Daniela Claessens
Daniela Claessens has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Alexander K. Schuster
Augenklinik, Universitätsmedizin Mainz, Deutschland
2 shared publicationsRonald V. Krüger
Development, app4eyes GmbH & Co KG, Düsseldorf, Deutschland
2 shared publicationsBernd Kirchhof
Abteilung für Netzhaut- und Glaskörper-Chirurgie, Zentrum für Augenheilkunde, Universität zu Köln, Deutschland
1 shared publicationH. Beckers
Arbeits- und Verkehrsmedizin, Delmenhorster Str. 1, 50735, Köln, Deutschland
1 shared publicationKlaudia Huber-Van der Velden
Gemeinschaftspraxis Augenheilkunde Lindenthal, Köln, Deutschland
1 shared publicationLaila Singh
Max-Planck-Institut für Biologie des Alterns, Köln, Deutschland
1 shared publication
Latest Publications
- 16 August 2023
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 242 (03) , 250-252
Pupillenfunktionsstörung, Anisokorie und Irisdepigmentierung im Anschluss an COVID-19
Als Ursache neuroophthalmologischer Symptome im Zusammenhang mit einer SARS-CoV-2-Infektion werden eine zentralnervöse Beteiligung, ein Endothelschaden oder postentzündliche neurotoxische Effekte diskutiert [1]. Wir stellen den Fall einer Patientin mit einer Pupillenfunktionsstörung vor, die im Anschluss an eine COVID-19-Erkrankung beobachtet wurde. Received: 30 January 2023 Accepted: 06 June 2023 Article published online: 16 August 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 16 August 2023
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 242 (03) , 250-252
Pupillenfunktionsstörung, Anisokorie und Irisdepigmentierung im Anschluss an COVID-19
Als Ursache neuroophthalmologischer Symptome im Zusammenhang mit einer SARS-CoV-2-Infektion werden eine zentralnervöse Beteiligung, ein Endothelschaden oder postentzündliche neurotoxische Effekte diskutiert [1]. Wir stellen den Fall einer Patientin mit einer Pupillenfunktionsstörung vor, die im Anschluss an eine COVID-19-Erkrankung beobachtet wurde. Received: 30 January 2023 Accepted: 06 June 2023 Article published online: 16 August 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2022
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 240 (09) , 1091-1097
Veränderung von Teilaspekten der sehbezogenen Lebensqualität nach 3-monatiger Verwendung einer App zur Kategorisierung von Metamorphopsien
Hintergrund Verzerrtes Sehen (Metamorphopsie) ist ein Leitsymptom bei Netzhauterkrankungen und kann mit der App MacuFix kategorisiert werden. Die App zeigt auf einem Bildschirm wiederholt Szenen, die aus 4 quadratischen Feldern mit einem Gittermuster aus horizontalen und vertikalen weißen Linien auf schwarzem Hintergrund bestehen. Eines der 4 Felder unterscheidet sich durch stärker verzerrte Linien von den übrigen 3 Feldern und soll bei monokularer Betrachtung ausgewählt werden. Diese Auswahl wird wiederholt getroffen, bis ein Algorithmus den kleinsten vom Auge korrekt detektierten Verzerrungsunterschied ermittelt hat. In dieser prospektiven, kontrollierten Pilotstudie wurde untersucht, welchen Einfluss der Einsatz der App MacuFix im Vergleich zur Anwendung des Amsler-Gitters auf die sehbezogene Lebensqualität hatte. Patienten/Material und Methoden 45 Patienten, bei denen ein- oder beidseits Metamorphopsien bestanden, wurden für die Studie rekrutiert. Die sehbezogene Lebensqualität vor und nach einer 3-monatigen optionalen Anwendung der App MacuFix als Heimtest bzw. des Amsler-Gitters wurde durch Anwendung des Fragebogens National Eye Institute Visual Function Questionnaire-25 verglichen. Ergebnisse 45 Teilnehmer (18 Frauen, 27 Männer) waren im Durchschnitt 68 Jahre alt (SD ± 9,7) und hatten eine mittlere bestkorrigierte Sehschärfe von 0,6 (SD ± 0,25). Von 90 Augen wiesen 18 keine Makulopathie auf. Eine altersbedingte Makuladegeneration bestand in 52 Augen, eine epiretinale Gliose in 6, ein Makulaforamen in 1 Auge. Ein Makulaödem lag bei 2 Augen aufgrund von Diabetes, bei 4 Augen aufgrund von Uveitis, bei 