Gerson Kniphoff da Cruz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Gerson Kniphoff da Cruz has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Andressa Novatski
Departamento de Fisica, Universidade Estadual de Ponta Grossa, Ponta Grossa 84030-900, PR, Brazil
3 shared publications - Aloisi Somer
Departamento de Física, Universidade Estadual de Ponta Grossa, Ponta Grossa, Brazil
2 shared publications Cláudia Bonardi
Universidade Estadual de Ponta Grossa, Brasil
2 shared publications- Alessandra Reis
Department of Restorative Dentistry State University of Ponta Grossa Ponta Grossa Paraná Brazil
1 shared publication Alessandro Dourado Loguércio
Department of Restorative Dentistry, State University of Ponta Grossa 3 , PR, Brazil
1 shared publicationAloisi Somer
1 shared publication
Latest Publications
- 10 August 2022
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 43 (10) , 1-26
The Influence of the Surface Micro-structure Change on the Stainless Steel Effective Thermal Diffusivity
- 10 August 2022
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 43 (10) , 1-26
The Influence of the Surface Micro-structure Change on the Stainless Steel Effective Thermal Diffusivity
- Open Access
- 7 January 2022
- Published by Springer Nature in Research Square
The bows and rings of dawn and dusk
The arcs of dawn and dusk are natural phenomena that define the boundary of the border between day and night. They are associated with the refraction of solar rays at high angles of incidence that converge to project an arc of light onto the back side of the earth's atmosphere. The rings of dawn and dusk, in turn, are associated with rays, also at large angles of incidence, which converge to project the image of the Sun. Arcs and rings become visible by scattering light by clouds or particles suspended in atmospheric air in the region in which they occur. Here we show a model that describes these natural phenomena and report the first-time record image produced in July of this year.
- 7 January 2022
- Published by Springer Nature in Research Square
Open AccessThe bows and rings of dawn and dusk
The arcs of dawn and dusk are natural phenomena that define the boundary of the border between day and night. They are associated with the refraction of solar rays at high angles of incidence that converge to project an arc of light onto the back side of the earth's atmosphere. The rings of dawn and dusk, in turn, are associated with rays, also at large angles of incidence, which converge to project the image of the Sun. Arcs and rings become visible by scattering light by clouds or particles suspended in atmospheric air in the region in which they occur. Here we show a model that describes these natural phenomena and report the first-time record image produced in July of this year.
- Open Access
- 19 February 2018
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Ensino de Física
- Vol. 40 (3)
Um iluminador de baixo custo para a realização de experimentos de óptica geométrica
Resumo Uma justificativa apresentada para a pouca utilização dos experimentos de óptica geométrica nas escolas brasileiras é o elevado custo dos equipamentos necessários para tais estudos. Neste trabalho, descrevemos um iluminador de LEDs de baixo custo que apresenta uma alta performance quando comparado com os iluminadores comerciais para o estudo de lentes esféricas. Associando-se ao iluminador a lente de uma lupa, que pode ser adquirida em loja de materiais de escritório, é possível a conceituação completa da óptica geométrica de lentes esféricas. Como características do novo equipamento, ressalta-se a possibilidade de utilizá-lo em ambientes iluminados, a facilidade no estudo das caracterizações de imagens formadas em sistemas ópticos e a possibilidade de simulação de uma situação real de formação de uma imagem por uma lente. No trabalho, também são apresentados e discutidos exemplos de aplicações do iluminador. Experimentos básicos e fundamentais da óptica geométrica de lentes esféricas são colocados em evidência com este novo equipamento.
- 19 February 2018
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Ensino de Física
- Vol. 40 (3)
Open AccessUm iluminador de baixo custo para a realização de experimentos de óptica geométrica
Resumo Uma justificativa apresentada para a pouca utilização dos experimentos de óptica geométrica nas escolas brasileiras é o elevado custo dos equipamentos necessários para tais estudos. Neste trabalho, descrevemos um iluminador de LEDs de baixo custo que apresenta uma alta performance quando comparado com os iluminadores comerciais para o estudo de lentes esféricas. Associando-se ao iluminador a lente de uma lupa, que pode ser adquirida em loja de materiais de escritório, é possível a conceituação completa da óptica geométrica de lentes esféricas. Como características do novo equipamento, ressalta-se a possibilidade de utilizá-lo em ambientes iluminados, a facilidade no estudo das caracterizações de imagens formadas em sistemas ópticos e a possibilidade de simulação de uma situação real de formação de uma imagem por uma lente. No trabalho, também são apresentados e discutidos exemplos de aplicações do iluminador. Experimentos básicos e fundamentais da óptica geométrica de lentes esféricas são colocados em evidência com este novo equipamento.
- Open Access
- 1 February 2018
- Published by AIP Publishing in AIP Advances
- Vol. 8 (2) , 025225
Investigating the real translucency of the endodontic fiber posts
Researchers have been investigating the light intensity scattered by a translucent fiber post with application in dentistry by different methods. In this work, we introduce a new system capable to record a light scattered profile, step-by-step, as a function of the length of the translucent fiber post. To support our studies, an extensive characterization of the system was carried out and this is presented and discussed here. The system was implemented using the phase sensitive detection. The equipment measures the light scattered without the need of any preparing parts and the fiber post is fixed directly in the fiber post holder becoming ready for measurement. Measures can be recorded with a spatial resolution smaller than 0.01 mm throughout the length of the fiber post being investigated. The system was implemented by using a photomultiplier tube that improves sensitivity for the optical detection. The recorded result is a signal directly proportional to the scattered light and it allows us to obtain a normalized profile that can be used as a map of the scattered light of the fiber post in study. Furthermore, we are able to demonstrate a low intensity of light in the tip region of the fiber post, along with the dependency of the light attenuation with the fiber post body volume and shape. This new system will certainly contribute to achieve better results in fiber post designing and in restoration of endodontic treated teeth because it provides a more well-founded choice of the fiber post to be used, and of the time of exposure to the curing light.
