Edouard Huard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Edouard Huard has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Jérôme Primot
Off Natl Etud & Rech Aerosp, ONERA, F-91120 Palaiseau, France
3 shared publicationsSophie Derelle
Off Natl Etud & Rech Aerosp, ONERA, F-91120 Palaiseau, France
3 shared publicationsOlivier Gravrand
Commissariat à l’Énergie Atomique et aux énergies Alternatives - Laboratoire d’Électronique et de Technologie de l’Information
2 shared publicationsJean Nghiem
Office National d’Etudes et de Recherches Aérospatiales, Chemin de la Hunière, 91123 Palaiseau, France
1 shared publicationJoris Gorée
Off Natl Etud & Rech Aerosp, ONERA, F-91120 Palaiseau, France
1 shared publicationJulien Jaeck
ONERA/DOTA – Chemin de la Vauve aux Granges, Palaiseau, France
1 shared publication
Latest Publications
- 8 August 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (17) , 30609-30621
Absolute evaluation of the optical transfer function of the high aperture infrared cryogenic objective
The field of infrared detectors is experiencing a strong movement towards smaller pixel pitches, and it is now common to see pitches close to the wavelength. This raises major problems in measuring their characteristics, especially their transfer function. The latter can be measured by optical pattern projection methods using a low F/# objective, such as the spot scan method. However, in order to obtain the quantitative transfer function measurement of detectors, the objective spatial response should be measured and deconvoluted precisely, since the size of the focused optical spot is close to the pixel pitch. Therefore, the purpose of this paper is to propose a protocol that performs an absolute measurement of a high-quality infrared objective. The main idea of the article is to link the measurement standard to a fundamental theory, the Huygens-Fresnel principle, using a particular wavefront sensor as a secondary measurement standard. This has various metrological advantages, that allow the uncertainties of the optical transfer function measurement to be controlled and evaluated. The protocol and the propagation of errors described in the article are both used to demonstrate the value of this approach.
- 8 August 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (17) , 30609-30621
Absolute evaluation of the optical transfer function of the high aperture infrared cryogenic objective
The field of infrared detectors is experiencing a strong movement towards smaller pixel pitches, and it is now common to see pitches close to the wavelength. This raises major problems in measuring their characteristics, especially their transfer function. The latter can be measured by optical pattern projection methods using a low F/# objective, such as the spot scan method. However, in order to obtain the quantitative transfer function measurement of detectors, the objective spatial response should be measured and deconvoluted precisely, since the size of the focused optical spot is close to the pixel pitch. Therefore, the purpose of this paper is to propose a protocol that performs an absolute measurement of a high-quality infrared objective. The main idea of the article is to link the measurement standard to a fundamental theory, the Huygens-Fresnel principle, using a particular wavefront sensor as a secondary measurement standard. This has various metrological advantages, that allow the uncertainties of the optical transfer function measurement to be controlled and evaluated. The protocol and the propagation of errors described in the article are both used to demonstrate the value of this approach.
- 25 August 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (11) , 6957-6962
Development of a Cryogenic Test Bench for Spectral MTF Measurement on Midwave Infrared Focal Plane Arrays
- 25 August 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (11) , 6957-6962
Development of a Cryogenic Test Bench for Spectral MTF Measurement on Midwave Infrared Focal Plane Arrays
- 21 February 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (5) , 5200-5211
Multi-frame linear regressive filter for the measurement of infrared pixel spatial response and MTF from sparse data
A challenging point in the prediction of the image quality of infrared imaging systems is the evaluation of the detector modulation transfer function (MTF). In this paper, we present a linear method to get a 2D continuous MTF from sparse spectral data. Within the method, an object with a predictable sparse spatial spectrum is imaged by the focal plane array. The sparse data is then treated to return the 2D continuous MTF with the hypothesis that all the pixels have an identical spatial response. The linearity of the treatment is a key point to estimate directly the error bars of the resulting detector MTF. The test bench will be presented along with measurement tests on a 25 μm pitch InGaAs detector.
- 21 February 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (5) , 5200-5211
Multi-frame linear regressive filter for the measurement of infrared pixel spatial response and MTF from sparse data
A challenging point in the prediction of the image quality of infrared imaging systems is the evaluation of the detector modulation transfer function (MTF). In this paper, we present a linear method to get a 2D continuous MTF from sparse spectral data. Within the method, an object with a predictable sparse spatial spectrum is imaged by the focal plane array. The sparse data is then treated to return the 2D continuous MTF with the hypothesis that all the pixels have an identical spatial response. The linearity of the treatment is a key point to estimate directly the error bars of the resulting detector MTF. The test bench will be presented along with measurement tests on a 25 μm pitch InGaAs detector.