1 Auge nach retinaler Venenthrombose, bei 4 Augen aufgrund eines Irvine-Gass-Syndroms und bei 2 Augen aufgrund einer Retinopathia centralis serosa vor. Nach 3 Monaten nutzten 35 Personen die App als Heimtest, 8 Personen setzten das Amsler-Gitter ein und 2 verwendeten keinen Test. Die App-Nutzer zeigten eine hochsignifikante Verbesserung der sehbezogenen Lebensqualität bei Fragen zur psychischen Gesundheit und zu Sorgen um die Sehkraft sowie eine signifikante Verbesserung in Bezug auf Leistung, Niedergeschlagenheit, Kontrolle und peinliche Situationen. Schlussfolgerung Der Einsatz der App MacuFix kann möglicherweise Teilaspekte der sehbezogenen Lebensqualität verbessern. Received: 18 December 2021 Accepted: 23 February 2022 Publication Date: 14 April 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2022
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 240 (09) , 1091-1097
Veränderung von Teilaspekten der sehbezogenen Lebensqualität nach 3-monatiger Verwendung einer App zur Kategorisierung von Metamorphopsien
Hintergrund Verzerrtes Sehen (Metamorphopsie) ist ein Leitsymptom bei Netzhauterkrankungen und kann mit der App MacuFix kategorisiert werden. Die App zeigt auf einem Bildschirm wiederholt Szenen, die aus 4 quadratischen Feldern mit einem Gittermuster aus horizontalen und vertikalen weißen Linien auf schwarzem Hintergrund bestehen. Eines der 4 Felder unterscheidet sich durch stärker verzerrte Linien von den übrigen 3 Feldern und soll bei monokularer Betrachtung ausgewählt werden. Diese Auswahl wird wiederholt getroffen, bis ein Algorithmus den kleinsten vom Auge korrekt detektierten Verzerrungsunterschied ermittelt hat. In dieser prospektiven, kontrollierten Pilotstudie wurde untersucht, welchen Einfluss der Einsatz der App MacuFix im Vergleich zur Anwendung des Amsler-Gitters auf die sehbezogene Lebensqualität hatte. Patienten/Material und Methoden 45 Patienten, bei denen ein- oder beidseits Metamorphopsien bestanden, wurden für die Studie rekrutiert. Die sehbezogene Lebensqualität vor und nach einer 3-monatigen optionalen Anwendung der App MacuFix als Heimtest bzw. des Amsler-Gitters wurde durch Anwendung des Fragebogens National Eye Institute Visual Function Questionnaire-25 verglichen. Ergebnisse 45 Teilnehmer (18 Frauen, 27 Männer) waren im Durchschnitt 68 Jahre alt (SD ± 9,7) und hatten eine mittlere bestkorrigierte Sehschärfe von 0,6 (SD ± 0,25). Von 90 Augen wiesen 18 keine Makulopathie auf. Eine altersbedingte Makuladegeneration bestand in 52 Augen, eine epiretinale Gliose in 6, ein Makulaforamen in 1 Auge. Ein Makulaödem lag bei 2 Augen aufgrund von Diabetes, bei 4 Augen aufgrund von Uveitis, bei 1 Auge nach retinaler Venenthrombose, bei 4 Augen aufgrund eines Irvine-Gass-Syndroms und bei 2 Augen aufgrund einer Retinopathia centralis serosa vor. Nach 3 Monaten nutzten 35 Personen die App als Heimtest, 8 Personen setzten das Amsler-Gitter ein und 2 verwendeten keinen Test. Die App-Nutzer zeigten eine hochsignifikante Verbesserung der sehbezogenen Lebensqualität bei Fragen zur psychischen Gesundheit und zu Sorgen um die Sehkraft sowie eine signifikante Verbesserung in Bezug auf Leistung, Niedergeschlagenheit, Kontrolle und peinliche Situationen. Schlussfolgerung Der Einsatz der App MacuFix kann möglicherweise Teilaspekte der sehbezogenen Lebensqualität verbessern. Received: 18 December 2021 Accepted: 23 February 2022 Publication Date: 14 April 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 22 August 2021
- Published by Springer Nature in International Ophthalmology
- Vol. 42 (1) , 229-238
MacuFix® versus Amsler grid for metamorphopsia categorization for macular diseases
