CCConnor P. Callaway

Connor P. Callaway

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Connor P. Callaway has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Kayla Hendrickson

    Computational NanoBio Technology Laboratory, School of Materials Science and Engineering, Georgia Institute of Technology, 771 Ferst Drive NW, Atlanta, GA, 30332-0245, USA

    1 shared publication
  • Nicholas Bond

    Computational NanoBio Technology Laboratory, School of Materials Science and Engineering, Georgia Institute of Technology, 771 Ferst Drive NW, Atlanta, GA, 30332-0245, USA

    1 shared publication
  • Parveen Sood

    Computational NanoBio Technology Laboratory, School of Materials Science and Engineering, Georgia Institute of Technology, 771 Ferst Drive NW, Atlanta, GA, 30332-0245, USA

    1 shared publication
  • Seung Min Lee

    Computational NanoBio Technology Laboratory, School of Materials Science and Engineering, Georgia Institute of Technology, 771 Ferst Drive NW, Atlanta, GA, 30332-0245, USA

    1 shared publication
  • Seung Soon Jang

    Georgia Institute of Technology 771 Ferst Drive NW

    1 shared publication

Latest Publications

  • Molecular Modeling Approach to Determine the Flory‐Huggins Interaction Parameter for Polymer Miscibility Analysis

    by Connor P. Callaway, Kayla Hendrickson, Nicholas Bond, Seung Min Lee, Parveen Sood, Seung Soon Jang

    In this work, we present a thorough procedure for estimating the Flory‐Huggins χ‐parameter for use in atomistic and mesoscale molecular simulations in computational materials science. In particular, we propose improvements upon traditional Flory‐Huggins theory by implementing a Connolly volume normalization (CVN). We apply this technique to several test systems, including a blend of poly (epichlorohydrin) and poly (methyl acrylate), a blend of polyethylene glycol and poly (methyl methacrylate), a blend of polystyrene and deuterated polystyrene, and three molecular‐weight variants (monomer, dimer, and trimer) of a triblock copolymer for use in multicompartment micelle applications. Our results demonstrate that the newly developed procedure offers high accuracy and efficiency in predicting the Flory‐Huggins χ‐parameter for miscibility analysis compared to traditional experimental and computational methods. There are still several factors that cause the magnitude of the χ‐parameter to vary between simulations performed on molecular species with the same identity but different degrees of polymerization; although we discuss possible explanations for these factors, this is nonetheless a primary focus for further exploration into this new methodology.