Durwesh Jhodkar
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Durwesh Jhodkar has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Akhilesh Kumar Choudhary
Department of Mechanical Engineering, National Institute of Technology , Hamirpur, Himachal Pradesh
1 shared publication H. Chelladurai
Department of Mechanical Engineering, PDPM Indian Institute of Information and Technology Design and Manufacturing, Jabalpur, India, 482005
1 shared publicationJ. Ramkumar
Departmentt of Mechanical Engineering, Indian Institute of Technology, Kanpur, India, 208016
1 shared publication- Manoj Kumar
Chemical and Biochemical Processing Division, ICAR—Central Institute for Research on Cotton Technology, Mumbai 400019, India
1 shared publication - Mohamed Mekhemar
Clinic for Conservative Dentistry and Periodontology, School of Dental Medicine, Christian-Albrecht’s University, 24105 Kiel, Germany
1 shared publication - Mohan Singh
College of Agricultural Engineering, Jawaharlal Nehru Krishi Vishwavidyalaya (JNKVV), Jabalpur 482004, Madhya Pradesh, India
1 shared publication
Latest Publications
- Open Access
- 26 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (9) , 3901
Cottonseed Kernel Powder as a Natural Health Supplement: An Approach to Reduce the Gossypol Content and Maximize the Nutritional Benefits
Cottonseed is one of the important by-products of the cotton crop. Researchers claim that cottonseed with less than 0.45% of gossypol is quite good for human consumption and animal feeding because it is a rich source of protein, edible oil, and energy. Total and free gossypols are the influencing parameters that reduce the edible nature of the cottonseed. In the present work, multiple quadratic regression models have been prepared to predict the reduction in the free and total gossypol percent. This response surface method (RSM)-based approach was applied to investigate the combined effect between input parameters such as acetone level, time of extraction, liquid-to-solid ratio (LSR), and the number of extraction cycles, whereas output responses are free and total gossypol reduction percentage. Analysis of Variance (ANOVA) has been performed to determine the highly significant parameter. The optimum combination of input parameters was determined using the RSM-based desirability approach, and confirmatory experiments were performed to validate the combination. Results revealed that the number of extraction cycles and liquid-to-solid ratio significantly affects the reduction of free and total gossypol levels. The values of r-square were found above 0.9, which indicates that the developed models are suitable and reliable for predicting free and total gossypol reduction percentage.
- 26 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (9) , 3901
Open AccessCottonseed Kernel Powder as a Natural Health Supplement: An Approach to Reduce the Gossypol Content and Maximize the Nutritional Benefits
Cottonseed is one of the important by-products of the cotton crop. Researchers claim that cottonseed with less than 0.45% of gossypol is quite good for human consumption and animal feeding because it is a rich source of protein, edible oil, and energy. Total and free gossypols are the influencing parameters that reduce the edible nature of the cottonseed. In the present work, multiple quadratic regression models have been prepared to predict the reduction in the free and total gossypol percent. This response surface method (RSM)-based approach was applied to investigate the combined effect between input parameters such as acetone level, time of extraction, liquid-to-solid ratio (LSR), and the number of extraction cycles, whereas output responses are free and total gossypol reduction percentage. Analysis of Variance (ANOVA) has been performed to determine the highly significant parameter. The optimum combination of input parameters was determined using the RSM-based desirability approach, and confirmatory experiments were performed to validate the combination. Results revealed that the number of extraction cycles and liquid-to-solid ratio significantly affects the reduction of free and total gossypol levels. The values of r-square were found above 0.9, which indicates that the developed models are suitable and reliable for predicting free and total gossypol reduction percentage.
- 20 March 2018
- Published by Taylor & Francis in Journal of Microwave Power and Electromagnetic Energy
- Vol. 52 (2) , 109-127
Comparison of machining performance of microwave post-heated WC insert with dry, wet and MQL cutting in turning operation
This paper describes the application of microwave energy to enhance the machining performance of tungsten carbide tool insert in order to reduce the use of cutting fluids. Application of cutting fluids increases the machining costs, which include fluid consumption, maintenance and disposal costs. Health hazards for workers, environmental issues and economic aspects of cutting fluid motivate researchers to move towards coolant-free machining. This study aimed to minimize the dependency on cutting fluid during machining and to suggest a suitable alternative to improve the performance of tungsten carbide tool insert. Microwave post-treatment of tungsten carbide tool insert is the emerging technique in which the tool insert is subjected to microwave irradiation at a frequency of 2.5 GHz. In the present investigation, turning operations have been performed on AISI 1040 steel (American Iron and Steel Institue) using microwave-treated insert under dry cutting environment and untreated insert using dry, wet and minimum quantity lubrication (MQL) cutting environment. Variation of tool wear and surface roughness has been experimentally investigated in this study to evaluate the machining performance. Tool wear mechanism and chip morphology have been analysed using scan electron microscopy. The results indicate that microwave-treated insert achieved better performance than fresh tungsten carbide (WC/Co) inserts used in dry, wet and MQL cutting conditions.
- 20 March 2018
- Published by Taylor & Francis in Journal of Microwave Power and Electromagnetic Energy
- Vol. 52 (2) , 109-127
Comparison of machining performance of microwave post-heated WC insert with dry, wet and MQL cutting in turning operation
This paper describes the application of microwave energy to enhance the machining performance of tungsten carbide tool insert in order to reduce the use of cutting fluids. Application of cutting fluids increases the machining costs, which include fluid consumption, maintenance and disposal costs. Health hazards for workers, environmental issues and economic aspects of cutting fluid motivate researchers to move towards coolant-free machining. This study aimed to minimize the dependency on cutting fluid during machining and to suggest a suitable alternative to improve the performance of tungsten carbide tool insert. Microwave post-treatment of tungsten carbide tool insert is the emerging technique in which the tool insert is subjected to microwave irradiation at a frequency of 2.5 GHz. In the present investigation, turning operations have been performed on AISI 1040 steel (American Iron and Steel Institue) using microwave-treated insert under dry cutting environment and untreated insert using dry, wet and minimum quantity lubrication (MQL) cutting environment. Variation of tool wear and surface roughness has been experimentally investigated in this study to evaluate the machining performance. Tool wear mechanism and chip morphology have been analysed using scan electron microscopy. The results indicate that microwave-treated insert achieved better performance than fresh tungsten carbide (WC/Co) inserts used in dry, wet and MQL cutting conditions.