- 1 February 2018
- Published by AIP Publishing in AIP Advances
- Vol. 8 (2) , 025225
Open AccessInvestigating the real translucency of the endodontic fiber posts
Researchers have been investigating the light intensity scattered by a translucent fiber post with application in dentistry by different methods. In this work, we introduce a new system capable to record a light scattered profile, step-by-step, as a function of the length of the translucent fiber post. To support our studies, an extensive characterization of the system was carried out and this is presented and discussed here. The system was implemented using the phase sensitive detection. The equipment measures the light scattered without the need of any preparing parts and the fiber post is fixed directly in the fiber post holder becoming ready for measurement. Measures can be recorded with a spatial resolution smaller than 0.01 mm throughout the length of the fiber post being investigated. The system was implemented by using a photomultiplier tube that improves sensitivity for the optical detection. The recorded result is a signal directly proportional to the scattered light and it allows us to obtain a normalized profile that can be used as a map of the scattered light of the fiber post in study. Furthermore, we are able to demonstrate a low intensity of light in the tip region of the fiber post, along with the dependency of the light attenuation with the fiber post body volume and shape. This new system will certainly contribute to achieve better results in fiber post designing and in restoration of endodontic treated teeth because it provides a more well-founded choice of the fiber post to be used, and of the time of exposure to the curing light.
- Open Access
- 15 December 2017
- Published by Instituto Internacional de Analise Termica in Brazilian Journal of Thermal Analysis
- Vol. 6 (4)
Efeito da adição de BaO nas propriedades térmicas e estruturais do sistema vítreo TeO2-Li2O-BaO
- 15 December 2017
- Published by Instituto Internacional de Analise Termica in Brazilian Journal of Thermal Analysis
- Vol. 6 (4)
Open AccessEfeito da adição de BaO nas propriedades térmicas e estruturais do sistema vítreo TeO2-Li2O-BaO
- 1 April 2015
- Vol. 17 (2) , 181-188
Influence of Delivered Radiant Exposure Values on Bonding of Fiber Posts to Root Canals
To evaluate the effect of different radiant exposure values delivered to two simplified etch-and-rinse adhesive systems on push-out bond strength (PBS) of fiber posts to root canal, as well as nanoleakage (NL) and in situ degree of conversion (DC) within the hybrid layer.The roots of human premolars were endodontically prepared and divided into 6 groups according to the combination of the main factors adhesive/resin cement (2 commercial brands) and radiant exposure (4, 16, 48, and 288 J/cm2). The posts were cemented and the PBS tested at 0.5 mm/min (n = 7). The NL (n = 3) was evaluated using SEM after immersion of specimens in 50% silver nitrate. Micro-Raman spectroscopy was performed to determine the in situ DC (n = 2). Data were analyzed by three-way repeated measures ANOVA and Tukey's post-hoc test (5%).PBS (MPa) showed a significant difference only for the middle third when an increase in radiant exposure from 4 to 16 J/cm2 or higher was used (p < 0.05). The NL (%) decreased significantly with increasing radiant exposure from 48 to 288 J/cm2 in the middle and apical thirds when compared to lower radiant exposure (p < 0.05). The radiant exposure of 288 J/cm2 significantly increased the DC (%) in the middle and apical thirds, compared the other radiant exposure values (p < 0.05).The increase in radiant exposure delivered to the cervical third of root canals during post cementation improved the adhesive performance of simplified etch-and-rinse adhesive systems in the apical and middle thirds.
- 1 April 2015
- Vol. 17 (2) , 181-188
Influence of Delivered Radiant Exposure Values on Bonding of Fiber Posts to Root Canals
To evaluate the effect of different radiant exposure values delivered to two simplified etch-and-rinse adhesive systems on push-out bond strength (PBS) of fiber posts to root canal, as well as nanoleakage (NL) and in situ degree of conversion (DC) within the hybrid layer.The roots of human premolars were endodontically prepared and divided into 6 groups according to the combination of the main factors adhesive/resin cement (2 commercial brands) and radiant exposure (4, 16, 48, and 288 J/cm2). The posts were cemented and the PBS tested at 0.5 mm/min (n = 7). The NL (n = 3) was evaluated using SEM after immersion of specimens in 50% silver nitrate. Micro-Raman spectroscopy was performed to determine the in situ DC (n = 2). Data were analyzed by three-way repeated measures ANOVA and Tukey's post-hoc test (5%).PBS (MPa) showed a significant difference only for the middle third when an increase in radiant exposure from 4 to 16 J/cm2 or higher was used (p < 0.05). The NL (%) decreased significantly with increasing radiant exposure from 48 to 288 J/cm2 in the middle and apical thirds when compared to lower radiant exposure (p < 0.05). The radiant exposure of 288 J/cm2 significantly increased the DC (%) in the middle and apical thirds, compared the other radiant exposure values (p < 0.05).The increase in radiant exposure delivered to the cervical third of root canals during post cementation improved the adhesive performance of simplified etch-and-rinse adhesive systems in the apical and middle thirds.