Purpose Macular diseases often lead to metamorphopsia, which is traditionally tested using the Amsler grid. This study evaluates a novel method for assessing metamorphopsia, based on the software AMD-A Metamorphopsia Detector, application MacuFix®. Methods In this observational study, the usability of a new smartphone-based testing method to assess metamorphopsia was evaluated in 45 patients experiencing metamorphopsia in at least one eye using the questionnaire “System Usability Score (SUS).” Additionally, the diagnostic adherence of self-monitoring with the Amsler grid was compared to self-monitoring with the novel software MacuFix®. Results The average score of the SUS questionnaire in this study was 76.7 ± 15.5, corresponding to the “good” score on the grading scale. The average interval between two home administered tests was significantly shorter (6 days) when the application was used as compared to using the Amsler grid (19 days). The odds ratio of the frequency of patients using the application to the patients using the home test was 4. Conclusion MacuFix® application can help in effective home monitoring of macular function as high user satisfaction and increased testing frequency was observed in its use in patients with macular diseases.
- 22 August 2021
- Published by Springer Nature in International Ophthalmology
- Vol. 42 (1) , 229-238
MacuFix® versus Amsler grid for metamorphopsia categorization for macular diseases
Purpose Macular diseases often lead to metamorphopsia, which is traditionally tested using the Amsler grid. This study evaluates a novel method for assessing metamorphopsia, based on the software AMD-A Metamorphopsia Detector, application MacuFix®. Methods In this observational study, the usability of a new smartphone-based testing method to assess metamorphopsia was evaluated in 45 patients experiencing metamorphopsia in at least one eye using the questionnaire “System Usability Score (SUS).” Additionally, the diagnostic adherence of self-monitoring with the Amsler grid was compared to self-monitoring with the novel software MacuFix®. Results The average score of the SUS questionnaire in this study was 76.7 ± 15.5, corresponding to the “good” score on the grading scale. The average interval between two home administered tests was significantly shorter (6 days) when the application was used as compared to using the Amsler grid (19 days). The odds ratio of the frequency of patients using the application to the patients using the home test was 4. Conclusion MacuFix® application can help in effective home monitoring of macular function as high user satisfaction and increased testing frequency was observed in its use in patients with macular diseases.
- 7 December 2020
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 238 (06) , 703-710
Test-Retest-Reliability of Computer-Based Metamorphopsia Measurement in Macular Diseases
In this study, the test-retest-reliability as one aspect of reliability of metamorphopsia measurements using a computer-based measuring method was determined in patients with macular diseases. Metamorphopsia amplitude, position, and area were quantified using AMD – A Metamorphopsia Detector software (app4eyes GmbH & Co. KG, Germany) in patients with diabetic, myopic, or uveitic macular edema, intermediate or neovascular age-associated macular degeneration, epiretinal membrane, vitelliform maculopathy, Irvine-Gass syndrome, or macular edema due to venous retinal occlusion. The intraclass correlation coefficient (ICC) was calculated in order to determine the repeatability of two repeated measurements and was used as an indicator of the reliability of the measurements. In this study, metamorphopsia measurements were conducted on 36 eyes with macular diseases. Metamorphopsia measurements made using AMD – A Metamorphopsia Detector software were highly reliable and repeatable in patients with maculopathies. The intraclass correlation coefficient of all indices was excellent (0.95 – 0.97). For diseases of the vitreoretinal interface or macular diseases with intra- or subretinal edema, this metamorphopsia measurement represents a supplement for visual function testing in the clinic, as well as in clinical studies.
