronaut., Beijing
1 shared publicationYiming Zhou
Electrical Engineering Department, Beijing Institute of Petrochemical Technology, BIPT, Beijing, P. R. China
1 shared publicationYunhua Li
Sch. of Autom. Sci. & Electr. Eng., Beijing Univ. of Aeronaut. & Astronaut., Beijing
1 shared publication
Latest Publications
- 21 March 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 24 (2) , 552-560
A Method for the Calculation of Frequency-Dependent Transmission Line Transformation Matrices
A stable and efficient method for evaluating the transformation matrices of both overhead transmission lines and underground cables as smooth functions of frequency is presented. The proposed method is based on the postprocessing of the eigenvectors obtained by the conventional methods where optimization is employed to maximize the smoothness of the transformation matrices. Even in the case of the underground cable systems composed of several identical single core coaxial cables, where some of the eigenvalues become arbitrarily close at high frequencies, it is capable of producing smooth transformation matrices that can be accurately fitted with rational functions.
- 21 March 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 24 (2) , 552-560
A Method for the Calculation of Frequency-Dependent Transmission Line Transformation Matrices
A stable and efficient method for evaluating the transformation matrices of both overhead transmission lines and underground cables as smooth functions of frequency is presented. The proposed method is based on the postprocessing of the eigenvectors obtained by the conventional methods where optimization is employed to maximize the smoothness of the transformation matrices. Even in the case of the underground cable systems composed of several identical single core coaxial cables, where some of the eigenvalues become arbitrarily close at high frequencies, it is capable of producing smooth transformation matrices that can be accurately fitted with rational functions.
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Traveling Wave Characteristic Analysis of Arc Short Circuit and Metal Short Circuit Fault in DC Traction Power Supply System
To catch the information of the faults and to distinguish them as well is a challenging problem in the intelligent auto-reclosing sets of the direct current traction power supply system. The transient fault and the permanent fault can be equivalent to the arc short and the metal short. Based on transmission line theory and the difference of the energy attenuation speed under the two states, the theoretical method to distinguish the transient fault and the permanent fault is established. By B-spline binary wavelet, the characteristics of the faults are found out, and the result is satisfactory
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Traveling Wave Characteristic Analysis of Arc Short Circuit and Metal Short Circuit Fault in DC Traction Power Supply System
To catch the information of the faults and to distinguish them as well is a challenging problem in the intelligent auto-reclosing sets of the direct current traction power supply system. The transient fault and the permanent fault can be equivalent to the arc short and the metal short. Based on transmission line theory and the difference of the energy attenuation speed under the two states, the theoretical method to distinguish the transient fault and the permanent fault is established. By B-spline binary wavelet, the characteristics of the faults are found out, and the result is satisfactory
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21582181,p. 1-5
Research on Fault Diagnosis and Protect Model for DC Traction Power Supply System Based on Traveling Wave Theory
The paper analyses the limitation of the differentiation i-delta I protection method. It puts forward traveling wave protection method for the DC power supply system that is based on interrelated characteristics of the traveling wave and the unit impedance of the transmission line. The traveling wave protection method overcomes the disadvantage of the traditional method in which the protection action is affected by the overall impedance of the circuit, and thus improves the reliability and sensibility of the relay protection system. A great number of field tests are carried out and the research results are satisfactory
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21582181,p. 1-5
Research on Fault Diagnosis and Protect Model for DC Traction Power Supply System Based on Traveling Wave Theory
The paper analyses the limitation of the differentiation i-delta I protection method. It puts forward traveling wave protection method for the DC power supply system that is based on interrelated characteristics of the traveling wave and the unit impedance of the transmission line. The traveling wave protection method overcomes the disadvantage of the traditional method in which the protection action is affected by the overall impedance of the circuit, and thus improves the reliability and sensibility of the relay protection system. A great number of field tests are carried out and the research results are satisfactory