Ratthasak Prommas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ratthasak Prommas has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Phadungsak Rattanadecho
2 shared publicationsChaimongkon Chokpanyasuwan
Rattanakosin College for Sustainable Energy and Environment (RCSEE) Rajamangala University of Technology Rattanakosin 96 moo 3 Puthamonthon Sai 5 73170 Salaya Puthamonthon Nakhon Pathom Thailand
1 shared publicationDittha Nonthiworawong
Arch G Tech Co Ltd, 770-25 Soi Patthanakarn 38,Patthanakarn Rd, Bangkok, Thailand
1 shared publicationNoppadol Pringsakul
1 shared publication- Pongsakorn Kachapongkun
Rajamangala University of Technology Rattanakosin
1 shared publication - Prangtip Rittichote Kaewpengkrow1 shared publication
Latest Publications
- 1 January 2024
- Published by Engineered Science Publisher in Engineered Science
A Comparative Analysis of Variables Affecting Heat Gain Through Louvers Shape and Wall by Evaluating the Overall Thermal Transfer Value (OTTV)
Sun Louvers are the building decoration material that protects the building from sunlight and heat from entering the building, which reduces the amount of energy used in the building.
- 1 January 2024
- Published by Engineered Science Publisher in Engineered Science
A Comparative Analysis of Variables Affecting Heat Gain Through Louvers Shape and Wall by Evaluating the Overall Thermal Transfer Value (OTTV)
Sun Louvers are the building decoration material that protects the building from sunlight and heat from entering the building, which reduces the amount of energy used in the building.
- Open Access
- 28 January 2023
- Published by Chiang Mai University in Chiang Mai Journal of Science
- Vol. 50 (1) , 1-14
Analysis of Waste Optical Fiber Cables for Converting to Fuel through Pyrolysis
The aim of this study was to analyze optical fiber cable (OFC) waste as an alternative fuel by using pyrolysis. The optimized conditions were used to assess the feasibility and environmental impact of the pyrolysis of non-used OFCs. In the pyrolysis trial, unused OFC of a single-mode ADSS 24 core (length of 15 cm and weight 5 kg) was subjected to pyrolysis at the temperature range of 300–500 °C for 4 h using a batch reactor. In the pyrolysis trial, maximum amount of oil was obtained during the cyclonic separation step at a pyrolysis temperature of 350 °C, maximum amount of oil was collected during the water-cooling step at 400 °C, and the least amount of char remained at 500 °C. The high heating value of the pyrolysis oil obtained from pyrolyzed OFC was 40–45 MJ/kg. The results revealed that the optimum temperature required for producing maximum amount of pyrolysis oil and minimum char was 350 °C. Moreover, the GC–MS results revealed that the produced pyrolysis oil contained hydrocarbons, carboxylic acid, carbonyl, and aromatic compounds. The pyrolysis products generated from the OFC mainly contained heavy hydrocarbons (C12–C28), which were compatible with diesel-range hydrocarbons. This result demonstrates the presence of highly aliphatic compounds in the pyrolysis oil products and is consistent with the GC-MS results. The results suggest that the liquid product under optimized conditions can potentially be applied as renewable energy, which is an approach to reduce OFC removal by landfilling or incineration.
- 28 January 2023
- Published by Chiang Mai University in Chiang Mai Journal of Science
- Vol. 50 (1) , 1-14
Open AccessAnalysis of Waste Optical Fiber Cables for Converting to Fuel through Pyrolysis
The aim of this study was to analyze optical fiber cable (OFC) waste as an alternative fuel by using pyrolysis. The optimized conditions were used to assess the feasibility and environmental impact of the pyrolysis of non-used OFCs. In the pyrolysis trial, unused OFC of a single-mode ADSS 24 core (length of 15 cm and weight 5 kg) was subjected to pyrolysis at the temperature range of 300–500 °C for 4 h using a batch reactor. In the pyrolysis trial, maximum amount of oil was obtained during the cyclonic separation step at a pyrolysis temperature of 350 °C, maximum amount of oil was collected during the water-cooling step at 400 °C, and the least amount of char remained at 500 °C. The high heating value of the pyrolysis oil obtained from pyrolyzed OFC was 40–45 MJ/kg. The results revealed that the optimum temperature required for producing maximum amount of pyrolysis oil and minimum char was 350 °C. Moreover, the GC–MS results revealed that the produced pyrolysis oil contained hydrocarbons, carboxylic acid, carbonyl, and aromatic compounds. The pyrolysis products generated from the OFC mainly contained heavy hydrocarbons (C12–C28), which were compatible with diesel-range hydrocarbons. This result demonstrates the presence of highly aliphatic compounds in the pyrolysis oil products and is consistent with the GC-MS results. The results suggest that the liquid product under optimized conditions can potentially be applied as renewable energy, which is an approach to reduce OFC removal by landfilling or incineration.
