Dorothy A. Sippo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dorothy A. Sippo has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Constance Dobbins Lehman
Division of Breast Imaging, Department of Radiology, Mass General Brigham, Boston, USA
2 shared publications Geoffrey M. Rutledge
Department of Radiology, Massachusetts General Hospital, Massachusetts General Hospital, Avon Comprehensive Breast Evaluation Center, Wang Ambulatory Care Building, Suite 240, 15 Parkman Street, Boston MA, 02114
2 shared publicationsKristine S. Burk
Department of Radiology, Massachusetts General Hospital, Massachusetts General Hospital, Avon Comprehensive Breast Evaluation Center, Wang Ambulatory Care Building, Suite 240, 15 Parkman Street, Boston MA, 02114
2 shared publications- Sarah Mercaldo
Department of Radiology, Massachusetts General Hospital, 55 Fruit St, WAC 240, Boston, MA 02114
2 shared publications Zoe Guan
Department of Biostatistics, Harvard University T H Chan School of Public Health, Boston, MA
2 shared publicationsAhmet Acar
Istanbul School of Medicine, Istanbul University, Istanbul, Turkey
1 shared publication
Latest Publications
- 15 October 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (3) , 410-420
The Potential Role of Artificial Intelligence in Systematic Follow-Up Recommendation Tracking and Outcome Assessment
- 15 October 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (3) , 410-420
The Potential Role of Artificial Intelligence in Systematic Follow-Up Recommendation Tracking and Outcome Assessment
- 13 March 2023
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 20 (3) , 361-363
The Role of Implementation Science in Harnessing the Potential of Automated Outcomes Feedback for Radiologists
- 13 March 2023
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 20 (3) , 361-363
The Role of Implementation Science in Harnessing the Potential of Automated Outcomes Feedback for Radiologists
- 1 December 2020
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 17 (12) , 1626-1635
The Adoption and Impact on Performance of an Automated Outcomes Feedback Application for Tomosynthesis Screening Mammography
- 1 December 2020
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 17 (12) , 1626-1635
The Adoption and Impact on Performance of an Automated Outcomes Feedback Application for Tomosynthesis Screening Mammography
- Open Access
- 1 May 2020
- Published by Oxford University Press (OUP) in JNCI: Journal of the National Cancer Institute
- Vol. 112 (5) , 489-497
Performance of Breast Cancer Risk-Assessment Models in a Large Mammography Cohort
Background: Several breast cancer risk-assessment models exist. Few studies have evaluated predictive accuracy of multiple models in large screening populations. Methods: We evaluated the performance of the BRCAPRO, Gail, Claus, Breast Cancer Surveillance Consortium (BCSC), and Tyrer-Cuzick models in predicting risk of breast cancer over 6 years among 35 921 women aged 40–84 years who underwent mammography screening at Newton-Wellesley Hospital from 2007 to 2009. We assessed model discrimination using the area under the receiver operating characteristic curve (AUC) and assessed calibration by comparing the ratio of observed-to-expected (O/E) cases. We calculated the square root of the Brier score and positive and negative predictive values of each model. Results: Our results confirmed the good calibration and comparable moderate discrimination of the BRCAPRO, Gail, Tyrer-Cuzick, and BCSC models. The Gail model had slightly better O/E ratio and AUC (O/E = 0.98, 95% confidence interval [CI] = 0.91 to 1.06, AUC = 0.64, 95% CI = 0.61 to 0.65) compared with BRCAPRO (O/E = 0.94, 95% CI = 0.88 to 1.02, AUC = 0.61, 95% CI = 0.59 to 0.63) and Tyrer-Cuzick (version 8, O/E = 0.84, 95% CI = 0.79 to 0.91, AUC = 0.62, 95% 0.60 to 0.64) in the full study population, and the BCSC model had the highest AUC among women with available breast density information (O/E = 0.97, 95% CI = 0.89 to 1.05, AUC = 0.64, 95% CI = 0.62 to 0.66). All models had poorer predictive accuracy for human epidermal growth factor receptor 2 positive and triple-negative breast cancers than hormone receptor positive human epidermal growth factor receptor 2 negative breast cancers. Conclusions: In a large cohort of patients undergoing mammography screening, existing risk prediction models had similar, moderate predictive accuracy and good calibration overall. Models that incorporate additional genetic and nongenetic risk factors and estimate risk of tumor subtypes may further improve breast cancer risk prediction.
