Yasushi Akazawa
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yasushi Akazawa has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Akio Nakagawa
Kobe Gakuin University
6 shared publications Keisuke Ueda
2 shared publicationsMasao Ikeda
2 shared publicationsMasao Tanaka
Div. Mech. Sci., Grad. Sch. Eng. Sci., Osaka University
2 shared publicationsMiwa Tokuda
Osaka University
2 shared publications- Shoji Morimoto
Department of Biomedical Engineer, Osaka Electro-Communication University, 1130-70 Kiyotaki, Shijonawate, Osaka, Japan
2 shared publications
Latest Publications
- 1 January 2008
- Published by Japan Society of Mechanical Engineers in The Proceedings of the JSME Symposium on Welfare Engineering
- Vol. 2008, 68-70
1C4-1 Instruction of direction where sound side is operated to apoplexy splinter paralytic arm training support robot
This paper describes a development of support robot for training of a Hemiplegia patient. This robot is based on technologies of power assisting suit. Our power assisting suit is constructed on the idea of "Soft-Mechtronics" that is safety and relief for human by flexible structures, pliable controls and soft actuators. We constructed this power assisting suit by plastic exoskeleton cloth and pneumatic rubber actuators. So the patient does not feel fear to this robot. Rehabilitation needs motivation of the patient. This robot moves paralysis side arm of patient based on signals from moving of health side arm.
- 1 January 2008
- Published by Japan Society of Mechanical Engineers in The Proceedings of the JSME Symposium on Welfare Engineering
- Vol. 2008, 68-70
1C4-1 Instruction of direction where sound side is operated to apoplexy splinter paralytic arm training support robot
This paper describes a development of support robot for training of a Hemiplegia patient. This robot is based on technologies of power assisting suit. Our power assisting suit is constructed on the idea of "Soft-Mechtronics" that is safety and relief for human by flexible structures, pliable controls and soft actuators. We constructed this power assisting suit by plastic exoskeleton cloth and pneumatic rubber actuators. So the patient does not feel fear to this robot. Rehabilitation needs motivation of the patient. This robot moves paralysis side arm of patient based on signals from moving of health side arm.
- 1 January 2008
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 20 (Supplement) , 4-6
Instruction of direction where sound side is operated to apoplexy splinter paralytic arm training support robot
- 1 January 2008
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 20 (Supplement) , 4-6
Instruction of direction where sound side is operated to apoplexy splinter paralytic arm training support robot
- 1 January 2007
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2007, _1A1-K05_1
1A1-K05 Development of Ankle-Foot Othosis Intelligently controlled by Shear-Type Compact MR Brake and its Control
MR fluid (Magneto-Rheological fluid) is a kind of functional fluid. In this study, we developed Shear-type Compact MR Brake (SCMR-Brake) applying shear mode of MR brake. To employ multi-layered and minute-gap structure, we developed SCMR-Brakes. By using this brake on the part of ankle torque control unit, we developed Controllable Ankle-Foot Orthosis, and controlled the ankle according to walking phases.
- 1 January 2007
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2007, _1A1-K05_1
1A1-K05 Development of Ankle-Foot Othosis Intelligently controlled by Shear-Type Compact MR Brake and its Control
MR fluid (Magneto-Rheological fluid) is a kind of functional fluid. In this study, we developed Shear-type Compact MR Brake (SCMR-Brake) applying shear mode of MR brake. To employ multi-layered and minute-gap structure, we developed SCMR-Brakes. By using this brake on the part of ankle torque control unit, we developed Controllable Ankle-Foot Orthosis, and controlled the ankle according to walking phases.
- 1 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21527431,p. 1114-1119
Research and Development of the Intelligently-Controlled Prosthetic Ankle Joint
The purpose of this study is to develop a prosthetic ankle joint intelligently controlled by specially designed linear MR (magneto-rheological) brake. MR fluid changes its rheology depending on the intension of an applied magnetic field. The brake using MR fluid (we call it MR brake) has a simple structure and can control its braking force with a low voltage. Prosthesis users often tumble because they don't have dorsiflexor, so that we propose putting MR brake taking the place of dorsiflexion. We hope that prosthesis users can walk more naturally and smoothly by use of developed intelligent prosthetic ankle joint with MR brake. We developed a prototype of it and evaluated it with walking experiments before. But there were some problems with the prototype in terms of hardware and experimental environments. Therefore we have developed a 2nd prototype of the intelligent prosthetic ankle joint with the MR brake, which was improved considering previous problems, and then we have carried out the walking experimental evaluation of it
- 1 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21527431,p. 1114-1119
Research and Development of the Intelligently-Controlled Prosthetic Ankle Joint
The purpose of this study is to develop a prosthetic ankle joint intelligently controlled by specially designed linear MR (magneto-rheological) brake. MR fluid changes its rheology depending on the intension of an applied magnetic field. The brake using MR fluid (we call it MR brake) has a simple structure and can control its braking force with a low voltage. Prosthesis users often tumble because they don't have dorsiflexor, so that we propose putting MR brake taking the place of dorsiflexion. We hope that prosthesis users can walk more naturally and smoothly by use of developed intelligent prosthetic ankle joint with MR brake. We developed a prototype of it and evaluated it with walking experiments before. But there were some problems with the prototype in terms of hardware and experimental environments. Therefore we have developed a 2nd prototype of the intelligent prosthetic ankle joint with the MR brake, which was improved considering previous problems, and then we have carried out the walking experimental evaluation of it
- 1 January 2001
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2001.13, 292-293
Switching viscosity of ankle foot orthosis joint : A prototype study
- 1 January 2001
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2001.13, 292-293
Switching viscosity of ankle foot orthosis joint : A prototype study
- 1 January 1997
- Published by Japan Society of Mechanical Engineers in TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
- Vol. 63 (607) , 816-822
Mechanical Characteristics of Ankle Foot Orthosis and its Effect on Human Gait.
- 1 January 1997
- Published by Japan Society of Mechanical Engineers in TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
- Vol. 63 (607) , 816-822
Mechanical Characteristics of Ankle Foot Orthosis and its Effect on Human Gait.
- 1 January 1992
- Published by Society of Biomechanisms Japan in Biomechanisms
- Vol. 11, 57-64
MEASUREMENT OF MULTI-AXIS JOINT ANGLES USING FLEXIBLE ELECTROGONIOMETERS
- 1 January 1992
- Published by Society of Biomechanisms Japan in Biomechanisms
- Vol. 11, 57-64
MEASUREMENT OF MULTI-AXIS JOINT ANGLES USING FLEXIBLE ELECTROGONIOMETERS