- 7 December 2020
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 238 (06) , 703-710
Test-Retest-Reliability of Computer-Based Metamorphopsia Measurement in Macular Diseases
In this study, the test-retest-reliability as one aspect of reliability of metamorphopsia measurements using a computer-based measuring method was determined in patients with macular diseases. Metamorphopsia amplitude, position, and area were quantified using AMD – A Metamorphopsia Detector software (app4eyes GmbH & Co. KG, Germany) in patients with diabetic, myopic, or uveitic macular edema, intermediate or neovascular age-associated macular degeneration, epiretinal membrane, vitelliform maculopathy, Irvine-Gass syndrome, or macular edema due to venous retinal occlusion. The intraclass correlation coefficient (ICC) was calculated in order to determine the repeatability of two repeated measurements and was used as an indicator of the reliability of the measurements. In this study, metamorphopsia measurements were conducted on 36 eyes with macular diseases. Metamorphopsia measurements made using AMD – A Metamorphopsia Detector software were highly reliable and repeatable in patients with maculopathies. The intraclass correlation coefficient of all indices was excellent (0.95 – 0.97). For diseases of the vitreoretinal interface or macular diseases with intra- or subretinal edema, this metamorphopsia measurement represents a supplement for visual function testing in the clinic, as well as in clinical studies.
- 26 April 2019
- Published by Springer Nature in Der Ophthalmologe
- Vol. 117 (1) , 66-68
Blaugraue Verfärbung von Haut und Bindehaut
Kolloidales Silber kann als Suspension zu (alternativ) therapeutischen Zwecken oder im Rahmen beruflicher Tätigkeiten aufgenommen und zur irreversiblen Ablagerung von Silber in Haut (typische blaugraue Verfärbung), Schleimhaut, Hornhaut, Netzhaut und inneren Organen führen. Derart entstandene Ablagerungen der Bindehaut sind differenzialdiagnostisch z. B. von einem Bindehautmelanom abzugrenzen. Colloidal silver used as a suspension for (alternative) therapeutic purposes or silver exposure due to environmental or working conditions can lead to irreversible deposits of silver granules in the skin (bluish-gray hue of the skin), mucosa, cornea, retina and internal organs. Silver-induced discoloration of the conjunctiva should therefore be taken into account when a bluish-gray discoloration raises the suspicion of conjunctival melanoma.
- 26 April 2019
- Published by Springer Nature in Der Ophthalmologe
- Vol. 117 (1) , 66-68
Blaugraue Verfärbung von Haut und Bindehaut
Kolloidales Silber kann als Suspension zu (alternativ) therapeutischen Zwecken oder im Rahmen beruflicher Tätigkeiten aufgenommen und zur irreversiblen Ablagerung von Silber in Haut (typische blaugraue Verfärbung), Schleimhaut, Hornhaut, Netzhaut und inneren Organen führen. Derart entstandene Ablagerungen der Bindehaut sind differenzialdiagnostisch z. B. von einem Bindehautmelanom abzugrenzen. Colloidal silver used as a suspension for (alternative) therapeutic purposes or silver exposure due to environmental or working conditions can lead to irreversible deposits of silver granules in the skin (bluish-gray hue of the skin), mucosa, cornea, retina and internal organs. Silver-induced discoloration of the conjunctiva should therefore be taken into account when a bluish-gray discoloration raises the suspicion of conjunctival melanoma.
