Shuo Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shuo Zhang has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Guibin Zou
School of Electrical Engineering, Shandong University, Jinan, China
23 shared publications Guibin Zou
Shandong University,School of Electrical Engineering,Ji'nan,China
15 shared publications- Xiuyan Wei
School of Electrical Engineering, Shandong University, Jinan, China
12 shared publications Chunhua Xu
Weihai Power Supply Company, State Grid-China, Weihai, China
8 shared publicationsChengquan Zhang
State Grid Shandong Weifang Electric Power Company,Weifang,China
6 shared publicationsXiuyan Wei
School of Electrical Engineering Shandong University,Jinan,China,250061
6 shared publications
Latest Publications
- Open Access
- 16 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 10109
Integrated Scheme of Protection and Fault Localization for All-DC Collection Network in Offshore Wind Farm
With the development of offshore wind power towards the deep and distant sea, the DC collection and DC transmission (all-DC) wind farm demonstrates distinct advantages, including the absence of the Ferranti effect and elimination of multi-level voltage conversion requirements. For the protection of the all-DC collection network in offshore wind farms, this paper first analyzes the zero-mode current relationship at line outlets of the collection network and wind turbine outlets during single-pole-to-ground (SPG) faults. Analysis reveals that (1) zero-mode current polarities are opposite between fault and non-fault lines, and (2) zero-mode current polarities are opposite between the upstream and downstream of the fault point. Based on these characteristics, a polarity comparison-based protection and fault localization scheme is proposed. The method implements waveform peak–valley detection through mathematical morphology algorithms, with detection results quantified by similarity algorithms to achieve fault section localization. An all-DC offshore wind farm simulation is built in PSCAD/EMTDC. A variety of simulations under different operating conditions are delivered, demonstrating the validity and effectiveness of the proposed protection and fault localization scheme. The method accurately distinguishes the SPG fault on lines and buses while remaining unaffected by fault resistance.
- 16 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 10109
Open AccessIntegrated Scheme of Protection and Fault Localization for All-DC Collection Network in Offshore Wind Farm
With the development of offshore wind power towards the deep and distant sea, the DC collection and DC transmission (all-DC) wind farm demonstrates distinct advantages, including the absence of the Ferranti effect and elimination of multi-level voltage conversion requirements. For the protection of the all-DC collection network in offshore wind farms, this paper first analyzes the zero-mode current relationship at line outlets of the collection network and wind turbine outlets during single-pole-to-ground (SPG) faults. Analysis reveals that (1) zero-mode current polarities are opposite between fault and non-fault lines, and (2) zero-mode current polarities are opposite between the upstream and downstream of the fault point. Based on these characteristics, a polarity comparison-based protection and fault localization scheme is proposed. The method implements waveform peak–valley detection through mathematical morphology algorithms, with detection results quantified by similarity algorithms to achieve fault section localization. An all-DC offshore wind farm simulation is built in PSCAD/EMTDC. A variety of simulations under different operating conditions are delivered, demonstrating the validity and effectiveness of the proposed protection and fault localization scheme. The method accurately distinguishes the SPG fault on lines and buses while remaining unaffected by fault resistance.
- Open Access
- 26 July 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 170
Pilot protection for transmission line of large-scale renewable energy system based on morphological similarity distance
- 26 July 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 170
Open AccessPilot protection for transmission line of large-scale renewable energy system based on morphological similarity distance
- Open Access
- 27 December 2024
- Published by Tech Science Press in Energy Engineering
- Vol. 122 (1) , 85-99
Integrated Equipment with Functions of Current Flow Control and Fault Isolation for Multiterminal DC Grids
The multi-terminal direct current (DC) grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy. Both the DC circuit breaker (DCCB) and the current flow con... | Find, read and cite all the research you need on Tech Science Press
- 27 December 2024
- Published by Tech Science Press in Energy Engineering
- Vol. 122 (1) , 85-99
Open AccessIntegrated Equipment with Functions of Current Flow Control and Fault Isolation for Multiterminal DC Grids
The multi-terminal direct current (DC) grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy. Both the DC circuit breaker (DCCB) and the current flow con... | Find, read and cite all the research you need on Tech Science Press
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 539-543
Improved Multiport Hybrid DC Circuit Breaker for Multiple Fault Isolation in Multi-Terminal DC Grid
The multiport DC circuit breaker has the advantages of low implementation cost and fast action speed, which is an ideal way to isolate the DC line fault in multiterminal DC grids. However, in extreme cases, multiple faults may occur in the multi-terminal DC grids, and the conventional multiport DC circuit breaker may not have the ability to handle them. To solve this problem, this paper proposes an improved multiport hybrid DC circuit breaker for multiple fault isolation in multi-terminal DC grids. The proposed breaker contains two main breakers, which serve as backup for each other when isolating single fault, thereby improving the operation reliability of the DC circuit breaker; and act cooperatively when isolating multiple faults. Extensive simulations show that the proposed multiport hybrid DC circuit breaker can meet the speed and selectivity requirements of the multi-terminal DC grid no matter whether single fault or multiple faults occur.
