Dmytro Romanchenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dmytro Romanchenko has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Akram Sandvall
Energy Systems Technology, Division of Energy Technology, Department of Energy and Environment, Chalmers University of Technology, SE-412 96 Gothenburg, Sweden
1 shared publication Emil Nyholm
1 shared publication- Emil Nyholm
Department of Space, Earth and Environment, Energy Technology, Chalmers University of Technology, 412 96 Gothenburg, Sweden
1 shared publication Filip Johnsson
1 shared publication- Filip Johnsson
Chalmers University of Technology
1 shared publication - Karl Vilén
IVL - Swedish Environmental Research Institute
1 shared publication
Latest Publications
- Open Access
- 9 September 2026
- Published by Aalborg University in International Journal of Sustainable Energy Planning and Management
- Vol. 51, 67-84
Long-Term Provision of Ancillary Services for the Electricity System Using District Heating Technologies – Modeling Study for the Case of Sweden
The electricity sector is a key sector in the full energy system and is therefore crucial to consider in the transformation into a fossil-free energy system. Several ancillary services (AS) which operate at short-term scales, i.e., seconds up to multiple minutes, are implemented by the grid operators to balance the electricity system. District heating technologies, such as heat pumps (HPs) and combined heat and power (CHP), could potentially provide AS for the electricity system, thus improving the cost-efficiency of future energy systems. A long-term modeling approach using the TIMES framework is used in this study to analyze how the Swedish energy system can develop cost-efficiently when demands for energy and AS shall be fulfilled in several developed cases. The results are compared to cases without AS. The results show that DH technologies can cost-efficiently provide AS, mainly for the slowest upwards service, mFRR+. DH HPs and biomass CHP plants cover over half of the mFRR+ demand in the winter in southern Sweden, highlighting DH’s potential as a flexible resource. The results further show that new investments in DH technologies are attributed to energy demands, not AS provision, thereby indicating that AS provision does not incentivize new investments into DH technologies.
- 9 September 2026
- Published by Aalborg University in International Journal of Sustainable Energy Planning and Management
- Vol. 51, 67-84
Open AccessLong-Term Provision of Ancillary Services for the Electricity System Using District Heating Technologies – Modeling Study for the Case of Sweden
The electricity sector is a key sector in the full energy system and is therefore crucial to consider in the transformation into a fossil-free energy system. Several ancillary services (AS) which operate at short-term scales, i.e., seconds up to multiple minutes, are implemented by the grid operators to balance the electricity system. District heating technologies, such as heat pumps (HPs) and combined heat and power (CHP), could potentially provide AS for the electricity system, thus improving the cost-efficiency of future energy systems. A long-term modeling approach using the TIMES framework is used in this study to analyze how the Swedish energy system can develop cost-efficiently when demands for energy and AS shall be fulfilled in several developed cases. The results are compared to cases without AS. The results show that DH technologies can cost-efficiently provide AS, mainly for the slowest upwards service, mFRR+. DH HPs and biomass CHP plants cover over half of the mFRR+ demand in the winter in southern Sweden, highlighting DH’s potential as a flexible resource. The results further show that new investments in DH technologies are attributed to energy demands, not AS provision, thereby indicating that AS provision does not incentivize new investments into DH technologies.
- Open Access
- 1 January 2021
- Published by Elsevier in Sustainable Cities and Society
- Vol. 64
Impacts of demand response from buildings and centralized thermal energy storage on district heating systems
- 1 January 2021
- Published by Elsevier in Sustainable Cities and Society
- Vol. 64
Open AccessImpacts of demand response from buildings and centralized thermal energy storage on district heating systems
- Open Access
Flexibility Potential of Space Heating Demand Response in Buildings for District Heating Systems
Using an integrated demand-supply optimization model, this work investigates the potential for flexible space heating demand, i.e., demand response (DR), in buildings, as well as its effects on the heating demand and the operation of a district heating (DH) system. The work applies a building stock description, including both residential and non-residential buildings, and employs a representation of the current DH system of the city of Gothenburg, Sweden as a case study. The results indicate that space heating DR in buildings can have a significant impact on the cost-optimal heat supply of the city by smoothing variations in the system heat demand. DR implemented via indoor temperature deviations of as little as +1 °C can smoothen the short-term (daily) fluctuations in the system heating demand by up to 18% over a period of 1 year. The smoothening of the demand reduces the cost of heat generation, in that the heat supply and number of full-load hours of base-load heat generation units increase, while the number of starts for the peaking units decreases by more than 80%. DR through temperature deviations of +3 °C confers diminishing returns in terms of its effects on the heat demand, as compared to the DR via +1 °C.
Open AccessFlexibility Potential of Space Heating Demand Response in Buildings for District Heating Systems
Using an integrated demand-supply optimization model, this work investigates the potential for flexible space heating demand, i.e., demand response (DR), in buildings, as well as its effects on the heating demand and the operation of a district heating (DH) system. The work applies a building stock description, including both residential and non-residential buildings, and employs a representation of the current DH system of the city of Gothenburg, Sweden as a case study. The results indicate that space heating DR in buildings can have a significant impact on the cost-optimal heat supply of the city by smoothing variations in the system heat demand. DR implemented via indoor temperature deviations of as little as +1 °C can smoothen the short-term (daily) fluctuations in the system heating demand by up to 18% over a period of 1 year. The smoothening of the demand reduces the cost of heat generation, in that the heat supply and number of full-load hours of base-load heat generation units increase, while the number of starts for the peaking units decreases by more than 80%. DR through temperature deviations of +3 °C confers diminishing returns in terms of its effects on the heat demand, as compared to the DR via +1 °C.