THTerutake Hayashi

Terutake Hayashi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Terutake Hayashi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Photocatalytic Nanofabrication and Intracellular Raman Imaging of Living Cells with Functionalized AFM Probes

    by Takayuki Shibata, Hiromi Furukawa, Yasuharu Ito, Masahiro Nagahama, Terutake Hayashi, Miho Ishii-Teshima, Moeto Nagai

    Atomic force microscopy (AFM) is an effective platform for in vitro manipulation and analysis of living cells in medical and biological sciences. To introduce additional new features and functionalities into a conventional AFM system, we investigated the photocatalytic nanofabrication and intracellular Raman imaging of living cells by employing functionalized AFM probes. Herein, we investigated the effect of indentation speed on the cell membrane perforation of living HeLa cells based on highly localized photochemical oxidation with a catalytic titanium dioxide (TiO2)-functionalized AFM probe. On the basis of force–distance curves obtained during the indentation process, the probability of cell membrane perforation, penetration force, and cell viability was determined quantitatively. Moreover, we explored the possibility of intracellular tip-enhanced Raman spectroscopy (TERS) imaging of molecular dynamics in living cells via an AFM probe functionalized with silver nanoparticles in a homemade Raman system integrated with an inverted microscope. We successfully demonstrated that the intracellular TERS imaging has the potential to visualize distinctly different features in Raman spectra between the nucleus and the cytoplasm of a single living cell and to analyze the dynamic behavior of biomolecules inside a living cell.


  • Open Access

    Nanoparticle sizing for poly-dispersed particles using Nanoparticle chip

    by Jiaqing Zhu, Terutake Hayashi, Syuhei Kurokawa

    For poly-dispersed nanoparticles, which have more than two peaks on their particle size distribution (PSD), it is important to determine the mean particle diameter and their dispersion at each peak in a liquid. Dynamic Light Scattering (DLS), that is one of a typical nanoparticle sizing method, has difficulty to determine the several peaks in the PSD for the poly-dispersed particles. On the other hand, Image analysis methods (IA) can distinguish the peak for both the primary particle and secondary particle in the PSD of poly-dispersed particles accurately. However, IA is a time-consuming method and it is difficult to apply the measurement of the PSD due to the requirement of measuring the large number of particles, one by one. The particles in the liquid are transferred to a substrate in air when observing the particle to measure their size and the size distribution. In this procedure, some particles usually aggregate with surrounding particles. It causes the difference between the PSD for dispersed particles in liquid and that of the particles on the substrate. In this study, we suggest a novel particle sizing method using “Nanoparticle chip”, that is nanoparticles grid on the substrate to maintain the poly-dispersed condition in the liquid, to develop IA for measuring the poly-dispersed particles in liquid. The dispersed condition of the particle on Nanoparticle chip can be kept from the condition in liquid when the particles are transferred to the substrate in air. Therefore, measuring the PSD on Nanoparticle chip is equal to measure the PSD in the liquid. In this paper, in order to verify the feasibility of the nanoparticle sizing using Nanoparticle chip to measure the PSD for poly-dispersed particles in the liquid, we performed a fundamental experiment to fabricate the Nanoparticle chip and to determine the PSD for poly-dispersed particles. In this report, it is reported that the PSD for the poly-dispersed particles, which is the mixture of 152nm particle and 498nm particle, using Nanoparticle chip.


  • Investigation of Surface Excitation Effect for Ablation of 4H-SiC Substrate Using Double-Pulse Beam

    by K. Matsunaga, T. Hayashi, S. Kurokawa, H. Yokoo, N. Hasegawa, M. Nishikino, T. Kumada, T. Otobe, Y. Matsukawa, Y. Takaya

  • Evaluation of optical heterogeneity using phase-shift digital holography

    by Terutake Hayashi, Masaki Michihata, Yasuhiro Takaya

    In order to achieve high-precision non-destructive evaluation of optical heterogeneity, we develop a parallel phase-shift digital holography system, which enables measurements of the optical path differences at a nanometer-scale resolution. The amplitude and phase distributions of the object wave can be reconstructed directly from a single hologram by using the parallel phase-shift digital holography system. The system can be applied to evaluate the glass plate samples and the glass with the shape of an axially symmetric converging lens. We perform the fundamental experiment to measure the phase profile of the object wave which passing though the optical flat and plano-convex lens in order to evaluate the optical homogeneity of the sample.

  • Profile measurement using standing wave trapping

    by Taisuke Washitani, Masaki Michihata, Terutake Hayashi, Yasuhiro Takaya

    Various products have been miniaturized in recent years. And, the measurement technology for surface profile of micro components is highly demanded. Then, we proposed a new measurement technique for surface profile using the standing wave trapping. The high-accuracy scale and the high-sensitive sensor are required in the profile measurement. In our measurement system, the optical trapping particle is used as the sensor. The standing wave pattern is used as the measurement scale, which has wavelength-determined intensity pitch of interference field (λ/2). Therefore, this measurement technique is expected to perform the high-accuracy measurement. It was experimentally found that the vertical measurement range is about 250 μm. The uncertainty of the sensor is ±λ/100. Thus, this technique is capable of measuring large objects in height. When measuring the continuous surface, the sensor particle is scanned in the horizontal direction above the measured surface. The trapped sensor particle in the standing wave field axially moves to follow the measured surface topography. The particle jumps when the surface profile exceeds the pitch of the standing wave pattern. Therefore, the surface profile can be calculated based on the measurement of the particle motional variation. As pre-measurement, the dependency of the scale pitch on measured surface angles was investigated. A microlens was measured with the angle dependency correction. This shows the improvement of the measurement accuracy.


  • Open Access

    LCD Microstereolithography of Photosensitive Resin with Functional Particles

    by Terutake Hayashi, Yasuhiro Takaya, Dongkeon Lee

    A novel microstereolithography (µ-STL) process has been developed in order to fabricate microparts using photosensitive resin with functional particles containing microparticles or nanoparticles. The reduction in the surplus growth, which is caused by light scattered by the filler particles in the photosensitive resin, is accomplished by using grey-scale exposure with a liquid crystal display (LCD) mask. A fabrication process that uses photosensitive resins reinforced with ceramic nanoparticles is developed. Micro bevel gears with a diameter of 1.6 mm and a tooth width of 180 µ m are fabricated. Next, the fabrication process of the electrically conductive parts is examined using a photosensitive resin that contains microsized silver particle as electrically conductive fillers. Micro-resistance patterns are fabricated to evaluate the electrical conductivity of the micro part. Annealing is then conducted for the removal of the photosensitive resin at a temperature of 350±10°C for 1 h. At a filler content of 50 wt%, the electrical resistance is as small as 3×105 W Ω•cm. Using a four-level grey-scale mask, 100 microelectrodes are fabricated simultaneously.