- 1 May 2020
- Published by Oxford University Press (OUP) in JNCI: Journal of the National Cancer Institute
- Vol. 112 (5) , 489-497
Open AccessPerformance of Breast Cancer Risk-Assessment Models in a Large Mammography Cohort
Background: Several breast cancer risk-assessment models exist. Few studies have evaluated predictive accuracy of multiple models in large screening populations. Methods: We evaluated the performance of the BRCAPRO, Gail, Claus, Breast Cancer Surveillance Consortium (BCSC), and Tyrer-Cuzick models in predicting risk of breast cancer over 6 years among 35 921 women aged 40–84 years who underwent mammography screening at Newton-Wellesley Hospital from 2007 to 2009. We assessed model discrimination using the area under the receiver operating characteristic curve (AUC) and assessed calibration by comparing the ratio of observed-to-expected (O/E) cases. We calculated the square root of the Brier score and positive and negative predictive values of each model. Results: Our results confirmed the good calibration and comparable moderate discrimination of the BRCAPRO, Gail, Tyrer-Cuzick, and BCSC models. The Gail model had slightly better O/E ratio and AUC (O/E = 0.98, 95% confidence interval [CI] = 0.91 to 1.06, AUC = 0.64, 95% CI = 0.61 to 0.65) compared with BRCAPRO (O/E = 0.94, 95% CI = 0.88 to 1.02, AUC = 0.61, 95% CI = 0.59 to 0.63) and Tyrer-Cuzick (version 8, O/E = 0.84, 95% CI = 0.79 to 0.91, AUC = 0.62, 95% 0.60 to 0.64) in the full study population, and the BCSC model had the highest AUC among women with available breast density information (O/E = 0.97, 95% CI = 0.89 to 1.05, AUC = 0.64, 95% CI = 0.62 to 0.66). All models had poorer predictive accuracy for human epidermal growth factor receptor 2 positive and triple-negative breast cancers than hormone receptor positive human epidermal growth factor receptor 2 negative breast cancers. Conclusions: In a large cohort of patients undergoing mammography screening, existing risk prediction models had similar, moderate predictive accuracy and good calibration overall. Models that incorporate additional genetic and nongenetic risk factors and estimate risk of tumor subtypes may further improve breast cancer risk prediction.
- 1 May 2020
- Published by Elsevier in Academic Radiology
- Vol. 27 (5) , 663-671
Impact of Background Parenchymal Enhancement on Diagnostic Performance in Screening Breast MRI
- 1 May 2020
- Published by Elsevier in Academic Radiology
- Vol. 27 (5) , 663-671
Impact of Background Parenchymal Enhancement on Diagnostic Performance in Screening Breast MRI
- 3 January 2020
- Published by Oxford University Press (OUP) in Journal of Breast Imaging
- Vol. 2 (1) , 36-42
The Effect of Prior Comparison MRI on Interpretive Performance of Screening Breast MRI
To evaluate the effect of prior comparison MRI on interpretive performance of screening breast MRI. After institutional review board approval, all screening breast MRI examinations performed from January 2011 through December 2014 were retrospectively reviewed. Screening performance metrics were estimated and compared for exams with and without a prior comparison MRI, using logistic regression models to adjust for age and screening indication (BRCA mutation or thoracic radiation versus breast cancer history versus high-risk lesion history versus breast cancer family history). Most exams, 4509 (87%), had a prior comparison MRI (incidence round), while 661 (13%) did not (prevalence round). Abnormal interpretation rate (6% vs 20%, P < 0.01), biopsy rate (3% vs 9%, P < 0.01), and false-positive biopsy recommendation rate per 1000 exams (21 vs 71, P < 0.01) were significantly lower in the incidence rounds compared to the prevalence rounds, while specificity was significantly higher (95% vs 81%, P < 0.01). There was no difference in cancer detection rate (CDR) per 1000 exams (12 vs 20, P = 0.1), positive predictive value of biopsies performed (PPV3) (35% vs 23%, P = 0.1), or sensitivity (86% vs 76%, P = 0.4). Presence of a prior comparison significantly improves incidence round screening breast MRI examination performance compared with prevalence round screening. Consideration should be given to updating the BI-RADS breast MRI screening benchmarks and auditing prevalence and incidence round examinations separately.
- 3 January 2020
- Published by Oxford University Press (OUP) in Journal of Breast Imaging
- Vol. 2 (1) , 36-42
The Effect of Prior Comparison MRI on Interpretive Performance of Screening Breast MRI
To evaluate the effect of prior comparison MRI on interpretive performance of screening breast MRI. After institutional review board approval, all screening breast MRI examinations performed from January 2011 through December 2014 were retrospectively reviewed. Screening performance metrics were estimated and compared for exams with and without a prior comparison MRI, using logistic regression models to adjust for age and screening indication (BRCA mutation or thoracic radiation versus breast cancer history versus high-risk lesion history versus breast cancer family history). Most exams, 4509 (87%), had a prior comparison MRI (incidence round), while 661 (13%) did not (prevalence round). Abnormal interpretation rate (6% vs 20%, P < 0.01), biopsy rate (3% vs 9%, P < 0.01), and false-positive biopsy recommendation rate per 1000 exams (21 vs 71, P < 0.01) were significantly lower in the incidence rounds compared to the prevalence rounds, while specificity was significantly higher (95% vs 81%, P < 0.01). There was no difference in cancer detection rate (CDR) per 1000 exams (12 vs 20, P = 0.1), positive predictive value of biopsies performed (PPV3) (35% vs 23%, P = 0.1), or sensitivity (86% vs 76%, P = 0.4). Presence of a prior comparison significantly improves incidence round screening breast MRI examination performance compared with prevalence round screening. Consideration should be given to updating the BI-RADS breast MRI screening benchmarks and auditing prevalence and incidence round examinations separately.
