H. Maarten Heres
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
H. Maarten Heres has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Frans N. van de Vosse
Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
2 shared publications B. C. Y. Tchang
Cardiovascular Biomechanics Group, department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
1 shared publicationH. M. C. Kemps
Department of Cardiology, Máxima Medical Centre, Veldhoven, The Netherlands
1 shared publicationM. C. M. Rutten
Cardiovascular Biomechanics Group, department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
1 shared publicationMarc R. H. M. van Sambeek
Department of Vascular Surgery, Catharina Hospital Eindhoven, Michelangelolaan 2, Eindhoven and Netherlands, 5623 EJ
1 shared publicationMarcel C. M. Rutten
Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, 5612 AJ and Netherlands
1 shared publication
Latest Publications
- 22 March 2018
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 118 (6) , 1209-1219
Perfusion dynamics assessment with Power Doppler ultrasound in skeletal muscle during maximal and submaximal cycling exercise
Assessment of limitations in the perfusion dynamics of skeletal muscle may provide insight in the pathophysiology of exercise intolerance in, e.g., heart failure patients. Power doppler ultrasound (PDUS) has been recognized as a sensitive tool for the detection of muscle blood flow. In this volunteer study (N = 30), a method is demonstrated for perfusion measurements in the vastus lateralis muscle, with PDUS, during standardized cycling exercise protocols, and the test–retest reliability has been investigated.
- 22 March 2018
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 118 (6) , 1209-1219
Perfusion dynamics assessment with Power Doppler ultrasound in skeletal muscle during maximal and submaximal cycling exercise
Assessment of limitations in the perfusion dynamics of skeletal muscle may provide insight in the pathophysiology of exercise intolerance in, e.g., heart failure patients. Power doppler ultrasound (PDUS) has been recognized as a sensitive tool for the detection of muscle blood flow. In this volunteer study (N = 30), a method is demonstrated for perfusion measurements in the vastus lateralis muscle, with PDUS, during standardized cycling exercise protocols, and the test–retest reliability has been investigated.
- 12 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (3) , 440-447
Investigation on the Effect of Spatial Compounding on Photoacoustic Images of Carotid Plaques in the In Vivo Available Rotational Range
Photoacoustic imaging (PA) is a promising imaging modality due to its high optical specificity. However, the low signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of in vivo PA images are major challenges that prevent PA imaging from finding its place in clinics. This study investigates the merit of spatial compounding of PA images in arterial phantoms and the achievable improvements of SNR when in vivo conditions are mimicked. The analysis of the compounding technique was performed on a polyvinyl alcohol vessel phantom with black threads embedded in its wall. The in vivo conditions were mimicked by limiting the rotation range in ± 30°, adding turbid surrounding medium, and filling the lumen with porcine blood. Finally, the performance of the technique was evaluated in ex vivo human carotid plaque samples. Results showed that spatial compounding elevates the SNR by 5 to 10 dB and CNR by 1 to 5, depending on the location of the absorbers. This study elucidates prospective in vivo PA characterization of carotid plaques by proposing a method to enhance PA image quality.
- 12 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (3) , 440-447
Investigation on the Effect of Spatial Compounding on Photoacoustic Images of Carotid Plaques in the In Vivo Available Rotational Range
Photoacoustic imaging (PA) is a promising imaging modality due to its high optical specificity. However, the low signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of in vivo PA images are major challenges that prevent PA imaging from finding its place in clinics. This study investigates the merit of spatial compounding of PA images in arterial phantoms and the achievable improvements of SNR when in vivo conditions are mimicked. The analysis of the compounding technique was performed on a polyvinyl alcohol vessel phantom with black threads embedded in its wall. The in vivo conditions were mimicked by limiting the rotation range in ± 30°, adding turbid surrounding medium, and filling the lumen with porcine blood. Finally, the performance of the technique was evaluated in ex vivo human carotid plaque samples. Results showed that spatial compounding elevates the SNR by 5 to 10 dB and CNR by 1 to 5, depending on the location of the absorbers. This study elucidates prospective in vivo PA characterization of carotid plaques by proposing a method to enhance PA image quality.