- 28 February 2018
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 236 (07) , 877-884
Korrelation der quantitativen Metamorphopsiemessung und der zentralen Netzhautdicke bei diabetischem Makulaödem und altersassoziierter exsudativer Makuladegeneration
Hintergrund Zur Erfassung von Metamorphopsien steht im klinischen Alltag der Amsler-Test zur Verfügung. Dieser erfasst qualitativ Metamorphopsien, zur Quantifizierung von Metamorphopsien und als Verlaufskontrolle wurde der computerbasierte Test „AMD – A Metamorphopsia Detector®“ entwickelt. Das Ziel dieser Studie ist zu untersuchen, ob eine Korrelation zwischen zentraler Netzhautdicke (CRT, gemessen mittels Spectral Domain OCT) und quantifizierter Metamorphopsiemessung bei Patienten mit exsudativer altersassoziierter Makuladegeneration (AMD) und diabetischem Makulaödem (DMÖ) besteht. Material und Methoden 66 Augen von 66 Patienten (DMÖ: 19 [11 Männer, 8 Frauen; Alter 42 – 76 Jahre]; AMD: 47 [13 Männer, 34 Frauen; Alter 56 – 93 Jahre]) wurden in dieser explorativen Pilotstudie untersucht und in Hinblick auf das Vorliegen eines Makulaödems (zentrale 500-µm-Zone, Cirrus HD-OCT) klassifiziert. Bestkorrigierter monokularer Fernvisus (BCVA), Amsler-Test, Metamorphopsiemessung (AMD – A Metamorphopsia Detector) mit Angabe des Metamorphopsie-Index (MI), binokulare Ophthalmoskopie, SD-OCT mit Messung der zentralen Netzhautdicke (CRT) und ggf. Fluoreszenzangiografie wurden durchgeführt. Die Korrelation von CRT und MI wurde mittels Spearman-Korrelation geprüft. Ergebnisse BCVA bei DMÖ bzw. AMD betrug (logMAR) 0,27 (SD 0,3) bzw. 0,29 (SD 0,2). Bei Augen mit DMÖ zeigte sich eine Korrelation von MI und CRT mit rho = 0,88 (p < 0,001) und bei Augen mit AMD betrug rho = 0,56 (p < 0,001). Schlussfolgerung Die Korrelation von CRT und MI war bei DMÖ hoch und bei AMD moderat. Künftige Studien sollen untersuchen, ob sich die Metamorphopsiemessung zur Detektion einer Konversion in eine exsudative AMD eignet und ob dies eine Messung zur Verlaufskontrolle, ggf. als Selbsttest ermöglicht. Background Amsler Test is the standard used to detect metamorphopsia. To develop a tool to quantitatively measure and monitor metamorphopsia, the computer-based test “AMD – A Metamorphopsia Detector®” was developed. This study was performed to examine the correlation of metamorphopsia index (MI) and central retinal thickness (CRT) in exsudative age-related macular degeneration (AMD) and diabetic macular edema (DME). Material and Methods Sixty-six eyes of 66 patients, DME: 19 (11 males, 8 females; age 42 – 76); AMD: 47 (13 male, 34 female; age 56 – 93) were included in this convenient sample study and classified as having or not having macular edema (central 500 µm, Cirrus HD-OCT). Best corrected monocular distance visual acuity (BCVA), Amsler Test, Metamorphopsia Index of AMD – A Metamorphopsia Detector, binocular ophthalmoscopy, central retinal thickness (SD-OCT) and fluorescein angiography, if necessary, were performed. Correlation of central retinal thickness and metamorphopsia index was evaluated by Spearman correlation. Results Mean BCVA (logMAR) was 0.27 (SD 0.3) in DME and 0.29 (SD 0.2) in AMD. Spearmanʼs rho as a measure for correlation between CRT and MI was 0.88 (p < 0.001) in DME and 0.56 (p < 0.001) in AMD. Conclusions Correlation of CRT und MI was high in DME and moderate in AMD. Future studies will examine if metamorphopsia measurement is a feasible tool for detection of conversion into neovascular AMD and for (self-)monitoring.
