SSStephen Siwila

Stephen Siwila

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stephen Siwila has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Isobel C. Brink

    Stellenbosch University

    4 shared publications
  • Isobel C. Brink

    Department of Civil Engineering, Water Engineering Division, Stellenbosch University, Private Bag X1, Matieland 7602, Cape Town, South Africa

    2 shared publications
  • Choolwe Buumba

    Department of Civil Engineering and Construction, Copperbelt University, P.O. Box 21692, Kitwe, Zambia

    1 shared publication
  • Emmanuel Kapesa

    Department of Civil Engineering and Construction, Copperbelt University, P. O. Box 21692, Kitwe, Zambia

    1 shared publication
  • Isobel C Brink

    Department of Civil Engineering, Water Engineering Division, Stellenbosch University, Private Bag X1, Matieland 7602, Cape Town, South Africa

    1 shared publication

Latest Publications

  • Open Access

    Treatment of domestic greywater using fly ash as an adsorbent incorporated in a slow sand filtration system

    by Stephen Siwila, Emmanuel Kapesa

    This study investigated the use of fly ash for treatment of domestic greywater when incorporated in a small-scale slow sand filtration (SSF) system. The system was designed, constructed, and tested for treating domestic grey water for irrigation purposes. Configuration A of the system contained sand and gravel only, while configuration B contained fly ash, sand, and gravel. The greywater samples used to test the designed system were collected from the student hostels at the Copperbelt University in Zambia. Additionally, physical and chemical characterisation of the fly ash was done and all key characteristics are presented under the results and discussion section. The system that contained fly ash considerably improved the greywater quality for irrigation purposes by reducing turbidity by 95%, colour by 98%, and chloride by 49% and increasing dissolved oxygen by 33%. However, pH, total dissolved solids, and electrical conductivity were observed to be slightly higher in the treated greywater effluent. The slight increase in these parameters is suspected to have been caused by possible leaching from the the fly ash. Therefore, obtaining fly ash from sources that may not cause any increase in the said parameters in the treated effluent is recommended to maintain compliance with irrigation water quality.


  • Open Access

    Investigation of groundwater contamination in relation to septic systems in Kitwe West Township, Kitwe, Zambia

    by Stephen Siwila, Choolwe Buumba

    This study investigated the quality of groundwater with respect to septic systems in Kitwe West township located in the western part of Zambia's Kitwe district. The study area was selected because most households in the township use boreholes and septic systems as sources of drinking water and wastewater disposal facilities respectively. The study showed the presence of total coliforms in 90% of the boreholes while only 30% of the boreholes were contaminated with fecal coliforms rendering the water unsafe for drinking. The study revealed that there was no distinct relationship between distance from borehole to septic tank system and the quality of borehole water. It was however observed that for boreholes within a 15 m proximity to individual home-owned dump sites the level of fecal contamination increased as the distance from the boreholes to the dump sites decreased. The study has vividly shown that the location of boreholes and septic tank systems in the same plot of land exacerbated by the presence of solid waste dump sites in a residential plot that depends on groundwater is not advisable. This is because the safety of groundwater cannot be guaranteed even if technical specifications are followed for boreholes and septic tank systems.


  • Open Access

    Modelling of Escherichia coli removal by a low-cost combined drinking water treatment system

    by Stephen Siwila, Isobel C Brink

    This work presents mathematical modelling of Escherichia coli (E.coli) removal by a multi-barrier point-of-use drinking water system. The modelled system is a combination of three treatment stages: filtration by geotextile fabric followed by filtration and disinfection by silver-coated ceramic granular media (SCCGM) then granular activated carbon (GAC) filtration. The presented models accounted for removal mechanisms by each treatment stage. E.coli was modelled as a microbial particle. E.coli inactivation by SCCGM was modelled using the Chick's, Chick-Watson, Collins-Selleck and complete mix system bacterial inactivation kinetic models, which were considered adequately representative for describing the removal. Geotextile removal was modelled using colloidal filtration theory (CFT) for hydrosol deposition in fibrous media. The filtration removal contributions by the SCCGM and GAC were modelled using CFT for removal of colloidal particles by granular media. The model results showed that inactivation by silver in the SCCGM was the main bacterial removal mechanism. Geotextile and GAC also depicted appreciable removals. The theoretical modelling approach used is important for design and optimization of the multi-barrier system and can support future research in terms of material combinations, system costs, etc. Collector diameter, particle size, filtration velocity and contact time were identified as critical parameters for E.coli removal efficiency.