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 539-543
Improved Multiport Hybrid DC Circuit Breaker for Multiple Fault Isolation in Multi-Terminal DC Grid
The multiport DC circuit breaker has the advantages of low implementation cost and fast action speed, which is an ideal way to isolate the DC line fault in multiterminal DC grids. However, in extreme cases, multiple faults may occur in the multi-terminal DC grids, and the conventional multiport DC circuit breaker may not have the ability to handle them. To solve this problem, this paper proposes an improved multiport hybrid DC circuit breaker for multiple fault isolation in multi-terminal DC grids. The proposed breaker contains two main breakers, which serve as backup for each other when isolating single fault, thereby improving the operation reliability of the DC circuit breaker; and act cooperatively when isolating multiple faults. Extensive simulations show that the proposed multiport hybrid DC circuit breaker can meet the speed and selectivity requirements of the multi-terminal DC grid no matter whether single fault or multiple faults occur.
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 464-468
Bridge-Type Hybrid DC Circuit Breaker With Multiple Ports for Multiterminal Flexible DC Grid
The hybrid DC circuit breaker is an ideal way to selectively and quickly isolate DC line faults in flexible DC grids. However, under the current technical conditions, the cost of hybrid DC circuit breakers is extremely high, and it is difficult to meet the large-scale demand for DC circuit breakers in multiterminal flexible DC grids. To reduce the implementation costs of DC circuit breakers, a bridge-type hybrid DC circuit breaker with multiple ports is proposed in this paper. The proposed breaker can share the expensive main breaker among multiple adjacent lines to significantly reduce the total costs. Besides, a series branch of diode valve and resistor is configured to accelerate the fault interruption process. Extensive simulations are conducted to verify the effectiveness of the proposed bridgetype hybrid DC circuit breaker.
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 464-468
Bridge-Type Hybrid DC Circuit Breaker With Multiple Ports for Multiterminal Flexible DC Grid
The hybrid DC circuit breaker is an ideal way to selectively and quickly isolate DC line faults in flexible DC grids. However, under the current technical conditions, the cost of hybrid DC circuit breakers is extremely high, and it is difficult to meet the large-scale demand for DC circuit breakers in multiterminal flexible DC grids. To reduce the implementation costs of DC circuit breakers, a bridge-type hybrid DC circuit breaker with multiple ports is proposed in this paper. The proposed breaker can share the expensive main breaker among multiple adjacent lines to significantly reduce the total costs. Besides, a series branch of diode valve and resistor is configured to accelerate the fault interruption process. Extensive simulations are conducted to verify the effectiveness of the proposed bridgetype hybrid DC circuit breaker.
- 6 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (11) , 14197-14207
Thyristor-Based Multiport Hybrid DC Circuit Breaker for Multiterminal DC Grid Protection
Since the multiport hybrid dc circuit breaker (HCB) can share the expensive main breaker among multiple adjacent lines, it is considered as a more cost-efficient choice than typical HCB to isolate the dc-side fault in the large-scale multiterminal dc grid. However, the existing multiport HCBs still require a large number of fully controlled semiconductor switches (FCSSs), such as insulated gate bipolar transistors and integrated gate-commutated thyristors. Considering the high unit price and weak current turn-off capability of the FCSS, the total costs of the multiport HCBs are still high. Compared with the FCSS, the thyristor has significantly lower unit price, larger surge current withstanding capability, and higher reliability. Therefore, in this article, a thyristor-based multiport hybrid dc circuit breaker (T-MHCB) is proposed to replace the FCSS-based MHCB, which has close action speed but significantly lower costs. Extensive simulations and experiments have verified the effectiveness of the proposed T-MHCB. Besides, the performance comparison of the T-MHCB with existing solutions is elaborated.
- 6 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (11) , 14197-14207
Thyristor-Based Multiport Hybrid DC Circuit Breaker for Multiterminal DC Grid Protection
Since the multiport hybrid dc circuit breaker (HCB) can share the expensive main breaker among multiple adjacent lines, it is considered as a more cost-efficient choice than typical HCB to isolate the dc-side fault in the large-scale multiterminal dc grid. However, the existing multiport HCBs still require a large number of fully controlled semiconductor switches (FCSSs), such as insulated gate bipolar transistors and integrated gate-commutated thyristors. Considering the high unit price and weak current turn-off capability of the FCSS, the total costs of the multiport HCBs are still high. Compared with the FCSS, the thyristor has significantly lower unit price, larger surge current withstanding capability, and higher reliability. Therefore, in this article, a thyristor-based multiport hybrid dc circuit breaker (T-MHCB) is proposed to replace the FCSS-based MHCB, which has close action speed but significantly lower costs. Extensive simulations and experiments have verified the effectiveness of the proposed T-MHCB. Besides, the performance comparison of the T-MHCB with existing solutions is elaborated.