- 28 February 2018
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 236 (07) , 877-884
Korrelation der quantitativen Metamorphopsiemessung und der zentralen Netzhautdicke bei diabetischem Makulaödem und altersassoziierter exsudativer Makuladegeneration
Hintergrund Zur Erfassung von Metamorphopsien steht im klinischen Alltag der Amsler-Test zur Verfügung. Dieser erfasst qualitativ Metamorphopsien, zur Quantifizierung von Metamorphopsien und als Verlaufskontrolle wurde der computerbasierte Test „AMD – A Metamorphopsia Detector®“ entwickelt. Das Ziel dieser Studie ist zu untersuchen, ob eine Korrelation zwischen zentraler Netzhautdicke (CRT, gemessen mittels Spectral Domain OCT) und quantifizierter Metamorphopsiemessung bei Patienten mit exsudativer altersassoziierter Makuladegeneration (AMD) und diabetischem Makulaödem (DMÖ) besteht. Material und Methoden 66 Augen von 66 Patienten (DMÖ: 19 [11 Männer, 8 Frauen; Alter 42 – 76 Jahre]; AMD: 47 [13 Männer, 34 Frauen; Alter 56 – 93 Jahre]) wurden in dieser explorativen Pilotstudie untersucht und in Hinblick auf das Vorliegen eines Makulaödems (zentrale 500-µm-Zone, Cirrus HD-OCT) klassifiziert. Bestkorrigierter monokularer Fernvisus (BCVA), Amsler-Test, Metamorphopsiemessung (AMD – A Metamorphopsia Detector) mit Angabe des Metamorphopsie-Index (MI), binokulare Ophthalmoskopie, SD-OCT mit Messung der zentralen Netzhautdicke (CRT) und ggf. Fluoreszenzangiografie wurden durchgeführt. Die Korrelation von CRT und MI wurde mittels Spearman-Korrelation geprüft. Ergebnisse BCVA bei DMÖ bzw. AMD betrug (logMAR) 0,27 (SD 0,3) bzw. 0,29 (SD 0,2). Bei Augen mit DMÖ zeigte sich eine Korrelation von MI und CRT mit rho = 0,88 (p < 0,001) und bei Augen mit AMD betrug rho = 0,56 (p < 0,001). Schlussfolgerung Die Korrelation von CRT und MI war bei DMÖ hoch und bei AMD moderat. Künftige Studien sollen untersuchen, ob sich die Metamorphopsiemessung zur Detektion einer Konversion in eine exsudative AMD eignet und ob dies eine Messung zur Verlaufskontrolle, ggf. als Selbsttest ermöglicht. Background Amsler Test is the standard used to detect metamorphopsia. To develop a tool to quantitatively measure and monitor metamorphopsia, the computer-based test “AMD – A Metamorphopsia Detector®” was developed. This study was performed to examine the correlation of metamorphopsia index (MI) and central retinal thickness (CRT) in exsudative age-related macular degeneration (AMD) and diabetic macular edema (DME). Material and Methods Sixty-six eyes of 66 patients, DME: 19 (11 males, 8 females; age 42 – 76); AMD: 47 (13 male, 34 female; age 56 – 93) were included in this convenient sample study and classified as having or not having macular edema (central 500 µm, Cirrus HD-OCT). Best corrected monocular distance visual acuity (BCVA), Amsler Test, Metamorphopsia Index of AMD – A Metamorphopsia Detector, binocular ophthalmoscopy, central retinal thickness (SD-OCT) and fluorescein angiography, if necessary, were performed. Correlation of central retinal thickness and metamorphopsia index was evaluated by Spearman correlation. Results Mean BCVA (logMAR) was 0.27 (SD 0.3) in DME and 0.29 (SD 0.2) in AMD. Spearmanʼs rho as a measure for correlation between CRT and MI was 0.88 (p < 0.001) in DME and 0.56 (p < 0.001) in AMD. Conclusions Correlation of CRT und MI was high in DME and moderate in AMD. Future studies will examine if metamorphopsia measurement is a feasible tool for detection of conversion into neovascular AMD and for (self-)monitoring.