- 1 July 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 292 (1) , 51-59
Performance of Screening Breast MRI across Women with Different Elevated Breast Cancer Risk Indications
This study found no evidence of a difference in screening breast MRI performance between women with BRCA mutation or history of chest radiation, personal history of breast cancer, and personal hist... BackgroundScreening breast MRI is recommended for women with BRCA mutation or a history of chest radiation, but guidelines are equivocal for MRI screening of women with a personal history of breast...
- 1 July 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 292 (1) , 51-59
Performance of Screening Breast MRI across Women with Different Elevated Breast Cancer Risk Indications
This study found no evidence of a difference in screening breast MRI performance between women with BRCA mutation or history of chest radiation, personal history of breast cancer, and personal hist... BackgroundScreening breast MRI is recommended for women with BRCA mutation or a history of chest radiation, but guidelines are equivocal for MRI screening of women with a personal history of breast...
- 20 March 2018
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 31 (5) , 596-603
Proposing New RadLex Terms by Analyzing Free-Text Mammography Reports
After years of development, the RadLex terminology contains a large set of controlled terms for the radiology domain, but gaps still exist. We developed a data-driven approach to discover new terms for RadLex by mining a large corpus of radiology reports using natural language processing (NLP) methods. Our system, developed for mammography, discovers new candidate terms by analyzing noun phrases in free-text reports to extend the mammography part of RadLex. Our NLP system extracts noun phrases from free-text mammography reports and classifies these noun phrases as “Has Candidate RadLex Term” or “Does Not Have Candidate RadLex Term.” We tested the performance of our algorithm using 100 free-text mammography reports. An expert radiologist determined the true positive and true negative RadLex candidate terms. We calculated precision/positive predictive value and recall/sensitivity metrics to judge the system’s performance. Finally, to identify new candidate terms for enhancing RadLex, we applied our NLP method to 270,540 free-text mammography reports obtained from three academic institutions. Our method demonstrated precision/positive predictive value of 0.77 (159/206 terms) and a recall/sensitivity of 0.94 (159/170 terms). The overall accuracy of the system is 0.80 (235/293 terms). When we ran our system on the set of 270,540 reports, it found 31,800 unique noun phrases that are potential candidates for RadLex. Our data-driven approach to mining radiology reports can identify new candidate terms for expanding the breast imaging lexicon portion of RadLex and may be a useful approach for discovering new candidate terms from other radiology domains.
- 20 March 2018
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 31 (5) , 596-603
Proposing New RadLex Terms by Analyzing Free-Text Mammography Reports
After years of development, the RadLex terminology contains a large set of controlled terms for the radiology domain, but gaps still exist. We developed a data-driven approach to discover new terms for RadLex by mining a large corpus of radiology reports using natural language processing (NLP) methods. Our system, developed for mammography, discovers new candidate terms by analyzing noun phrases in free-text reports to extend the mammography part of RadLex. Our NLP system extracts noun phrases from free-text mammography reports and classifies these noun phrases as “Has Candidate RadLex Term” or “Does Not Have Candidate RadLex Term.” We tested the performance of our algorithm using 100 free-text mammography reports. An expert radiologist determined the true positive and true negative RadLex candidate terms. We calculated precision/positive predictive value and recall/sensitivity metrics to judge the system’s performance. Finally, to identify new candidate terms for enhancing RadLex, we applied our NLP method to 270,540 free-text mammography reports obtained from three academic institutions. Our method demonstrated precision/positive predictive value of 0.77 (159/206 terms) and a recall/sensitivity of 0.94 (159/170 terms). The overall accuracy of the system is 0.80 (235/293 terms). When we ran our system on the set of 270,540 reports, it found 31,800 unique noun phrases that are potential candidates for RadLex. Our data-driven approach to mining radiology reports can identify new candidate terms for expanding the breast imaging lexicon portion of RadLex and may be a useful approach for discovering new candidate terms from other radiology domains.
- 24 September 2016
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 14 (4) , 517-520
Quality Improvement of Breast MRI Reports With Standardized Templates for Structured Reporting
- 24 September 2016
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 14 (4) , 517-520
Quality Improvement of Breast MRI Reports With Standardized Templates for Structured Reporting