- 26 December 2019
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 37 (4) , 1171-1179
Experimental Investigation of Attic Heat Gain Reduction and Indoor Illuminance Using a Light-Vent Pipe
- 26 December 2019
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 37 (4) , 1171-1179
Experimental Investigation of Attic Heat Gain Reduction and Indoor Illuminance Using a Light-Vent Pipe
- 12 April 2018
- Published by ASME International in Journal of Electrochemical Energy Conversion and Storage
- Vol. 15 (4)
Coefficient of Performance of Battery Running and Charging by Magnet Generator Bedini
In this research study, the performance in battery running and charging of an original circuit design is compared with the performance between the developed DC–DC boost converter running and charging replication circuit design. Bedini generators are a kind of magnetic generator designed by John Bedini on the basis of zero point technology. The generator serves as a self-battery charger. In this study, the two types of circuit design, namely, the original and the replication, are examined in terms of performance in battery running and charging. The DC–DC boost converter offers greater voltage boost capabilities and hence has the potential to enhance step-up power conversions. The novel design was a prototype of the six-pole eight-neodymium magnet generator, which potentially offers free energy and could therefore serve as an alternative means of addressing energy needs when the current nonrenewable fuel sources have been wholly depleted in the future. The coefficient of performance (COP) for the battery performance of both designs is calculated in this study in order to allow comparisons to be drawn. Upon analysis, it is discovered that the DC–DC boost converter circuit is both practical and efficient, offering a high level of step-up power conversion capacity for battery running and charging. The COP of the new system provides a significant increase in COP when compared to the original design.
- 12 April 2018
- Published by ASME International in Journal of Electrochemical Energy Conversion and Storage
- Vol. 15 (4)
Coefficient of Performance of Battery Running and Charging by Magnet Generator Bedini
In this research study, the performance in battery running and charging of an original circuit design is compared with the performance between the developed DC–DC boost converter running and charging replication circuit design. Bedini generators are a kind of magnetic generator designed by John Bedini on the basis of zero point technology. The generator serves as a self-battery charger. In this study, the two types of circuit design, namely, the original and the replication, are examined in terms of performance in battery running and charging. The DC–DC boost converter offers greater voltage boost capabilities and hence has the potential to enhance step-up power conversions. The novel design was a prototype of the six-pole eight-neodymium magnet generator, which potentially offers free energy and could therefore serve as an alternative means of addressing energy needs when the current nonrenewable fuel sources have been wholly depleted in the future. The coefficient of performance (COP) for the battery performance of both designs is calculated in this study in order to allow comparisons to be drawn. Upon analysis, it is discovered that the DC–DC boost converter circuit is both practical and efficient, offering a high level of step-up power conversion capacity for battery running and charging. The COP of the new system provides a significant increase in COP when compared to the original design.
- Open Access
- 1 February 2015
- Published by Science Publications in American Journal of Applied Sciences
- Vol. 12 (2) , 142-154
Ant Colony Optimization for Load Management Based on Load Shifting in the Textile Industry
Ant Colony Optimization for Load Management Based on Load Shifting in the Textile Industry
- 1 February 2015
- Published by Science Publications in American Journal of Applied Sciences
- Vol. 12 (2) , 142-154
Open AccessAnt Colony Optimization for Load Management Based on Load Shifting in the Textile Industry
Ant Colony Optimization for Load Management Based on Load Shifting in the Textile Industry