  • A novel low-cost multi-barrier system for drinking water treatment in rural and suburban areas

    by Stephen Siwila, Isobel C. Brink

    A low-cost multi-barrier drinking water system incorporating geotextile fabric for pre-filtration, silver-coated ceramic granular media (SCCGM) for filtration and disinfection, granular activated carbon (GAC) as an adsorption media and a safe storage compartment for treated water has been developed and tested. The developed system offers a novel concept of point-of-use drinking water treatment in rural and suburban areas of developing countries. The system is primarily aimed at bacterial and aesthetic improvement and has been optimised to produce >99.99% E. coli and fecal coliforms removal. Although particular emphasis was placed on the elimination of bacteria, improvement of the acceptability aspects of water was also given high priority so that users are not motivated to use more appealing but potentially unsafe sources. This paper discusses key system features and contaminant removal performance. A system using SCCGM only was also tested alongside the multi-barrier system. Strengths and weaknesses of the system are also presented. Both the developed and SCCGM only systems consistently provided >99.99% E. coli and fecal coliforms removal at an optimum flow of 2 L/h. The developed system significantly recorded improvements of aesthetic aspects (turbidity, color, taste and odor). Average turbidity removals were 99.2% and 90.2% by the multi-barrier and SCCGM only systems respectively.


  • Drinking water treatment using indigenous wood filters combined with granular activated carbon

    by Stephen Siwila, Isobel C. Brink

    A gravity-driven wood filtration system has been designed, tested and optimized incorporating granular activated carbon (GAC), as an appropriate point-of-use technology for the rural poor. Four systems were assessed in respect of metal, bacteria and particle removal when exposed to polluted river water with and without GAC. These were evaluated using fresh, wet preserved and dry preserved Southern African indigenous wood species. Initially, all filter systems with the following indigenous wood species Combretum erythrophyllum in System 1, Tarchonanthus camphoratus in System 2, Leonotis leonurus in System 3 and Salix mucronata in System 4 did not incorporate GAC. The systems recorded 83.3, 85.4, 94.3 and 57.3% E. coli removals, respectively, for fresh filters. Incorporation of GAC in Systems 1 and 4 showed high potential for significant contaminant removals (>99.9%) . Particulate removals were: 97% TSS (total suspended solids) and 96% turbidity removals by System 1; and 100% TSS and 100% turbidity removals by System 4. Metal removals by the combined systems were noteworthy and in the following order: Fe > Pb > Ni > Al > Zn > Cu > As > Cr > Cd > Mn (with average removals for the first five >90% and the last five >50%). Each combined system consistently met turbidity guidelines (≤5 NTU) and produced water with pleasant esthetic aspects.


  • Comparison of five point-of-use drinking water technologies using a specialized comparison framework

    by Stephen Siwila, Isobel C. Brink

    The three novel and two commercially available low-cost point-of-use (PoU) water treatment technologies were comparatively evaluated using a specialized comparison framework targeted at them. The comparison results and specialized framework have been discussed. The PoU systems were evaluated principally in terms of performance, flow rate and cost per volume of water treated (quantitatively), ease of use, potential acceptability and material availability (qualitatively) with main focus on rural and suburban settings. The three novel systems assessed were developed in an ongoing research project aimed at developing a multibarrier low-cost PoU water treatment system. The comparative evaluation and analysis revealed that the commercially available systems may often produce water free of pathogens (with an apparent 100% removal for E. coli and fecal coliforms) but may not be affordable for application to the poorest groups in much of the developing world. The novel systems, which were principally constructed from local materials, were more affordable, can supply relatively safe water and can be constructed by users with minimal training. Overall, bacterial removal effectiveness, ease of use, flow rate, material availability, cost and acceptability aspects of water were identified as key to potential adoption and sustainability of the evaluated low-cost PoU systems.