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2936-2940
Line Pilot Protection for DFIG Wind Farm Transmission Lines Based on Wasserstein Distance
When faults occur in the transmission lines of wind farms, the fault characteristics on the wind farm side exhibit significant differences from those on the AC grid side due to the control actions of the doubly-fed induction generator (DFIG) converters and crowbar protection. This leads to a substantial deterioration in the effectiveness of conventional protection methods relying on power frequency parameters, and even giving rise to occurrences of erroneous tripping. To address this issue, a pilot protection scheme based on the Wasserstein distance is proposed, taking advantage of the waveform shape differences of fault currents on both sides of the transmission lines. Extensive simulation analysis reveals that the proposed pilot protection scheme, based on the Wasserstein distance, remains unaffected by the fault location, fault type, and transitional resistance at the fault point. It reliably operates in various fault scenarios and offers a high level of sensitivity.
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2936-2940
Line Pilot Protection for DFIG Wind Farm Transmission Lines Based on Wasserstein Distance
When faults occur in the transmission lines of wind farms, the fault characteristics on the wind farm side exhibit significant differences from those on the AC grid side due to the control actions of the doubly-fed induction generator (DFIG) converters and crowbar protection. This leads to a substantial deterioration in the effectiveness of conventional protection methods relying on power frequency parameters, and even giving rise to occurrences of erroneous tripping. To address this issue, a pilot protection scheme based on the Wasserstein distance is proposed, taking advantage of the waveform shape differences of fault currents on both sides of the transmission lines. Extensive simulation analysis reveals that the proposed pilot protection scheme, based on the Wasserstein distance, remains unaffected by the fault location, fault type, and transitional resistance at the fault point. It reliably operates in various fault scenarios and offers a high level of sensitivity.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (7) , 9100-9115
A Comprehensive Review of Multiport DC Circuit Breakers for MTdc Grid Protection
Voltage source converter–based multiterminal dc (MTdc) grids, including high- and medium-voltage levels, have attracted attention in recent years and developed fast. To protect the MTdc grids selectively, the dc circuit breaker (DCCB) is identified as the best choice. However, due to the high unit price and the required large number of DCCBs in the future large-scale MTdc grids, the total investment cost is unacceptable. Besides, the large volume and weight also limit their applications. To solve these problems, a variety of multiport dc circuit breakers (MPCBs) are proposed, which achieve significantly reduced costs and footprints by component sharing and device integration. This article first introduces the classifications and the basic principles of the existing MPCBs, and furthermore summarizes their technical requirements. Then, the economic and functional analysis of each MPCB is presented, and the performance comparisons among different topologies are elaborated. Finally, the challenges and future trends of the MPCBs are discussed and the findings are concluded.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (7) , 9100-9115
A Comprehensive Review of Multiport DC Circuit Breakers for MTdc Grid Protection
Voltage source converter–based multiterminal dc (MTdc) grids, including high- and medium-voltage levels, have attracted attention in recent years and developed fast. To protect the MTdc grids selectively, the dc circuit breaker (DCCB) is identified as the best choice. However, due to the high unit price and the required large number of DCCBs in the future large-scale MTdc grids, the total investment cost is unacceptable. Besides, the large volume and weight also limit their applications. To solve these problems, a variety of multiport dc circuit breakers (MPCBs) are proposed, which achieve significantly reduced costs and footprints by component sharing and device integration. This article first introduces the classifications and the basic principles of the existing MPCBs, and furthermore summarizes their technical requirements. Then, the economic and functional analysis of each MPCB is presented, and the performance comparisons among different topologies are elaborated. Finally, the challenges and future trends of the MPCBs are discussed and the findings are concluded.
- 1 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 345-349
Research on Current Control Strategy of New Energy Photovoltaic Grid-connected Inverter
For the grid-connected process of photovoltaic power generation, the grid-connected inverter is much more important. The current control strategy plays a significant role in the normal operation of the entire inverter and the system, as well as in the coordination and cooperation with other parts. On account of this, study the operating condition of the inverter with different current control strategies is of great significance. In this article, by establishing mathematical models, control performance of inverters with different current controllers is compared, which include the PI controller, the PR controller and the QPR controller. On the one hand, through theoretical derivation, the analysis proves that comparing to the traditional PI controller and ordinary PR controller, the QPR controller can not only realize zero error tracking, but also can follow the given waveform with no static difference near the fundamental wave and the gain will not be too high, making the system more stable. On the other hand, the simulation operation in MATLAB/Simulink compares the control effect of PR controller and QPR controller, and proves that the latter has better performance.
- 1 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 345-349
Research on Current Control Strategy of New Energy Photovoltaic Grid-connected Inverter
For the grid-connected process of photovoltaic power generation, the grid-connected inverter is much more important. The current control strategy plays a significant role in the normal operation of the entire inverter and the system, as well as in the coordination and cooperation with other parts. On account of this, study the operating condition of the inverter with different current control strategies is of great significance. In this article, by establishing mathematical models, control performance of inverters with different current controllers is compared, which include the PI controller, the PR controller and the QPR controller. On the one hand, through theoretical derivation, the analysis proves that comparing to the traditional PI controller and ordinary PR controller, the QPR controller can not only realize zero error tracking, but also can follow the given waveform with no static difference near the fundamental wave and the gain will not be too high, making the system more stable. On the other hand, the simulation operation in MATLAB/Simulink compares the control effect of PR controller and QPR controller, and proves that the latter has better performance.