Bestimmung des Teilsicherheitsbeiwerts für Wandscheiben aus unbewehrtem Mauerwerk
Partial safety factors for resistance applied in the design equation of semi‐probabilistic formats can be obtained from the evaluation of a test database. These partial safety factors are influenced by two factors, the material uncertainty and the model uncertainty. This topic is covered in a former publication [1]. It includes the determination of a partial factor for the model uncertainty of unreinforced masonry shear walls. In this study the authors examine the next step, and calculate the partial factor of resistance applying the same method, as recommended i n EN 1990 – Annex D. In addition to the Coefficient of Variation (COV) for the model uncertainty, the calculation of the resistance partial factor considers deviations in geometry, as well as loading and material properties. The influence of the material uncertainty on structural performance is considered in the calculation by means of a weighted average of all COV values for various types of material properties, based on the number of relevant failure modes in the test database. In the last step, the resistance partial factors for models defined in DIN EN 1996‐1‐1/NA and DIN EN 1996‐1‐1/NA – Annex K are calculated by applying the probabilistic methods recommended in EN 1990 – Annex D and the model bias.
Bestimmung des Teilsicherheitsbeiwerts für Wandscheiben aus unbewehrtem Mauerwerk
Partial safety factors for resistance applied in the design equation of semi‐probabilistic formats can be obtained from the evaluation of a test database. These partial safety factors are influenced by two factors, the material uncertainty and the model uncertainty. This topic is covered in a former publication [1]. It includes the determination of a partial factor for the model uncertainty of unreinforced masonry shear walls. In this study the authors examine the next step, and calculate the partial factor of resistance applying the same method, as recommended i n EN 1990 – Annex D. In addition to the Coefficient of Variation (COV) for the model uncertainty, the calculation of the resistance partial factor considers deviations in geometry, as well as loading and material properties. The influence of the material uncertainty on structural performance is considered in the calculation by means of a weighted average of all COV values for various types of material properties, based on the number of relevant failure modes in the test database. In the last step, the resistance partial factors for models defined in DIN EN 1996‐1‐1/NA and DIN EN 1996‐1‐1/NA – Annex K are calculated by applying the probabilistic methods recommended in EN 1990 – Annex D and the model bias.
Determination of partial factor for model uncertainty for unreinforced masonry shear walls
Experiments in structural engineering can play an important role in the prediction and characterization of the material properties and behaviour of structural components. In order to cover all aspects in tests and use the results for design purposes, several methods have been included in EN 1990 Annex D for design based on test data. The calculation of characteristic values and design values for material resistance are the main aspects. In this study, the recommended methods in Annex D of EN 1990 for resistance of the material will be used to extract the partial safety factors for masonry structures based on the formulation of design and characteristic values. A database including more than 100 tests on unreinforced masonry shear walls will be used to evaluate the results. The resistance model for shear walls based on the recommendation in the Eurocode will be compared with the test results. The main aim will be to compare the model prediction and the test results. Deviation of the prediction from the test is caused by model error or model uncertainty. The test database includes results for three types of masonry units – fired clay, calcium silicate and autoclaved aerated concrete. The evaluation of partial factors for masonry shear models will be undertaken based on the scatter and the model bias for the whole database. Further analysis will also be performed for each type of masonry unit for classification of the outcome.
Determination of partial factor for model uncertainty for unreinforced masonry shear walls
Experiments in structural engineering can play an important role in the prediction and characterization of the material properties and behaviour of structural components. In order to cover all aspects in tests and use the results for design purposes, several methods have been included in EN 1990 Annex D for design based on test data. The calculation of characteristic values and design values for material resistance are the main aspects. In this study, the recommended methods in Annex D of EN 1990 for resistance of the material will be used to extract the partial safety factors for masonry structures based on the formulation of design and characteristic values. A database including more than 100 tests on unreinforced masonry shear walls will be used to evaluate the results. The resistance model for shear walls based on the recommendation in the Eurocode will be compared with the test results. The main aim will be to compare the model prediction and the test results. Deviation of the prediction from the test is caused by model error or model uncertainty. The test database includes results for three types of masonry units – fired clay, calcium silicate and autoclaved aerated concrete. The evaluation of partial factors for masonry shear models will be undertaken based on the scatter and the model bias for the whole database. Further analysis will also be performed for each type of masonry unit for classification of the outcome.