  • Open Access

    Low cost drinking water treatment using nonwoven engineered and woven cloth fabrics

    by Stephen Siwila, Isobel C. Brink

    The study investigated two engineered fabrics and five cloth fabrics for low cost drinking water treatment. An optimized fabric filtration method has been developed and tested. Numerical models for predicting particulate removal efficiency have been developed for each fabric as support tool for selecting optimal process configuration. Both engineered fabrics showed better performance and achieved the most effective particulate removal for the highest number of layers used. Sequential filtration was done on eight layers for representative fabrics of each type and recorded higher contaminant removal than one filtration run. Geotextile 1 was better than geotextile 2 in particulate removal and recorded Escherichia coli removals of up to 1.4 log removal value (LRV) for eight-layer normal filtration and 3.0 LRV for four-pot sequential filtration. Brushed cotton was best among the cloth fabrics in particulate removal but performed below expectation in bacterial removal. It recorded E. coli removals of only 0.04 LRV and 0.2 LRV for eight-layer normal filtration and four-pot sequential filtration, respectively. Effluent turbidity decreased exponentially with number of fabric layers, in line with porous media filtration theory. The optimized filtration method produced very clear drinking water of relatively safe quality using geotextile 1. Appropriate disinfection is still recommended to ensure continued water safety.


  • A small-scale low-cost water treatment system for removal of selected heavy metals, bacteria and particles

    by Stephen Siwila, Isobel C. Brink

    Two low-cost sand filtration systems incorporating granular activated carbon (GAC) and non-woven geotextile respectively were assessed for Point-of-Use water treatment. Laboratory scale models were evaluated in respect of selected heavy metals, bacterial and particulate removal when exposed to surface water for five months. System 1 (ISSF-1) incorporated GAC and system 2 (ISSF-2) incorporated non-woven geotextile. Filter-mats were placed on the filter surfaces of both systems. Flow rates ranged between 8 and 15 L/h for longer water contact with the GAC and bio-layer. On average, E.coli removals were 96% and 94%, while fecal coliform removals were 96% and 95%, by ISSF-1 and ISSF-2 respectively. Average TSS removals were 98% and 92%, while turbidity removals were 97% and 91%, by ISSF-1 and ISSF-2 respectively. Average metal removals were: Arsenic (21%), Cadmium (82%), Lead (36%), Iron (65%) and Manganese (94%) by ISSF-1, Arsenic (17%), Cadmium (<LoD), Lead (<LoD), Iron (92%) and Manganese (98%) by ISSF-2. Both models consistently met turbidity guideline (5 NTU) and can remove significant amounts of particles. Both systems can treat the poor-quality water used to provide relatively safe water and could be improved further for heavy metal removal. However, to guarantee continued safe-water supply, supplementary treatment by chlorination is recommended.


  • Comparative analysis of two low cost point-of-use water treatment systems

    by Stephen Siwila, Isobel C Brink

    The study examined two low-cost point-of-use water treatment systems developed in respect of bacterial and particulate removal when exposed to surface water for three months. Bacterial removal efficiency was estimated using E. coli and fecal coliforms, while particulate reduction efficiency was estimated by determining turbidity and total suspended solids (TSS). The systems investigated were the Gift of Water System (GWS) made in USA and the Drip Filter System (DFS) Model-JW-PD-1-70 made in South Africa. The study included seasonal water quality changes. Both systems recorded 100% bacterial removal throughout the study. Although results show that DFS was slightly better in terms of particulate reduction, both systems removed large proportions of particles from the water. On average TSS removals were 89% and 95%, while turbidity removals were 87% and 94%, by GWS and DFS respectively. The treated water from the two systems compared well with good quality tap water supplied to Stellenbosch University. The results show that both systems can treat the poor quality water used to meet the SANS 241 and WHO guidelines with respect to bacterial and suspended solids content.